Laserfiche WebLink
Product Bosch IDS:1 <br /> BOV860-18-BVA2.060 ForCooling <br /> r � <br /> Tc 38.9 39.4 40.4 40.9 40.2 40.8 41.3 41.7 42.9 43.5 44.0 44.5 / 51.0 51.4 52.4 <br /> 65 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 2.16 2.19 2.22 2.22 2.24 2.26 2.28 2.30 2.36 2.39 2.41 2.43 / 2.94 2.97 2.99 <br /> TC 38.7 39.2 40.2 40.6 40.0 40.5 41.1 41.5 42.6 43.2 43.6 44.2 / 50.8 51.2 51.7 <br /> 75 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 2.43 2.45 2.48 2.48 2.48 2.51 2.53 2.55 2.59 2.61 2.64 2.67 / 3.07 3.10 3.12 <br /> TC 38.3 38.8 39.8 40.2 39.6 40.1 40.6 41.1 42.2 42.8 43.1 43.8 / 50.5 50.9 51.3 <br /> 85 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> 1160 kW 2.71 2.73 2.76 2.76 2.76 2.78 2.81 2.83 2.89 2.91 2.93 2.94 / 3.44 3.47 3.49 <br /> TC 37.9 38.4 39.0 39.4 39.2 39.6 40.1 40.5 41.8 42.2 42.5 42.9 / 49.7 50.1 50.5 <br /> 95 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 3.09 3.12 3.13 3.15 3.15 3.18 3.21 3.22 3.28 3.31 3.34 3.36 / 4.11 4.14 4.17 <br /> TC 37.3 37.8 38.6 39.0 3B.6 39.0 39.4 39.8 41.3 41.7 42.1 42.6 / 48.8 49.2 49.5 <br /> 105 S/T 0.85 0.95 0.98 1.00 0.64 0.83 0.97 0.98 0.44 0.61 0.76 0.92 / 0.38 0.57 0.72 <br /> kW 3.48 3.51 3.55 3.56 3.55 3.58 3.63 3.65 3.68 3.71 3.73 3.76 / 4.49 4.52 4.57 <br /> TC 36.2 36.6 37.4 37.8 37.4 37.8 38.3 38.7 40.1 40.4 40.8 41.1 / 42.2 42.4 42.7 <br /> 115 S/T 0.86 0.96 0.99 1.00 0.65 0.85 0.98 0.99 0.45 0.62 0.78 0.97 / 0.40 0.59 0.74 <br /> kW 4.41 4.45 4.49 4.49 4.49 4.54 4.58 4.60 4.70 4.74 4.76 4.79 / 4.88 4.90 4.91 <br /> TC 41.5 42.1 43.1 43.6 43.1 43.6 44.1 44.6 46.1 46.5 46.9 47.3 / 54.9 55.2 55.6 <br /> 65 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 2.80 2.83 2.86 2.86 2.85 2.87 2.89 2.92 3.06 3.08 3.11 3.14 / 3.37 3.40 3.43 <br /> TC 41.4 41.9 42.9 43.3 43.1 43.6 44.2 44.8 46.1 46.9 47.4 47.7 / 54.5 54.8 55.2 <br /> 75 S/T 0.63 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 2.96 2.98 3.02 3.02 3.01 3.03 3.06 3.08 3.23 3.25 3.28 3.31 / 3.58 3.61 3.64 <br /> TC 41.1 41.6 42.5 43.0 43.0 43.5 44.0 44.7 46.0 46.7 47.2 47.5 / 54.0 54.4 54.8 <br /> 85 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> 1320 kW 3.30 3.33 3.35 3.37 3.36 3.38 3.41 3.44 3.55 3.57 3.59 3.62 / 3.90 3.93 3.96 <br /> (Low Stage) TC 40.6 41.2 42.2 42.6 42.9 43.3 44.0 44.6 45.7 46.5 47.0 47.5 / 53.6 54.0 54.4 <br /> 95 S/T 0.83 0.94 0.97 1.00 0.62 0.81 0.96 0.97 0.42 0.60 0.75 0.90 / 0.37 0.55 0.70 <br /> kW 3.56 3.59 3.61 3.63 3.65 3.66 3.69 3.71 3.73 3.76 3.79 3.82 / 4.43 4.47 4.50 <br /> TC 39.8 40.4 41.2 41.6 41.2 41.7 42.2 42.6 44.1 44.6 45.0 45.3 / 50.8 51.1 51.4 <br /> 105 S/T 0.85 0.95 0.98 1.00 0.64 0.83 0.97 0.98 0.44 0.61 0.76 0.92 / 0.38 0.57 0.72 <br /> kW 4.08 4.12 4.15 4.17 4.16 4.20 4.25 4.28 4.30 4.34 4.36 4.39 / 4.87 4.91 4.94 <br /> TC 36.8 37.2 38.1 38.5 38.4 38.8 39.3 39.7 40.6 40.9 41.2 41.6 / 42.8 43.0 43.2 <br /> 115 S/T 0.66 0.96 0.99 1.00 0.65 0.85 0.97 0.99 0.45 0.62 0.78 0.97 / 0.40 0.59 0.74 <br /> kW 4.51 4.55 4.61 4.61 4.60 4.64 4.70 4.73 4.89 4.90 4.91 4.93 / 5.06 5.07 5.09 <br /> TC 47.7 48.2 49.1 49.6 50.2 50.7 51.3 51.8 53.7 54.1 54.5 54.9 / 60.4 60.9 61.3 <br /> 65 S/T 0.84 0.95 0.98 1.00 0.63 0.82 0.97 0.98 0.43 0.61 0.76 0.91 / 0.39 0.57 0.72 <br /> kW 3.30 3.32 3.35 3.35 3.45 3.48 3.51 3.53 3.53 3.56 3.59 3.62 / 3.73 3.77 3.80 <br /> TO 47.1 47.7 48.7 49.2 50.0 50.6 51.1 51.6 53.5 54.0 54.3 54.7 / 59.8 60.2 60.6 <br /> 75 S/T 0.84 0.95 0.98 1.00 0.63 0.82 0.97 0.98 0.43 0.61 0.76 0.91 / 0.39 0.57 0.72 <br /> kW 3.60 3.63 3.67 3.67 3.66 3.69 3.72 3.75 3.77 3.79 3.81 3.83 / 4.03 4.06 4.10 <br /> TC 46.8 47.3 48.2 48.7 49.4 49.9 50.4 50.9 52.6 53.2 53.8 54.2 / 58.8 59.3 59.7 <br /> 85 S/T 0.84 0.95 0.98 1.00 0.63 0.82 0.97 0.98 0.43 0.61 0.76 0.91 / 0.39 0.57 0.72 <br /> 1520 kW 4.04 4.06 4.08 4.10 4.10 4.14 4.17 4.20 4.27 4.30 4.32 4.35 / 4.54 4.58 4.60 <br /> TC 45.6 46.3 47.2 47.9 48.9 49.5 50.0 50.5 52.2 52.8 53.4 54.1 / 57.3 57.7 58.1 <br /> 95 S/r 0.84 0.95 0.98 1.00 0.63 0.82 0.97 0.98 0.43 0.61 0.76 0.91 / 0.39 0.57 0.72 <br /> kW 4.41 4.45 4.50 4.50 4.51 4.53 4.54 4.56 4.65 4.67 4.69 4.71 / 5.01 5.04 5.07 <br /> TC 43.8 44.3 45.3 45.8 45.7 46.3 46.9 47.4 48.2 48.5 48.9 49.2 / 53.2 53.4 53.4 <br /> 105 S/T 0.86 0.96 0.99 1.00 0.65 0.84 0.98 0.99 0.45 0.62 0.77 0.93 / 0.40 0.59 0.74 <br /> kW 4.71 4.76 4.78 4.80 4.81 4.85 4.90 4.94 4.96 5.00 5.04 5.07 / 5.51 5.53 5.53 <br /> TC 37.4 37.8 38.6 39.1 38.9 39.4 39.8 40.2 41.3 41.8 42.2 42.5 / 43.5 43.8 44.0 <br /> 115 S/T 0.87 0.97 1.00 1.00 0.66 0.86 0.99 1.00 0.46 0.63 0.79 0.98 / 0.42 0.61 0.76 <br /> kW 4.65 4.70 4.74 4.76 4.84 4.86 4.90 4.95 5.08 5.10 5.12 5.12 / 5.16 5.17 5.19 <br /> TC 49.8 50.6 51.7 52.3 53.0 53.6 54.2 54.7 56.1 56.5 56.9 57.3 / 62.3 62.6 62.9 <br /> 65 S/T 0.85 0.96 0.99 1.00 0.64 0.83 0.98 0.99 0.44 0.62 0.77 0.92 / 0.41 0.59 0.74 <br /> kW 3.46 3.49 3.51 3.52 3.53 3.56 3.59 3.62 3.67 3.70 3.73 3.76 / 4.10 4.13 4.17 <br /> TC 49.6 50.1 51.3 51.8 52.8 53.3 53.9 54.5 55.9 56.3 56.7 57.1 / 61.7 62.1 62.4 <br /> 75 S/T 0.85 0.96 0.99 1.00 0.64 0.83 0.98 0.99 0.44 0.62 0.77 0.92 / 0.41 0.59 0.74 <br /> kW 3.74 3.77 3.82 3.82 3.81 3.84 3.87 3.91 3.93 3.96 3.97 4.00 / 4.23 4.27 4.28 <br /> TC 49.4 50.0 51.1 51.6 52.7 53.2 53.8 54.4 55.7 56.3 56.6 57.1 / 61.1 61.5 61.8 <br /> 85 S/T 0.85 0.96 0.99 1.00 0.64 0.83 0.98 0.99 0.44 0.62 0.77 0.92 / 0.41 0.59 0.74 <br /> 1750 kW 4.23 4.25 4.28 4.30 4.40 4.44 4.48 4.51 4.53 4.55 4.59 4.62 / 4.75 4.79 4.82 <br /> (High Stage) TC 49.0 49.6 50.4 51.3 52.6 53.2 53.7 54.2 55.7 56.3 56.5 57.0 / 60.2 60.6 60.9 <br /> 95 S/T 0.85 0.96 0.99 1.00 0.64 0.83 0.98 0.99 0.44 0.62 0.77 0.92 / 0.41 0.59 0.74 <br /> kW 4.63 4.68 4.72 4.75 4.72 4.77 4.81 4.85 4.97 5.01 5.03 5.06 / 5.34 5.38 5.41 <br /> TC 44.6 45.1 46.2 46.7 48.3 48.8 49.3 49.9 51.8 52.2 52.5 52.8 / 54.5 54.8 55.1 <br /> 105 S/T 0.87 0.97 1.00 1.00 0.66 0.85 0.99 1.00 0.46 0.63 0.78 0.94 / 0.42 0.61 0.76 <br /> kW 5.02 5.07 5.11 5.13 5.23 5.28 5.33 5.38 5.41 5.45 5.48 5.51 / 5.67 5.68 5.69 <br /> TC 39.0 39.4 40.3 40.7 40.3 40.7 41.2 41.7 43.4 43.7 43.9 44.2 / 45.3 45.4 45.6 <br /> 115 S/T 0.88 0.98 1.00 1.00 0.67 0.87 1.00 1.00 0.47 0.64 0.80 0.99 / 0.44 0.63 0.78 <br /> kW 4.78 4.82 4.84 4.87 4.92 4.97 5.01 5.06 5.17 5.19 5.21 5.22 / 5.34 5.35 5.36 <br /> TC 52.2 52.8 53.5 54.3 54.4 54.9 55.5 56.1 58.0 58.3 58.7 59.1 / 64.1 64.5 64.9 <br /> 65 S/T 0.86 0.97 1.00 1.00 0.65 0.84 0.99 1.00 0.45 0.63 0.78 0.93 / 0.42 0.60 0.75 <br /> kW 3.68 3.71 3.74 3.74 3.74 3.78 3.81 3.85 3.85 3.88 3.91 3.95 / 4.36 4.39 4.42 <br /> Tc 51.7 52.5 53.4 54.0 54.1 54.7 55.3 55.9 58.1 58.5 58.9 59.3 / 63.6 64.0 64.5 <br /> 75 S/T 0.86 0.97 1.00 1.00 0.65 0.84 0.99 1.00 0.45 0.63 0.78 0.93 / 0.42 0.60 0.75 <br /> kW 3.97 4.01 4.05 4.05 4.04 4.08 4.11 4.15 4.18 4.20 4.22 4.25 / 4.60 4.63 4.66 <br /> TC 50.9 51.5 52.5 53.1 53.3 53.8 54.4 55.0 57.0 57.4 57.8 58.4 / 62.6 63.0 63.3 <br /> 85 S/T 0.86 0.97 1.00 1.00 0.65 0.84 0.99 1.00 0.45 0.63 0.78 0.93 / 0.42 0.60 0.75 <br /> 1880 kW 4.43 4.47 4.51 4.51 4.53 4.55 4.59 4.63 4.65 4.68 4.71 4.74 / 5.05 5.08 5.11 <br /> Tc 49.8 50.3 51.5 52.0 53.0 53.5 54.1 54.7 56.8 57.2 57.5 57.8 / 61.2 61.6 61.9 <br /> 95 S/T 0.86 0.97 1.00 1.00 0.65 0.84 0.99 1.00 0.45 0.63 0.78 0.93 / 0.42 0.60 0.75 <br /> kW 4.71 4.76 4.78 4.80 4.75 4.80 4.85 4.89 5.03 5.06 5.09 5.12 / 5.41 5.44 5.48 <br /> TC 45.9 46.4 47.5 48.0 50.4 50.9 51.5 52.0 54.1 54.4 54.7 55.1 / 55.6 55.8 56.1 <br /> 105 S/T 0.88 0.97 1.00 1.00 0.67 0.86 1.00 1.00 0.47 0.64 0.79 0.95 / 0.43 0.62 0.77 <br /> kW 5.16 5.21 5.25 5.27 5.38 5.43 5.49 5.54 5.58 5.61 5.65 5.68 / 5.71 6.72 5.74 <br /> TC 39.8 40.2 40.8 41.3 40.8 41.3 41.7 42.2 43.9 44.3 44.5 44.7 / 46.0 46.2 46.3 <br /> 115 S/T 0.89 0.98 1.00 1.00 0.68 0.88 1.00 1.00 0.48 0.65 0.81 1.00 / 0.45 0.64 0.79 <br /> kW 4.92 4.95 4.98 5.00 1 5.04 5.11 5.16 5.21 5.28 5.29 5.31 5.32 5.42 5.43 5.45 <br /> Table 14 <br /> TC refer to total capacity S/T.refer to the ratio of sensible heat and total capacity M refer to total Input power <br /> Bosch Thermotechnology Corp.112.2020 Data subject to change <br /> f. <br /> 1 <br />