My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7720 HARDESON RD K & H PRINTING 2025-01-31
>
Address Records
>
HARDESON RD
>
7720
>
K & H PRINTING
>
7720 HARDESON RD K & H PRINTING 2025-01-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2025 2:32:28 PM
Creation date
1/28/2025 10:51:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HARDESON RD
Street Number
7720
Tenant Name
K & H PRINTING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
247
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tqC0 Fire & Buildings <br /> Products <br /> Technical Services: Tel: (800) 381-9312/ Fax: (800)791-5500 <br /> Model BFV-N Butterfly Valve <br /> Wafer Style <br /> 21nch - 12 Inch (DN50 - DN300) <br /> General Technical <br /> Description Data ' <br /> The Model BFV-N Wafer Style Butter- Model <br /> fly Valves (Ref. Figure 1) are indicat- BFV-N <br /> ing type valves designed for use in fire Sizes:ANSI Inches/DN <br /> protection systems where a visual in- 2 (DN50), 2-1/2(DN65), 3 (DN80), <br /> dication is required as to whether the 4(DN100), 5(DN125), 6(DN150), <br /> valve is open or closed.They are used, 8(DN200), 10(DN250), 12 (DN300) <br /> for example, as system, sectional, and Approvals <br /> pump water control valves. They are The 2 through 12 inch (DN50 - DN300) <br /> suitable for installation between ANSI Model BFV-N Wafer Style Butterfly <br /> Class 125 or 150 flanges without the Valves are UL and C-UL Listed and FM <br /> need for flange gaskets. Approved. <br /> For applications requiring supervision In addition, the Model BFV-N Wafer <br /> of the open position of the valve, the Style Butterfly Valves are listed by the <br /> Gear Operators for the Model BFV-N California State Fire Marshall under <br /> Butterfly Valves are provided with Listing No.7770-1670:101. <br /> two sets of factory installed internal <br /> switches each having SPDT contacts. All laboratory listings and approvals are <br /> The supervisory switches transfer their for indoor and outdoor use. Friction Loss <br /> electrical contacts when there is move- Maximum Working Pressure The approximate friction loss, based <br /> ment from the valve's normal open po- 250 psi (17,2) bar on the Hazen Williams formula and ex- <br /> sition during the first two revolutions of Materials of Construction: pressed in equivalent length of pipe <br /> the handwheel. Body with C= 120, is as follows. Unless oth- <br /> WARNINGS Ductile iron conforming to ASTM A-536 erwise indicated, the data is based on <br /> The Model BFV-N Wafer Style Butter- Disc friction loss information collected at a <br /> flyValves described herein must be in- typical flow rate of 15 feet per second. <br /> Ductile iron conforming to ASTM A-395, .4.4 feet of 2 inch Sch. 40 pipe for <br /> stalled and maintained in compliance Nickel Plated <br /> with this document, as well as with the the 2 inch valve. <br /> applicable standards of the National Seat Material • 6.2 feet of 2-1/2 inch Sch. 40 pipe <br /> Fire Protection Association, in addition Grade EPDM "E" rubber conforming for the 2-1/2 inch valve. <br /> to the standards of any other authori- to ASTM D-2000 • 7.6 feet of 3 inch Sch. 40 pipe for <br /> ties having jurisdiction. Failure to do Upper Stem the 3 inch valve. <br /> so may impair the performance of Type 416 Stainless Steel conforming •9.2 feet of 4 inch Sch. 40 pipe for <br /> these devices. to ASTM 582 the 4 inch valve. <br /> The owner is responsible for maintain- Operator •9.0 feet* of 5 inch Sch. 40 pipe for <br /> ing their fire protection system and de- Gear operator with iron housing the 5 inch valve. <br /> vices in proper operating condition. • 8.2 feet of 6 inch Sch. 40 pipe for <br /> The installing contractor or sprinkler the 6 inch valve. <br /> manufacturer should be contacted • 12.7 feet*of 8 inch Sch.30 pipe for <br /> with any questions. the 8 inch valve. <br /> •20.1 feet*of 10 inch Sch.30 pipe <br /> for the 10 inch valve. <br /> •22.3 feet* of 12 inch Sch. 30 pipe <br /> for the 12 inch valve. <br /> *NFPA 13 <br /> Page 1 of 4 MAY, 2007 TFP1515 <br />
The URL can be used to link to this page
Your browser does not support the video tag.