TFP1515 Page 3 of 4 <br /> Installation <br /> The BFV-N Wafer Style Butterfly Valves F- — — — — — — <br /> may be installed with flow in either di- SUPERVISORY <br /> rection and can be positioned either I I SWITCH <br /> horizontally or vertically. They are de- <br /> signed for installation between the fac- I SWITCH SHOWN <br /> es of ANSI Class 125 and 150 flanges. L _J WITH VALVE <br /> —The Series BFV-N are self-sealing be- - FULL OPEN <br /> tween mating flanges; therefore, they o o <br /> do not require the use of additional z z <br /> gaskets. r i 0 0 <br /> The BFV-N may be installed with any <br /> pressure class or schedule of pipe or <br /> tubing no greater than schedule 40 that END OF LINE PANEL <br /> is listed or approved for fire protection RESISTOR <br /> service and installed in accordance <br /> with the manufacturers instructions. <br /> The wafer bodies have locating lugs to F <br /> ensure proper centering of the valve AUXILIARY <br /> body when flange bolts are installed. I G 40 ND I SWITCH <br /> Refer to Figure 1 for bolt diameter. <br /> Bolts and studs must meet the mini- SWITCH SHOWN <br /> mum strength requirements of ASTM L _ xe <br /> _J WITH VALVE <br /> A307 (Grade B), and the nuts must FULL OPEN <br /> meet the minimum strength require- w J <br /> ments of ASTM A563(Grade A). 0 °-° m o <br /> Prior to installation, close the valve. Z <br /> Spread the flanges apart to allow the - <br /> valve to slip easily between the flang- <br /> es. Make sure the pipe flange faces POWER + <br /> are clean of any foreign material such <br /> as scale, metal shavings, or weld- <br /> ing slag. Insert the valve between the <br /> flanges (without flange gaskets). Do <br /> not apply lubricant to the seat faces <br /> as this may damage the seat materi- CONTACT RATING .... 1/2A @ 125 VDC <br /> al. Be sure to center the valve and do 1/4A @ 250 VDC <br /> not damage the liner. Relax the sepa- 15.1A/12HP @ 125,250 VAC <br /> ration of the flanges, install, and hand- 5A @ 125 VAC 1" <br /> tighten all flange bolts. Slowly open <br /> the valve, checking for free movement FIGURE 2 <br /> of the disc. If valve opens freely, leave MODEL BFV-N BUTTERFLY VALVE <br /> the valve in the open position, and us- -INTERNAL SWITCH WIRING DIAGRAM- <br /> ing a cross-draw sequence, tighten all <br /> flange bolts until the valve is metal-to- <br /> metal with both mating flanges. Rec- <br /> ommended tightening torques are list- NOTE <br /> ed in Table 1. For outdoor applications with inter- Nominal Recommended <br /> Flange Size Minimum Torque <br /> Be certain to keep flange faces as par- nal supervisory switches, it is recom- <br /> allel as possible during and after tight- mended that wiring connections be ANSI Inches Ft. Lbs <br /> ening bolts or studs. After final tight- made at a temperature above 150F DN (Nm) <br /> ening, again check the valve for full (-9°C), in order to insure sufficient flex- 2-4 20-30 <br /> opening and closing. ibility of the wire lead insulation. DN50- DN100 (27,1 -40,7) <br /> As applicable, refer to Figure 2 for the 5-8 33-50 <br /> internal switch wiring diagram. DN125- DN200 (44,7-67,8) <br /> Conduit and electrical connections 10 53-75 <br /> are to be made in accordance with DN250 (71,8- 101,7) <br /> the authority having jurisdiction and/ <br /> or the National Electrical Code. With 12 80- 110 <br /> reference to Figure 2,the"supervisory DN300 (108,4- 149,1) <br /> switch" is intended for connection to <br /> the supervisory circuit of a fire alarm TABLE 1 <br /> control panel in accordance with NFPA RECOMMENDED TORQUES <br /> 72. The "auxiliary switch" is intend- <br /> ed for the unsupervised connection <br /> to auxiliary equipment in accordance <br /> with NFPA 70, National Electric Code. <br />