3003 W CASINO RD BASE FILE 2025-01-31
>
Address Records
>
W CASINO RD
>
3003
>
BASE FILE
>
3003 W CASINO RD BASE FILE 2025-01-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2025 1:29:09 PM
Creation date
1/28/2025 11:40:42 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
271
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 4 of 8 <br /> R QUICK RESPONSE <br /> NJIKJNG4 DRY HORIZONTAL <br /> SIDEWALL SPRINKLERS <br /> The Viking Corporation,210 N Industrial Park Drive, Hastings MI 49058 <br /> Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br /> Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com <br /> Approval Chart 1 (UL) Temperature <br /> Quick Response Dry Horizontal Sidewall Sprinklers Finish KEY <br /> For Light Hazard Occupancies Only A1XF Escutcheon(ifapplicable) <br /> Maximum 175 PSI (12 bar)WWP <br /> Sprinkler Base Thread Size Nominal Order Length Listings and Approvals° <br /> Part No.' SIN Style K-FactorZ Increment (Refer also to Design Criteria on page 106e.) <br /> NPT BSPT U.S. metric' Inches mm cULus' NYC6 VdS LPCB C E 0 <br /> 08384U Adjustable 1" -- 5.6 80.6 1/2" 12.7 A1,A5 Al -- -- -- - <br /> 16458U VK178 Standard -- 25 mm -- 80.6 1/2" 12.7 Al,A5 <br /> 08386U VK182 Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- - <br /> 16454U Recessed -- 25 mm 80.6 1/4" 6.35 B2, B6 - -- -- <br /> 08388U 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- - <br /> 16456U VK174 Plain Barrel 25 mm -- 80.6 1/2" 12.7 A3 <br /> Approved Finishes and "A" Dimensions <br /> 1* - Chrome, or White Polyester' sprinkler with a Chrome, Brass, or White Polyester Sleeve and <br /> Escutcheon with "A"dimensions 1-1/2"to 45-1/2"(38.1 mm to 1,156 mm) <br /> Approved Temperature Ratings 2*-Chrome, or White Polyester'with "A"dimensions 3-1/4"to 47-1/2"(82.5 mm to 1,207 mm) <br /> A- 155 OF (68 °C), 175 OF (79-C), 200 OF 3-Chrome, Brass,White Polyester',or ENT'with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) <br /> (93 °C), and 286 OF(141 °C) 4-Chrome or Brass with"A"dimensions 3"to 47" (76.2 mm to 1,194 mm) <br /> B - 155 OF (68 °C), 175 OF (79 °C), and 5- ENT'sprinkler with an ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 <br /> 200 OF (93 -C) mm to 1,156 mm) <br /> 6- ENT'with "A" dimensions 3-1/4" to 47-1/2" (82.5 mm to 1,207 mm) <br /> *Brass Finish is listed and approved but not standard offering,lead times of 6-8 weeks required. <br /> (Matching Brass escutcheons are not available.) <br /> Footnotes <br /> ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. <br /> 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). <br /> 3 Metric K-factor shown is for use when pressure is measured in bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. <br /> 4 This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.Check with the manufacturer <br /> for any additional approvals. <br /> 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada for Light Hazard occupancies only. <br /> 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E,Vol. 15. <br /> 'cULus Listed as corrosion resistant. <br /> DESIGN CRITERIA- UL <br /> (Also refer to Approval Chart 1 above.) <br /> cULus Listing Reguirements: <br /> Quick Response Dry Horizontal Sidewall Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edi- <br /> tion of NFPA 13 for standard spray sprinklers. <br /> • Limited to Light Hazard occupancies only. <br /> • Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. <br /> • Minimum spacing allowed is 6 ft. (1.8 m). <br /> • Deflector must be positioned between 4" and 6" (102 mm and 152 mm) below the ceiling. Keep the top of the deflector oriented parallel with <br /> the ceiling. <br /> • Locate no less than 4"(102 mm)from end walls. <br /> • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured <br /> perpendicular to the wall. <br /> • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. <br /> IMPORTANT.Always refer to Bulletin Form No. F_091699-Care and Handling of Sprinklers.Also refer to Form No. F_080614 <br /> for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest <br /> edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and <br /> also with the provisions of governmental codes, ordinances, and standards,whenever applicable. <br /> Form No. F_031993 20.04.16 Rev 20.1 <br />