Seismic Bracing <br /> TOLCO" Fig. 980 - Universal Swivel Sway Brace Attachment - 3/8" to 3/4" (FM Approved) <br /> OPM FM <br /> Size Range: One size fits bracing pipe 1" (25mm)thru 2"(50mm), B-Line series APPROVED <br /> 12 gauge(2.6mm) channel, and all structural steel up to 1/4"(31.7mm)thick. <br /> Material: Steel <br /> Function: Multi-functional attachment to structure or braced pipe fitting. <br /> Features: This product's design incorporates a concentric attachment <br /> opening which is critical to the performance of structural seismic connections. ® p <br /> NFPA 13 (2016)9.3.5.8.4 indicates clearly that fastener table load values are <br /> based only on concentric loading. Mounts to any surface angle. Break off bolt <br /> head assures verification of proper installation. A <br /> Installation: Fig.980 is the structural or transitional attachment component �i B <br /> of a longitudinal or lateral sway brace assembly. It is intended to be combined <br /> with the"bracing pipe"and TOLCO "braced pipe"attachment, Fig. 1000, 1001, Set Bolt <br /> 3000,4L, 4LA, or other TOLCO approved attachment to pipe to form a complete Included <br /> bracing assembly. NFPA 13 guidelines should be followed. Mounting Hardware <br /> Is Not Included <br /> To Install: Place the Fig. 980 onto the"bracing pipe".Tighten the set bolt until <br /> the head breaks off. Attachment can pivot for adjustment to proper brace angle. <br /> Approvals:—Approved by Factory Mutual Engineering(FM). Included in our <br /> Seismic Engineering Guidelines approved by the State of California Office of <br /> Statewide Health Planning and Development(OSHPD). For additional <br /> load, spacing and placement information relating to OSHPD projects, please l <br /> refer to our Seismic Engineering Guidelines, OPM-0052-13. <br /> For UL Listed information refer to UL Listed page 60. <br /> Note: Fig. 980 Swivel Attachment and Fig. 1000, 1001, 4L,4LA or other <br /> TOLCO approved attachment to pipe that make up a sway brace system of <br /> bracing materials which satisfies the requirements of Factory Mutual <br /> Fig.980 <br /> Engineering and the National Fire Protection Association (NFPA) o <br /> Finish: Plain, Electro-Ga Ivan ized or Stainless Steel. Fig.1001 <br /> Contact customer service for alternative finishes. <br /> Order By: Figure number and finish. I(/ Fig.980 <br /> Pat.#6,273,372,Pat.#6,517,030,Pat.#6,953,174, ; + Fig.4L <br /> ---- <br /> Pat.#6,708,930,Pat.#7,191,987,Pat.#7,441,730, Brace <br /> #'' <br /> Pat.#7,669,806 <br /> Designed to meet or exceed requirements of FM DS 2-8. Lateral Brace Longitudinal Brace <br /> Part Mtg.Hdw. Mounting Hole Max.Design Load"(FM) Approx. <br /> Number Size A B D 30'-44' 45'-59* 60'-74' 75'-90* Wt./100 <br /> in. (mm) in. Win) in. Win) in. (mm) lbs./(kN) lbs./(kN) lbs./(kN) lbs./(kN) lbs. (kg) <br /> 980-3/8 3/8" (9.5) 51/4-(133.3) 17/8- (47.6) 13/32"(10.3) 149 (67.6) <br /> 980-1/2* 1/2"(12.7) 51/4"(133.3) 17/8- (47.6) 17/32"(13.5) 1320 1970 2310 2550 148 (67.1) <br /> 980-5/8 5/8"(15.9) 51/4"(133.3) 17/8- (47.6) 11/16"(17.5) (5.87) (8.76) (10.27) (11.34) 147 (66.7) <br /> 980-3/4 3/4"(19.0) 51/4"(133.3) 17/8" (47.6) 13/16"(20.5) 146 (66.2) <br /> * Standard size. <br /> ** Installed with 1" or 11/4" Schedule 40 brace pipe. <br /> FM Approved design loads are based on ASD design method. <br /> Important! - For load information when using Fig. 980 with pre-installed or post-installed concrete anchors in <br /> compliance with NFPA 13 (2016) or ASCE 7-10, including prying factors,see load tables on pages AL-1 thru AL-21. <br /> Eaton's B-Line series seismic bracing components are designed to be compatible only with other B-Line series bracing components, <br /> resulting in a listed seismic bracing assembly. Eaton B-Line Division warranty for seismic bracing components will be the warranty <br /> provided in Eaton B-Line Division standard terms and conditions of sale made available by Eaton,except that, in addition to the other <br /> exclusions from Eaton B-Line Division warranty, Eaton makes no warranty relating to B-Line series seismic bracing components that are <br /> combined with products not provided by Eaton. <br /> All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. <br /> B-Line series Fire Protection Solutions 61 Eaton <br />