Data Sheet <br /> Cerberus PRO Fire Safety <br /> 50-Point Addressable Fire Alarm Control Panel <br /> Model FC901 <br /> ARCHITECT AND ENGINEER SPECIFICATIONS <br /> • An addressable fire alarm control panel(FACP) — — <br /> comprised of the following three(3)system <br /> components: sums <br /> d...r <br /> • Main board(Model FCM901-U3) <br /> • 170-Watt power supply(Model FP2011-U1) <br /> • System enclosure(Model FH901-U3/`.3) <br /> • System features: <br /> • Supports 50 addressable devices on one(1)'Class A', <br /> or one(1)—two(2)'Class B'circuits r <br /> • Includes one(1)'Class A',or two(2)'Class B' <br /> notification appliance circuits(NACs) <br /> • Built-in digital alarm communication transmitter <br /> (DACT) <br /> • Built-in RS-485 connection for remote annunciators <br /> • Resettable and non-resettable 24VDC auxiliary <br /> power • Alphanumeric keypad <br /> • Optional connectivity to a leased-line/city-tie • for manual configuration <br /> module . ®UL 864 9th Edition Listed; <br /> • Off-normal warning message prior to reset <br /> • Fast and easy set-up with custom-configuration tool FM, CSFM &NYC Fire Department Approved <br /> Product Overview Main Board <br /> Model FC901 is an addressable FACP that The Model FCM901-U3 main board provides system <br /> provides a cost-effective solution for simple fire- display and control, as well as connections for <br /> alarm system applications. system field wiring,via removable terminal blocks. <br /> Small and compact in design, Model FC901 is The 3.5-inch (8.9 centimeters) by 1.5"(3.8 <br /> ideal for small fire-protection applications using centimeters) liquid-crystal display(LCD)screen <br /> less than 50 addressable devices: shows all system messages and event status. Each <br /> • retail outlets/strip malls • doctors'offices event may have a custom message up to 28 <br /> • dry cleaner shops • restaurants,etc. characters that describes the event's location. <br /> With its built-in DACT and two(2) NACs, Model The backlit LCD screen illuminates on any system <br /> FC901 is powerful enough to economically event or manual key press. New,'unacknowledged' <br /> meet the needs of these applications. Each 50- events are indicated by a flashing exclamation point <br /> point FACP is FM,CSFM (Listing No.: 7165- ('I'). Once'acknowledged,'the exclamation point <br /> 0067:0259)and FDNY(Certificate of Approval: changes to a check mark('f'). A system-status line <br /> #6104)Approved. shows the quantity of events presently active. <br /> Specifications The main board supports system-status light- <br /> The Model FC901 FACP consists of a main board emitting diodes(LEDs), based upon the following <br /> (Model FCM901-U3);a 170-Watt power supply conditions of Model FC901: <br /> (Model FP2011-U1),and a Model FH901-U3 I • Power <br /> R3 system enclosure. The programming • Alarm <br /> y p g g Trouble <br /> software for Model FC901 is held in flash • Supervisory <br /> electrically erasable programmable read-only • Ground Fault <br /> memory (EEPROM). <br /> Cerbef uSTM PRO 9813 <br /> Fire Safety&Security Products FACP for simple-size buildings <br /> Answers for infrastructure SIEMENS <br /> �2q <br />