Laserfiche WebLink
Specifications— (continued) <br /> There are also LEDs to indicate when audible circuits Model FC901 can be configured using the <br /> are'active'or'silenced.' The main board supports four configuration tool or manually from the <br /> (4)system-control buttons, including: Acknowledge; alphanumeric keypad on the main board. An auto- <br /> Alarm Silence; Unsilence, and Reset. configuration feature creates a basic system <br /> The system offers an off-normal warning feature, configuration of all connected devices to accelerate <br /> alerting users when active devices are not ready for initial system commissioning. <br /> reset. These active devices may include manual <br /> stations that have not been reset;smoke detectors with 170-Watt Power Supply <br /> smoke remaining in the optical chamber,etc. The Model FCM901-U3 main board also supports <br /> Additionally,the main board supports an alphanumeric connection to the system power supply. The 170 <br /> keypad,as well as navigation keys,which are used for Watt power supply(Model FP2011 U1) incorporates <br /> scrolling maintenance functions and system a 4.OA, non-resettable slow blow fuse on the <br /> configuration. primary input, and includes a built-in AC-line filter <br /> for surge and noise suppression. Model FP2011-U1 <br /> The main board supports connection for up to 50 mounts in a standard Siemens—Fire Safety <br /> addressable devices,via one(1)'Class A',or one(1) to enclosure, and there are no serviceable Siemens— <br /> two(2)'Class B'circuits. The loop supports all C-NET Fire Safety parts to be maintained. <br /> devices, including the Cerberus PRO Fire Safety and <br /> Model'H'-series devices. The main board also supports <br /> one(1)'Class A'or two(2)'Class B'NACs. 50-Point Addressable System Enclosure <br /> Each NAC supports a maximum 2.5 Amps—with 2.5 The Model FH901-U3 / R3 enclosure for the 50-point <br /> Amps, max. allowed between the NACs. Each NAC addressable fire system, Model FC901, supports all <br /> can be set to a synchronized strobe,for horn-strobe system modules. The enclosure also supports 12AH <br /> devices, or for audible devices. Audible devices can batteries. <br /> be set for: Note: For systems requiring larger than 12AH batteries, <br /> ▪ STEADY' use a®UL Listed battery box. <br /> • 'ANSI Temporal 3' The Model FH901-U3 I R3 enclosure for the 50-point <br /> • 'March Time 30 1 60 1 120 Codes' panel is comprised of a dual-mounting setup that <br /> The main board supports four(4)'Form C'relays for allows the main board to be partially mounted in a <br /> Alarm, Trouble, Supervisory and user-programmable lower-to-upper position. When temporarily installed <br /> events. Each relay is rated at 2 Amps at 30VDC in the lower position,technicians are allowed more <br /> maximum, resistive. The main board supports two space to install field wiring at the time of system set- <br /> (2) auxiliary 24VDC connections. Upon system reset, up. When field-wiring installation is complete, the <br /> one (1) connection interrupts the power for five main board shall be moved to the upper position for <br /> seconds for use with (4) four-wire conventional standard mounting prior to applying power to the <br /> detectors. Each auxiliary-power output is 24VDC, system. <br /> nominal—rated at 0.75 Amps. Additionally, the enclosure supports an optional <br /> The main board contains a built-in DACT(Model battery bracket(Model FHA901-U1)that can be used <br /> FCA2015-A1),which provides communication between to secure batteries up to 12AH. Model FHA901-U1 is <br /> Model FC901 and with the central or remote required to comply with seismic certification, <br /> monitoring station. The built-in DACT supports two (2) pursuant to ASC I SEI 7-05, Section 13.2.2. <br /> separate programmable accounts,as well as two(2) A flush-mount trim kit(Model FHA902-U1 I R1) is <br /> connections to the public-switched telephone network. also available for use when flush mounting Model <br /> The connections support RJ31X male connectors. FH901-U3 I R3. <br /> The main board contains a battery-charging circuit, Optional Accessories <br /> providing connection to lead-acid batteries rated at The Model FC901 FACP has the capability of <br /> 24VDC, nominal. The main board can charge up to operating an optional leased-line, city-tie module <br /> 18 AH batteries. (Model FCI2020-U1)that provides a local-energy <br /> The main board contains a universal serial bus (USB) output for municipal call-box connection. The <br /> connector that supports connection for system leased-line, city-tie module is installed on the back of <br /> configuration and module firmware upload, via the the main board of the Model FC901 FACP, and all <br /> custom-configuration tool. field wiring is connected to the main board. <br /> SIEMENS Industry, Inc. Cerberusrm PRO <br /> Building Technologies Division <br /> 212A, <br />