My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3218 LOMBARD AVE 2025-07-14
>
Address Records
>
LOMBARD AVE
>
3218
>
3218 LOMBARD AVE 2025-07-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2025 9:05:44 AM
Creation date
1/29/2025 11:37:59 AM
Metadata
Fields
Template:
Address Document
Street Name
LOMBARD AVE
Street Number
3218
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
habitable spaces per this section. Please revise the plans to indicate that these are not <br /> habitable spaces. <br /> 8. 404.3. Bldg. 2, Basement Level and Unit 7 appear to not meet the T-0" minimum clear <br /> ceiling height. Where a pitched roof occurs in the bedrooms/sleeping area, please <br /> indicate how Exception 3 of 404.3 is satisfied. <br /> 9. 505.4. It appears that only one water heater is shown on the plans. Please indicate on <br /> the plans where water heater devices are shown on Bldg. 1 and Bldg. 3 and are <br /> sufficiently able to provide heated water. <br /> 10. 602.2. Heating in dwellings shall be provided capable of maintaining 680F in habitable <br /> rooms, bathrooms, and toilet rooms. Please indicate on plans or a narrative how each <br /> habitable room is achieving this requirement. <br /> 11. 605.2. Please indicate on the drawings locations of electrical receptacles. A minimum of <br /> (2) separate and remote receptacles are required for each habitable space. Laundry <br /> areas, a minimum of one grounding-type receptacle or with a ground fault circuit <br /> interrupter. Bathrooms shall not contain less than one receptacle with new bathroom <br /> receptacles having ground fault circuit interrupter protection. <br /> 12. 605.3. Please indicate on the plans the luminaries being provided for each public hall, <br /> interior stairway, toilet room, kitchen, bathroom, laundry room, boiler room, and furnace <br /> room in the buildings where the rooms occur. <br /> 13. 605.4. In some dwelling units, it appears that flexible cords for permanent wiring were <br /> used on site. Permanent wiring for electrical components should be installed in <br /> accordance with the NFPA 70 provisions. Additional permits would be required to <br /> complete work. <br /> 14. 704.2. Smoke alarms should be installed in the following locations and shown on the plans <br /> per 704.2.1.2, 704.2.1.3, and 704.2.1.4. Where smoke alarms are provided, alarms <br /> should receive primary power from the building with a battery back-up per 704.2.3. <br /> In order for the processing of your application to continue, it will be necessary to provide the <br /> Building Division with two new sets of revised construction documents reflecting the corrections <br /> requested. Please include a response letter which indicates how the corrections were resolved. <br /> All codes cited refer to the 2015 International Property Maintenance Code (IPMC), 2015 <br /> International Building Code (IBC), 2015 International Existing Building Code (IEBC), the 2015 <br /> International Fire Code (IFC), the 2015 International Mechanical Code (IMC), and/or the 2015 <br /> Washington State Energy Code (WSEC), as amended by the State of Washington and adopted <br /> by the City of Everett. The current IBC referenced standard for accessible design is the 2009 <br /> "Accessible and Usable Buildings and Facilities" (ICC/ANSI A117.1). Federal ADA regulations and <br /> standards may be more restrictive. <br /> 3002 Wetmore Ave. © 425.257.8800 everettpw@everettwa.gov <br /> Everett,WA 98201 425.257.8882 fax everettwa.gov <br />