220 OLYMPIC BLVD 2019 VERIZON ANTENNAS Plans 2025-03-27
>
Address Records
>
OLYMPIC BLVD
>
220
>
VERIZON ANTENNAS
>
Plans
>
220 OLYMPIC BLVD 2019 VERIZON ANTENNAS Plans 2025-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2025 9:24:37 AM
Creation date
1/29/2025 11:44:26 AM
Metadata
Fields
Template:
Address Document
Street Name
OLYMPIC BLVD
Street Number
220
Tenant Name
VERIZON ANTENNAS
Permit
B1905-007
Year
2019
Notes
INSTALL (6) ANTENNAS/ (1) MICROWAVE/ (6) TWIN DIPLEXERS (24)
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 00 NOT v'M F DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK <br /> SHOWN SHALL BE IMPLERENTED WRHOUT PRIOR RATTER <br /> APPROVAL ALL PREVIOUS ISSUES OF THIS DRAWING ARE <br /> O NOT USED SUPERSEDED BY THE LATEST REVISION.AT.DRAWINGS AND <br /> O NEW 24"x24" NEMA-3R ENCLOSURE (FIBER/SITE TECH CABINET) MOUNTED ON H—FRAME. ;1 SPECIFICATIONS REMAIN THE PROPERTY OF MORRISON <br /> HERSHFIELD CORPORATION.NETMER MORRISON HERSHFIELD <br /> NOR THE ARCHITECT WILL BE PROVIDING CONSTRUCTION <br /> REVIEW OF THIS PROJECT. <br /> O PROPOSED 2" PVC CONDUIT WITH (3) 1-1/4" INNERDUCTS AND TRACEABLE MULE TAPE ,FROM NEMA-3R TELCO ENCLOSURE TO FIBER CABINET. <br /> 0 NEW (2) $12 AWG CU. AND (1) $12 AWG CU. GROUND IN 1/2" RNC. <br /> ® PROPOSED FIBER HANDHOLE/PULLBOX. COORDINATE WITH FIBER PROVIDER FOR NEW - — _ •E 1 <br /> y CO <br /> SERVICE. - .,�.,.-�r� m ®. — e o —— — e m _ - f �iV.A, f <br /> O NOT USED. " Y/// / /v ,...1 <br /> �/ <br /> O7 NOT USED. " <br /> r Li <br /> ® NEW (3) $3/0 AWG CU. IN 3" RNC. I /////////////////////////////////////////./ I _ F"' _ i <br /> ® EXISTING UTILITY POLE MOUNTED TRANSFORMER. COORDINATE WITH UTILITY FOR NEW I <br /> 120/240V-10-3W, 200A FROM UTILITY POLE TO UTWTY POLE AND THEN UNDERGROUND 1 / / 1- <br /> SERVICE TO VERIZON WIRELESS MLItH. / / / / <br /> 9 / / ,F- 422.7 .,c) '• <br /> NEW (ILC) INTEGRATED LOAD CENTER. NEMA-3R PPC LOAD CENTER (PANEL "PP1") / ,I I / / + �.. <br /> 10 COMPLETE WITH AN INTEGRATED AUTOMATIC TRANSFER SWITCH, A 200A-2P UTILITY MAIN I / / I :.'.'t+ a', `�+ <br /> CIRCUIT BREAKER & A 200A-2P EMERGENCY MAIN CIRCUIT BREAKER. • •/ / 0 K�rSs'1pNA1. <br /> 11 GENERATOR PLUG. " / / I <br /> / <br /> 12 (3) 3/0 + (i) $6 GROUND, 2"C. PROVIDE RNC B.F.G. AND RGS A.F.G. ---/ / I - <br /> 13 NEW 2P-200A MAIN CIRCUIT BREAKER IN METER/MAIN CIRCUIT BREAKER COMBO WITH I <br /> INTERRUPTING CAPACITY=100K AIC. PROVIDE MECH.ATTACHED ENGRAVED LABEL INDICATING I % / I CONSTRUCTION <br /> "VERIZON WIRELESS METER". —� % I 0 <br /> 14 NEW 120/240V-18-3W, 200A RATED METER/MAIN CIRCUIT BREAKER COMBO MOUNTED AT — fTl I j <br /> NEW H-FRAME. PROVIDE MECH. ATTACHED ENGRAVED LABEL INDICATING 'VERIZON / / al <br /> WIRELESS ML!EN". - -- .- ,_.. / j <br /> NEW 200A CAPACITY 240V-10 NEMA 3R MEItN SOCKET PER POWER CO. REQUIREMENTS. I / ���/ <br /> 15 <br /> in / /// <br /> 16 PROPOSED (2) 4"PVC CONDUIT WITH (3) 1-1/4" INNERDUCTS AND TRACEABLE MULE —I I % % I 1 06/21/19 JURISDICTION COMMENTS <br /> TAPE FROM POINT OF FIBER CONNECTION TO NEMA-3R TELCO ENCLOSURE. INSTALL // I f / / <br /> CONDUITS IN A 36" BELOW GRADE TRENCH. COORDINATE EXACT REQUIREMENTS WITH FIBER <br /> PROVIDER. i j J 0 06/14/18 FINAL CONSTRUCTION <br /> O BOND TO GROUND RING W/$2 AWG SOLID TINNED COPPER. - I r J A 03/22/18 ISSUED FOR REVIEW <br /> 18 NEW MIN. $4 AWG CU TO (2) 5/8"X10' COPPER CLAD RODS SPACED A MINIMUM OF 6' I <br /> APART. VERIFY IN FIELD. I <br /> I / I No. Date Revision <br /> 19 NOT USED. _// Client: <br /> 20 NEW 2"CONDUIT FOR EQUIPMENT CABINET REFER TO LOAD CENTER DIAG. SHEET E-6 / ,' <br /> I / izo <br /> ONOT USED. vern <br /> NOT USED. ' - r. ////i///// / j�� <br /> O NEW H-FRAME FOR VERIZON EQUIPMENT. � I 1/////////////////////////////////////////li <br /> I <br /> 44 CONTRACTOR TO ARRANGE TO PAY FOR UNDERGROUND UTILITY LOCATION SURVEYS FOR Ala <br /> e® <br /> O ALL TRENCHING. REUSE NATIVE BACKFILL AND REINSTATE TO ORIGINAL CONDITION. INSTALL <br /> 6"WIDE METALLIC UNE RED PLASTIC MARKER TAPE 8"ABOVE ALL BURIED CONDUIT. I 0 <br /> ® F' UGP Implementation Team: <br /> 25 NOT USED. I """'- <br /> "� CROWN <br /> 28 NEW RADIO CABINET. I r... —— Ti -,15�1I�� r D l U� 0 <br /> 27 NEW PRIMARY POWER AND BATTERY ENCLOSURE. II I ;////////, ',, t ffi f �/• . / ON4/ CASTLE <br /> O. NEW H-FRAME LIGHT(LJTHONIA CAT$HFLI-LED-P1-40K-WFL-MVOLT OR EQUIVALENT). I 29 % / I j/ + 1505 WESTLAKE AVE N,SUITE eoO <br /> I / I !I SEATTLE,WA 98109 <br /> NEW 4 TO 6 HOUR CRANK TIME LIGHT SWITCH IN WEATHERPROOF ENCLOSURE. % / <br /> / I ////// 4 e�® 8® A&E Team: . <br /> I / 11'n <br /> I MORRISON HERSHFIELD <br /> I <br /> t______-- <br /> // <br /> I 600 STEWART ST,SUITE 200 <br /> SEATTLE,WA 98101 <br /> I Tel:206.268.7370 <br /> I <br /> _ www.morrisonhershfieid.crom <br /> I ProJaet Info: <br /> --- ®m / / BU# 825709 <br /> •• _.-_ . ' I MASONIC CENTER <br /> — 6 ""-` •=.� _...II,II <br /> 220 OLYMPIC BLVD. <br /> .:. EVERETT, WA 98203 <br /> Drawing Title: <br /> — — -------- W MUKILTEO BLVD ELECTRICAL <br /> SITE PLAN <br /> Project Number. Start Date: <br /> 1800386 03/22/18 <br /> Drafter. Designer. <br /> RR LB <br /> Project Manager. Professional of Record: <br /> NOTES: RKL RL <br /> 1.PROVIDE 17"x30" CONCRETE <br /> PULL-BOXES AT EVERY OTHER BEND Revision No: Sheet No: <br /> OR AS REQUIRED BY UTILITY COMPANY <br /> 0 E-2 <br /> ELECTRICAL REFERENCE NOTES 2 11"x1r� NOT <br /> SCALE <br /> SCALE ELECTRICAL SITE PLAN 1 <br />