Laserfiche WebLink
DO NOT SCALE DRAWINGS.CONTRACTOR MUST VERIFY ALL <br /> DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS OR <br /> ` APPROXIMATE LOCATION OF#2 AWG SOLID BARE TINNED GROUND RING. GROUND RING SHALL BE BURIED 30" OMISSIONS.NO VARIATIONS OR MODIFICATIONS TO WORK <br /> O BELOW THE FROST LINE OR 30" BELOW GRADE, WHICHEVER IS GREATER. EXACT LOCATION AND NUMBER OF SHOWN SHALL BE IMPLEMENTED WITHOUT PRIOR WRnTEN <br /> GROUND RODS TO BE DETERMINED ON SITE AND BASED ON 'FALL OF POTENTIAL GROUND RESISTANCE METHOD" APPROVAL.ALL PREVIGuS ISSUES OF THIS DRAWING ARE <br /> FOR RESISTANCE < 5 OHMS. UNLESS OTHERWISE NOTED, DRIVEN GROUND RODS ARE TO BE BURIED AT 16 FEET SUPERSEDEDP SY THE LATESTHPROPERTYREVISION.ALL DRAWINGSRISONMD <br /> INTERVALS. SPECIFICATIONS 5 RENNN THE RMORRISON MORRISON <br /> NOR THEET CORPARCHITECTORATION.WILL NEITHER INGC HICTI CONSTRUCTION <br /> NOR ISPROJECT.WILL BE PRONGING CONSTRUCTION <br /> ill RENEW OF THIS <br /> 2 PROVIDE 3/4"x10�-0" LONG COPPER CLAD STEEL(COPPER WELD) GROUND ROD AS SHOWN. PROVIDE INSPECTION <br /> O SLEEVE AT3 GROUND ROD TO SHOW BOND TO EXTERIOR BURIED GROUND RING (MINIMUM OF 4 INSPECTION <br /> SLEEVES/ SEE DETAIL 8/E-7). INSTALL GROUND ROD TWO (2) FEET MINIMUM AWAY FROM ANY SLAB. INSTALL SO <br /> THAT TOP OF GROUND ROD IS 30" BELOW GRADE OR FROST LINE, WHICHEVER IS DEEPER. EXACT LOCATION AND <br /> NUMBER OF GROUND RODS TO BE ESTABLISHED ON SITE AND BASED ON "FALL OF POTENTIAL GROUND 1 C E c <br /> RESISTANCE METHOD" FOR RESISTANCE < 5 OHMS. UNLESS OTHERWISE NOTED, DRIVIal GROUND RODS ARE <br /> BONDED TO THE BURIED GROUND RING AT 16 FEET INTERVALS. ' \ ,II INA.S/// 0 <br /> OEXISTING TOWER GROUND RING. VERIFY IN FIELD. L,.+. 9• "t_l. <br /> O #2 AWG STRANDED GREEN JACKET COPPER CONDUCTOR BONDING RRU TO ANTENNA GROUND BAR.O #2 AWG GROUND FROM SERVICE ENTRANCE GROUND ELECTRODE TO EXTERNAL GROUND RING <br /> O #2 AWG FROM H-FRAME TO EXTERNAL GROUND RING (TYP OF 2 PLACES). CHAIN LINK FENCE . 1 ' <br /> O7 #2 AWG GROUND FROM ICE BRIDGE VERTICAL POSTS TO Ex GROUND RING (Ti?). 7 r �r i �� <br /> ,• `i 'rr ,3'2 �k� w <br /> Og #2 AWG GROUND FROM VERTICAL FENCE POST TO EXTERNAL GROUND RING. ,.r,,4 f,�T f... M� <br /> 555+++//! r ,1 <br /> 90 NOT USED. } O `'$�fQNAL <br /> 10 NOT USED. 0 <br /> T/ — Y <br /> 11 EQUIPMENT GROUND RING AND TOWER GROUND RING SHALL BE BONDED TOGETHER IN AT LEAST TWO (2) POINTS © TYP �/'— —l—_�� <br /> USING A #2 AWG SOUD BARE TINNED COPPER CONDUCTOR. I 0 /- <br /> O12 BOND TO EQUIPMENT CABINET ENCLOSURE USING A MANUF. APPROVED CONNECTION WITH (2) # 2 AWG SOLID TYP I ��� GROUND ROD WITH CONSIl1UCT1ON <br /> BARE TINNED COPPER CONDUCTORS AND EXOTHERMICALLY WELD TO GROUND RING. -- - -----INSPECTION WELL <br /> O13 <br /> REFER TO STRUCTURAL AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ANTENNA(S) AND ANTENNA _ <br /> SUPPORTS FRAME. - <br /> OEXTEND GROUNDING CONDUCTOR TO ANTENNA LOCATIONS AND BOND TO ANTENNA PIPE MOUNT. USE AN I <br /> 14 EXOTHERMIC WELD AT ANTENNA PIPE MOUNT. SUPPORT CONDUCTOR AS REQUIRED EVERY TWO (2) FEET MINIMUM. _ <br /> PROVIDE #2 SOLID BARE TINNED COPPER CONDUCTOR FROM TEGB TO TOWER GROUND RING (TYP OF 2). j;,\;.. I 'I <br /> 15 I 1 06/21/19 JURISDICTION COMMENTS <br /> PROVIDE ANTENNA CABLE GROUND BAR. BOND ANTENNA CABLE GROUNDING KITS TO GROUND BAR. CONNECTION 12 <br /> SHALL BE THE RESPONSIBILITY OF THE ANTENNA CABLE INSTALLER. BOND GROUND BAR TO TOWER USING ONE (1) /'\ \ TYP I I <br /> 16 0 06/14/18 FINAL CONSTRUCTION <br /> #2 AWG SOLID TINNED COPPER CONDUCTOR. PROVIDE A U.L LISTED CONNECTOR SUITABLE FOR THE MATERIALS \ \, \. <br /> BONG CONNECIOu. PROVIDE EXOTHERMIC WELDS FOR BONDS TO STEEL BEAM OR FRAME. A 03/22/18 ISSUED FOR REVIEW <br /> O17 THE TOWER EXIT GROUND BUS BAR (TEGB) SHALL BE INSTALLED BELOW THE TRANSMISSION UNE GROUND KITS, \ V \ I — — — _II No. Date Revision <br /> NEAR THE AREA OF THE TOWER AT THE POINT WHERE THE ANTENNA TRANSMISSION UNES TRANSITION FROM THE \ I <br /> IL TOWER TO THE CABINETS.VERIFY EXACT LOCATION OF GROUNDING BAR FOR PROPER CONDUCTOR LENGTH. I -- - I Client: <br /> GROUNDING BAR PROVIDED BY THE ANTENNA CABLE INSTALLER. FINAL EXOTHERMIC WELD FROM THE BURIED n <br /> GROUNDING RING TO GROUND BAR SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. COORDINATE I r <br /> WITH ANTENNA CABLE INSTALLER FOR SCHEDULE TO MAKE CONNECTION. PROVIDE 3/4" PVC SLEEVE WITH SWEEP WA BRDIGE /� I i <br /> BEND IN NEW ANTENNA BASE INSTALLATIONS FOR CONNECTION OF TEGB TO TOWER GROUND RING. \� / . / -- I I ��� - verizon <br /> yam-- T --� <br /> O18 EXTEND GROUNDING CONDUCTORS TO REMAINING SECTOR ANTENNA PIPE MOUNT LOCATIONS AND BOND WITH 7 I I -- <br /> EXOTHERMIC WELDS TO ANTENNA PIPE MOUNT. SUPPORT CONDUCTOR AS REQUIRED EVERY TWO FEET MINIMUM. \ I \� I L —I <br /> 6 <br /> O. THE TOWER STRUCTURE SIttL SHALL BE UTILIZED FOR DISSIPATING THE LIGHTNING ENERGY. THE TOWER GROUND iffrii <br /> - <br /> I I - <br /> 7 BARS FOR ANTENNA GROUNDING SHALL BE DIRECTLY FASTENED TO THE STEEL STRUCTURE WITH STAINLESS STEEL <br /> HARDWARE&/OR ANGLE ADAPTORS (E.G. PIROD/VALMONT PART#167105 OR EQUIV. - W/O "CHERRY' - Implementation Team: <br /> INSULATORS. THIS TYPE OF INSTALLATION SPECIFICALLY PRECLUDES THE USE OF INSULATORS BETWEEN THE TOWER -� <br /> STRUCTURE &THE GROUND BARS & DOES NOT ALLOW ANY DRIWNG OF WELDING TO THE TOWER. I I - I_-/ <br /> ---'1 <br /> ,.. <br /> TYP ' ' CROWN <br /> I .�,/CASTLE <br /> igif %' __—__ - 1505 WS TLALEAVAE N,SUITE 800 <br /> SEATTLE, 8 <br /> I <br /> Is 1 I <br /> I ID AdeE Team: <br /> m� <br /> IO <br /> I I , O TYPICAL GROUNDING PLAN FOR (3) VERIZON <br /> WIRELESS CABINETS, (1) H-FRAME AND (2) <br /> ANTENNA/SECTOR MOUNT, REFER TO MORRISON HERSHFIELD <br /> /-- ARCHITECTURAL PAGES FOR LAYOUT. 600 STEWART ST,SUITE 200 <br /> / SEATTLE,WA 98101 <br /> II) . e,/ ® Tel:206.268.7370 <br /> ! E■ www.morrisonhershfieid.com <br /> Mir <br /> m ,- <br /> ' Project Info: <br /> BU#825709 <br /> I <br /> m� MASONIC CENTER <br /> T T 220 OLYMPIC BLVD. <br /> I -,.,. <br /> CO _ `_ 0 EVERETT,WA 98203 <br /> Drawing Title: <br /> 0 <br /> GROUNDING PLAN <br /> AND NOTES <br /> Project Number. Start Date: <br /> _______ 1800386 03/22/18 <br /> Drafter: Designer. <br /> NOTE: <br /> NO SOILS RESISTIVITY TESTING WAS PROVIDED AT THE TIME OF THIS DESIGN. RR LB <br /> Project Manager. Professional of Record: <br /> • RKL RL <br /> Revision No: Sheet No: <br /> 0 E®4 <br /> 11 xx17'SCALE:A NO TO SCALESCALE GROUNDING NOTES 2 11 x17"� No To S GROUNDING PLAN 1 <br />