Laserfiche WebLink
SITE PHOTO CARRIER: <br /> 00� <br /> SITE NAME. EVERGREEN WAY Sprinth <br /> SITE NUMBER: S E 54XC 102 PLAN PREPARED FOR: <br /> SITE TYPE: UTILITY POLE <br /> SITE ADDRESS: 6515 MORGAN ROAD coastal 2431 HILLS,C&TON 926 <br /> business SUITEO61009 <br /> LAGUNALGGUNA RILLS.Cd 8263] <br /> group,inc. <br /> - EVERETT, WA 98203 <br /> Spri nt> COUNTY: S N O H O M I S H PLAN PREPARED BY: <br /> JURISDICTION: CITY OF EVERETT LETS <br /> w AMERICA <br /> m _ Er-Q1r-_._&Architects <br /> p 112 S.Kyrene Rd.,Suite 1,Chandler,AZ 85226 <br /> a 602-526-7272-AE@LETSinc.com--LETSinc.com <br /> PROJECT INFORMATION VICINITY MAP CODE COMPLIANCE INDEX OF DRAWINGS LETS PROD. <br /> #: Cl—DP-048 <br /> SITE INFORMATION CONSTRUCTION MANAGEMENT: <br /> N SITE NAME: EVERGREEN WAY ALL WORK AND MATERIALS SHALL BE PREFORMED AND INSTALLED IN SHEET DESCRIPTION REV DATE <br /> ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES <br /> LATITUDE: 47 56' 19.3632" N (47.938712') T-1 TITLE SHEET 0 11/15/22 <br /> w AS ADOPTED BY THE LOCATION GOVERNING AUTHORITIES. NOTHING IN <br /> LONGITUDE: 127 13' 26.6118" W(-122.224055) THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT GN-1 GENERAL NOTES 0 11/15/22 ��I <br /> GLACIER VIEV: CONFORMING TO THE LATEST EDITIONS OF THE FOLLOWING: GN-2 GENERAL NOTES 0 11/15/22 <br /> JURISDICTION: CITY OF EVERETT IX 1. 3 a A-1 OVERALL SITE PLAN 0 11/15/22 ar. ox". <br /> CONSTRUCTION TYPE: V < fl <br /> iX a BUILDING CODE: A-2 ENLARGED SITE PLAN 0 11/15/22 6025 SCOTT WAY <br /> iX OCCUPANCY: U, (UNMANNED COMMUNICATIONS FACILITY) g a COMMERCE,CA 90040 <br /> cZ5 ZONING: R-2 ' S [INTERNATIONAL BUILDING CODE (IBC), 2018 AS ADOPTED BY THE A-3 EXISTING & FINAL EAST TOWER ELEVATION 0 11/15/22 <br /> R PARCEL NUMBER: 00393400002400 W m LOCAL JURISDICTION] <br /> a A.D.A COMPLIANCE: UNMANNED WIRELESS K REVISIONS <br /> ~ TELECOMMUNICATIONS FACILITY Value Village <br /> g ELECTRICAL CODE: REV. DATE DESCRIPTION INITIALS <br /> A 11/12/22 907o ZD SAC <br /> PROPERTY OWNER [NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70 — 2015, 0 11/15/22 CONSTRUCTION SET LHN <br /> 3 NAME: SOUTH EVERETT LIONS CLUB NATIONAL ELECTRICAL CODE, AS ADOPTED BY THE LOCAL <br /> r PO BOX 1404 PINEHURST-BEVERLY JURISDICTION] <br /> MARYSVILLE, WA 98270 SITE PARK LIGHTNING PROTECTION CODE: <br /> PHONE: (206) 528-2625 [NFPA 780 — 2002, LIGHTNING PROTECTION CODE] <br /> F APPLICANT INFORMATION 400 SUBCONTRACTOR'S WORK SHALL COMPLY WITH THE LATEST EDITION NOT FOR CONSTRUCTION UNLESS <br /> APPLICANT/CARRIER: SPRINT 751n OF THE FOLLOWING STANDARDS. LABELED AS CONSTRUCTION SET <br /> N 15395 SE 30TH PLACE AMERICAN CONCRETE INSTITUTE (ACI) 318, BUILDING CODE DIRECTIONS <br /> 9 BELLEVUE, WA 98007 4REQUIREMENTS FOR STRUCTURAL CONCRETE J { <br /> AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC), MANUAL OF DEPART FROM:SEATTLE-TACOMA INTERNATIONAL AIRPORT, <br /> Gs " 17801 INTERNATIONAL BLVD,SEATTLE,WA 98158 ••• <br /> o ELECTRIC PROVIDER: N/A — STEEL CONSTRUCTION, ASD, FIFTEENTH EDITION _ <br /> w PHONE: - — NORTH 1. HEAD SOUTH ON PACIFIC HWY S/TUKWILA INTERNATIONAL BLVD <br /> ANSI/TIA 222—H, STRUCTURAL STANDARDS FOR ANTENNA �A-�, ��;• <br /> 2. TURN LEFT TO MERGE WITH WA-518 E TOWARD 1-5/1-405/RENTON r <br /> a SUPPORTING STRUCTURES AND ANTENNAS. 3. MERGE WITH 1-5 N VIA THE RAMP ON THE LEFT TO SEATTLE 1 <br /> SCOPE OF WORK 1n z: <br /> 4. MERGE WITH 1-5 N <br /> THIS IS NOT AN ALL INCLUSIVE LIST. CONTRACTOR SHALL USE SPECIFIED TIA 607, COMMERCIAL BUILDING GROUNDING AND BONDING 5. USE THE 2ND FROM THE RIGHT LANE TO TAKE EXIT 164A FOR DEARBORN 0'; <br /> F EQUIPMENT PART OR ENGINEER APPROVED EQUIVALENT. CONTRACTOR REQUIREMENTS FOR TELECOMMUNICATIONS ST TOWARD JAMES ST/MADISON ST. CONTINUE ONTO 7TH AVE r�2811 <br /> SHALL VERIFY ALL NEEDED EQUIPMENT TO PROVIDE A FUNCTIONAL SITE. 6 •••� <br /> THE PROJECT GENERALLY CONSISTS OF THE FOLLOWING: T(� Gj <br /> 7. TURN LEFT ONTO MADISON ST FS•'••.......••.••••••�� <br /> — 3 REMOVE SPRINT PANEL ANTENNAS INSTITUTE FOR ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE) 8. TURN RIGHT AT THE 1ST CROSS STREET ONTO 6TH AVE S�ONAL pp <br /> — 9 REMOVE SPRINT RRUS 81, GUIDE FOR MEASURING EARTH RESISTIVITY, GROUND 9. SHARP RIGHT To MERGE WITH -5 N / 1 �2 2 <br /> — 3 REMOVE SPRINT FILTERS IMPEDANCE, AND EARTH SURFACE POTENTIALS OF A GROUND 10. USE THE RIGHT 2 LANES TO TAKE EXIT 189 FOR WA-526 W TOWARD 1 HEREBY CERTIFY THESE PUWS WERE <br /> g — 3 REMOVE SPRINT STAND—OFF ARMS MUKILTEO PREPARED BY ME OR UNDER MY DIRECT <br /> PROJECT TEAM - 1 REMOVE SPRINT COLLAR MOUNT SYSTEM SUPBZVISION AND THAT I AM A DULY <br /> — 3 REMOVE SPRINT PIPE MOUNTS 11. CONTINUE ONTO WA-526 W LINDER A&E FIRM — 1 REMOVE SPRINT BBU CABINET IEEE 1100 (1999) RECOMMENDED PRACTICE FOR POWERING AND 12. USE THE RIGHT 2 LANES TO TAKE THE EVERGREEN WAY EXIT SrAAITE OF N3TMf0 ` OF <br /> NAME: LETS AMERICA INC. — 1 REMOVE SPRINT MMBS CABINET GROUNDING OF ELECTRONIC EQUIPMENT 13. TURN RIGHT ONTO EVERGREEN WAY <br /> ADDRESS: 112 S. KYRENE ROAD, SUITE 1 — 1 REMOVE SPRINT METER 14. TURN LEFT ONTO MADISON ST <br /> o CHANDLER, AZ 85226 <br /> — 1 REMOVE SPRINT ELECTRICAL EQUIPMENT IEEE C2 NATIONAL ELECTRIC SAFETY CODE, LATEST VERSION 15. TURN RIGHT ONTO MORGAN RD EVERGREEN WAY <br /> o — 1 REMOVE SPRINT PPC SE54XC102 <br /> o PHONE: (480) 961-9151 — 2 REMOVE SPRINT EQUIPMENT BOXES <br /> z EMAIL: INFOOLETSINC.COM <br /> O — 1 REMOVE SPRINT H—FRAME ARRIVE AT: 6515 MORGAN ROAD,EVERETT,WA 98203 6515 MORW ROAD <br /> CONSTRUCTION — MOVE SPRINT CONDUITS TELCORDIA GR-1275, GENERAL INSTALLATION REQUIREMENTS EVERETT, WA 98203 <br /> MANAGEMENT FIRM — REMOVE SPRINT VERTICAL CABLE LADDER SNOHOMISH <br /> NAME: ALEXANDER MARTINEZ — REMOVE SPRINT COAX ENTRY PORT <br /> z — REMOVE SPRINT UNDERGRUND VAULT ANSI T1.31 1, FOR TELECOM — DC POWER SYSTEMS — TELECOM, <br /> o ADDRESS: 6025 SCOTT WAY ENVIRONMENTAL PROTECTION <br /> U — REMOVE SPRINT CABLE TRAY <br /> I COMMERCE, CA 90040 — REMOVE SPRINT CABLES SHEET TITLE <br /> 0 PHONE: (626) 716-2916 — REMOVE SPRINT CABLE LADDER <br /> N EMAIL: ALEXOBMIONLINE.US FOR ANY CONFLICTS BETWEEN SECTIONS OF LISTED CODES AND <br /> N PROJECT DO NOT SCALE DRAWINGS STANDARDS REGARDING MATERIAL, METHODS OF CONSTRUCTION, OR <br /> z MANAGEMENT FIRM z NAME: COASTAL BUSINESS GROUP, INC. CONTRACTOR SHALL VERIFY ALL PLANS, EXISTING DIMENSIONS & OTHER REQUIREMENTS, THE MOST RESTRICTIVE REQUIREMENT SHALL TO OBTAIN LOCATION OF PARTICIPANTS TITLE SHEET <br /> GOVERN. WHERE THERE IS CONFLICT BETWEEN A GENERAL UNDERGROUND FACILITIES BEFORE <br /> CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE <br /> c ADDRESS: 24310 MOULTON PKWY, SUITE 0 #1009 REQUIREMENT AND A SPECIFIC REQUIREMENT, THE SPECIFIC YOU DIG IN WASHINGTON,CALL UTILITY <br /> z LAGUNA HILLS, CA 92637 ARCHITECT OR ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE REQUIREMENT SHALL GOVERN. NOTIFICATION CENTER <br /> a PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 8f-10� CONTACT: DAMIEN PICHARDO <br /> $ PHONE: (949) 336-1550 TOLL FREE:1-800-424-5555 OR <br /> o EMAIL: DPICHARDOOCOASTALBUSINESSGROUP.NET LEGAL DESCRIPTION www.callbeforeyoudig.org <br /> LANDLORD: WASHINGTON STATUTE SHEET NUMBER <br /> NAME: CITY OF EVERETT Know what's below. REQUIRES MIN OF 2 <br /> 2 ADDRESS: 2302 RUCKER AVE #4, BATSIDE N/A WORKING DAYS NOTICE T 1 <br /> z EVERETT, WA 98201 Call before you dig. BEFORE YOU EXCAVATE <br /> w <br />