CARRIER:
<br /> GENERAL CONSTRUCTION NOTES: 0
<br /> N
<br /> 1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL BUILDING 22.CONTRACTOR SHALL MINIMIZE DISTURBANCE TO (E) SITE DURING 16.MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, 13.ALL CRIMPED CONNECTIONS SHALL HAVE EMBOSSED MANUFACTURER'S S r i n t r
<br /> CODE, THE LATEST ADOPTED EDITION AND ALL OTHER APPLICABLE CODES AND CONSTRUCTION. EROSION CONTROL MEASURES, IF REQUIRED DURING SHALL BE NEW AND SHALL APPEAR ON THE UST OF U.L. APPROVED ITEMS AND DIEMARK VISIBLE AT THE CRIMP (RESULTING FROM USE OF PROPER p
<br /> ORDINANCES. CONSTRUCTION SHALL BE IN CONFORMANCE WITH JURISDICTIONAL OR STATE SHALL MEET OR EXCEED THE REQUIREMENTS OF THE NEC, NEMA AND IECE AND WEATHER-PROOFED WITH HEAT SHRINK.
<br /> AND LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL AND . CRIMPING DEVICES)
<br /> 2. CONTRACTOR SHALL CONSTRUCT SITE IN ACCORDANCE WITH THESE DRAWINGS COORDINATED WITH LOCAL REGULATORY AUTHORITIES. CONTRACTOR SHALL BE 17•CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OR MANUFACTURER'S CATALOG 14.ALL CONNECTION HARDWARE SHALL BE TYPE 3-16 STAINLESS (NOT PLAN PREPARED FOR:
<br /> AND LATEST SPRM CONSTRUCTION STANDARDS. THE SPECIFICATION IS THE RESPONSIBLE FOR MAINTENANCE OF ANY EROSION CONTROL MEASURES, INFORMATION OF ANY ALL EQUIPMENT AND ALL OTHER ELECTRICAL ITEMS FOR
<br /> RULING DOCUMENT AND ANY DISCREPANCIES BETWEEN THE SPECIFICATIONS AND RECORD-KEEPING, MONITORING, AND REPORTING TO THE OWNER AND APPROVAL BY THE Y/ASPRIUL CM PRIOR TO INSTALLATION. ATTRACTED TO MAGNETS).
<br /> THE CONSTRUCTION DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE REGULATORY AUTHORITIES.
<br /> ARCHITECT/ENGINEER OR SPW CM PRIOR TO THE COMMENCEMENT OF WORK. 23.ALL CONSTRUCTION WORK IS TO ADHERE TO APPLICANT'S INTEGRATED 18.ANY CUTTING OR PATCHING DEEMED NECESSARY FOR ELECTRICAL WORK IS THE TESTING AND EQUIPMENT TURN UP REQUIREMENTS•
<br /> 3. CONTRACTOR SHALL VISIT THE JOB SITE AND SHALL FAMILIARIZE THEMSELVES CONSTRUCTION STANDARDS UNLESS STATE OR LOCAL CODE IS MORE ELECTRICAL CONTRACTORS RESPONSIBILITY AND SHALL BE INCLUDED IN THE coastal 24310 MOULTON PKwY.
<br /> STRINGENT. COST FOR WORK AND PERFORMED TO THE SATISFACTIONS OF THE SPRM CIA business SUITE
<br /> WITH ALL CONDITIONS AFFECTING THE (N) WORK AND SHALL MAKE PROVISIONS UPON FINAL ACCEPTANCE. 1. RF CABLE, DATA CABLE, RADIO EQUIPMENT AND BACK HAUL EQUIPMENT LACUNA HI009 CA.9263]
<br /> TESTING WILL COMPLY WITH CURRENT INDUSTRY STANDARDS AND OR THOSE
<br /> FA TO THE COST THEREOF. CONTRACTOR SHALL O RESPONSIBLE FOR group,inc.
<br /> 24.THE INTENT OF THE PLANS AND SPECIFICATIONS IS TO PERFORM THE STANDARDS OF THE EQUIPMENT MANUFACTURER OR PROVIDED TO THE
<br /> FAMILIARIZING THEMSELVES WITH ALL CONTRACT DOCUMENTS, FIELD CONDITIONS 19.THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS WITH ONLY TYPEWRITTEN CONTRACTOR PRIOR TO TESTING.
<br /> CONSTRUCTION IN ACCORDANCE PER STATE BUILDING STANDARDS CODE AND
<br /> AND DIMENSIONS AND CONFIRMING THAT THE WORK AAN BE ACCOMPLISHED, AS DIRECTORIES. ALL ELECTRICAL WIRING SHALL BE THE RESPONSIBILITY OF THE
<br /> STATE CODE OF REGULATIONS. SHOULD ANY CONDITIONS DEVELOP NOT
<br /> SHOWN. PRIOR TO PROCEEDING WITH CONSTRUCTION.ANY DISCREPANCIES SHALL
<br /> BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER OR SPRRR CM COVERED BY THE APPROVED PLANS AND SPECIFICATIONS WHEREIN THE ELECTRICAL CONTRACTOR. 2. CONTRACTOR WILL USE THE APPROPRIATE CALIBRATED TESTING EQUIPMENT IN
<br /> FINISHED WORK WILL NOT COMPLY PER STATE CODE OF REGULATIONS,A THE TESTING OF RF CABLE, DATA CABLE, RADIO EQUIPMENT AND BACK HAUL
<br /> PRIOR O THE COMMENCEMENT OF WORK. NO COMPENSATION WILL BE AWARDED SCOPE OF WORK DETAILING AND SPECIFYING THE REQUIRED WORK SHALL BE 20.QUICK QUICK-MAKE
<br /> SWITCHES SHALL K NCLRATED, H.P. RATED HEAVY-DUTY, EQUIPMENT THAT MEET INDUSTRY STANDARDS OF THE MANUFACTURER OR PLAN PREPARED BY:
<br /> BASED ON CLAIM OF LACK OF KNOWLEDGE OF FIELD CONDITIONS. SUBMITTED TO AND APPROVED BY THE JURISDICTION BEFORE PROCEEDING TYPQUICK-MAKE AND QUICK-BREAK ENCLOSURES, AS REQUIRED BY EXPOSURE THOSE STANDARDS PROVIDED TO THE CONTRACTOR PRIOR TO TESTING.
<br /> 4. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF WITH THE WORK. A CHANGE ORDER FOR THAT SCOPE SHALL BE SUBMITTED
<br /> E' ��
<br /> CONSTRUCTION. CONTRACTOR IS REQUIRED TO FURNISH AND INSTALL ANY/ALL TO THE SPRM CM PRIOR TO PROCEEDING WITH THE WORK. 21.ALL CONNECTIONS SHALL BE MADE WITH A PROTECTIVE COATING OF AN 3. CONTRACTOR TO VERIFY AND RECORD ALL TEST RESULTS AND PROVIDE
<br /> ITEMS FOR A COMPLETE AND FULLY FUNCTIONAL SYSTEM SUBJECT ONLY TO 25.ADEQUATE AND REQUIRED LIABILITY INSURANCE SHALL BE PROVIDED BY THE ANTI-OXIDE COMPOUND KNOWN AS "NO-OXIDE A" 8Y DEARBONE CHEMICAL CO. THESE RESULTS WITHIN THE FINAL CLOSE OUT PACKAGE.
<br /> d OWNER-SUPPLIED ITEMS. CONTRACTOR SHALL PROVIDE ANY/ALL REQUIREMENTS CONTRACTOR FOR PROTECTION AGAINST PUBLIC LOSS AND ANY/ALL COAT ALL WIRE SURFACES BEFORE CONNECTING. EXPOSED COPPER SURFACES, 4. ALL PERSONNEL INVOLVED IN THE TESTING OF RF CABLE, DATA CABLE, RADIO AMERICA
<br /> w FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING ORDER. INCLUDING GROUND BARS, SHALL BE TREATED - NO SUBSTITUTIONS.
<br /> m PROPERTY DAMAGE FOR THE DURATION OF WORK. EQUIPMENT AND BACK HAUL EQUIPMENT WILL BE REQUIRED TO HAVE BEEN
<br /> = 22.RACEWAYS: CONDUIT SHALL BE SCHEDULE 80 PVC MEETING OR EXCEEDING TRAINED AND OR CERTIFIED IN THE PROPER TESTING OF RF CABLE, DATAEd-K `�&'A'rchlMects
<br /> 0 5. PLANS ARE NOT TO BE SCALED. THESE PLANS ARE INTENDED TO BE A 26.CONTRACTOR SHALL GUARANTEE ANY/ALL MATERIALS AND WORK FREE FROM CABLE, RADIO EQUIPMENT AND BACK HAUL EQUIPMENT. 112 S.Kyrene Rd.,Suite 1,Chandler,AZ 85226
<br /> G_ DIAGRAMMATIC OUTLINE ONLY UNLESS OTHERWISE NOTED. THE WORK SHALL NEMA TC2 - 1990. CONTRACTOR SHALL PLUG AND CAP EACH END OF SPARE
<br /> o_ INCLUDE FURNISHING MATERIALS, EQUIPMENT AND APPURTENANCES, AND LABOR DEFECTS FOR A PERIOD CT NOT LESS THAN ONE YEAR FROM DATE OF 602-526-7272-AE@LETSinc.com-w LETSinc.com
<br /> AND EMPTY CONDUITS AND PROVIDE TWO SEPARATE PULL STRINGS - 200 Ibs
<br /> � NECESSARY TO EFFECT ALL INSTALLATIONS AS INDICATED ON THE DRAWINGS. ACCEPTANCE.ANY CORRECTIVE WORK SHALL BE COMPLETED AT THE SOLE 5. ALL TEST RESULTS SHALL BE TIME STAMPED, RECORDED AND PRESENTED LETS PROJ. CI-DP-048
<br /> r TEST POLYETHYLENE CORD.ALL CONDUIT BENDS SHALL MEET WITH
<br /> FOR PRIOR TO ENERGIZING AND TURN UP OF ANY EQUIPMENT.
<br /> OWNER PROVIDED AND CONTRACTOR INSTALLED MATERIALS WILL INCLUDE THE ELECTRICAL NOTES GALVANIZED STEEL.ALL FIl'TINGS SHALL BE SUITABLE FOR USE WITH THREADED
<br /> FOLLOWING, UNLESS NOTED OTHERWISE: RIGID CONDUIT. COAT ALL THREADS WITH 'BRITE ZINC' OR 'COLD GAILY. CONSTRUCTION MANAGEMENT:
<br /> rn LL 1. ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL ANY/A ELECTRICAL 6. GPS EQUIPMENT (WHEN REQUIRED) IS NOT L DAMAGE THE GPS UNIT.
<br /> 0BE TESTED OR ATTACHED TO
<br /> A.TRANSMITTER INDICATED. ANY/ALL CONSTRUCTION SHALL BE IN ACCORDANCE W/ 23.SUPPORT OF ALL ELECTRICAL WORK SHALL BE AS REQUIRED BY NEC. ANY CABLING DURING TESTING, DOING SO WILL
<br /> B. UHF ANTENNA AND MOUNTING BRACKETS, GPS ANTENNA AND KU ANTENNAS WORK
<br /> u1 DRAWINGS AND ANY/ALL APPLICABLE SPECIFICATIONS. IF ANY PROBLEMS ARE 7. PRIOR TO TESTING IF THE CONTRACTOR HAS ANY QUESTIONS ABOUT THE
<br /> w C. UHF COAX AND HANGERS 24.CONDUCTORS: CONTRACTOR SHALL USE 98% CONDUCTIVITY COPPER WITH TYPE
<br /> � D. INTEGRATED LOAD CENTER ENCOUNTERED BY COMPLYING WITH THESE REQUIREMENTS, CONTRACTOR SHALL THWN INSULATION, UNLESS OTHERWISE NOTED, 600 VOLT, COLOR CODED. USE TESTING PROCEDURES THEY ARE TO CALL AND OBTAIN ASSISTANCE FROM A
<br /> NOTIFY~CM AS SOON AS POSSIBLE,AFTER THE DISCOVERY OF THE STRANDED COPPER FOR WIRE UP TO AND INCLUDING NO. 8 AWG. USE QUALIFIED DESIGNATED TESTING REPRESENTATIVE. ��I
<br /> w
<br /> v! 6. DIMENSIONS SHOWN ARE TO FINISH SURFACES UNLESS OTHERWISE NOTED. PROBLEMS. AND SHALL NOT PROCEED WITH THAT PORTION OF WORK, UNTIL
<br /> THE SPli CM HAS DIRECTED THE CORRECTIVE ACTIONS TO BE TAKEN. STRANDED CONDUCTORS FOR WIRE ABOVE MO. 8 AWG. 8. EQUIPMENT IS NOT TO BE ENERGIZED UNTIL ALL TESTING HAS BEEN
<br /> SPACING BETWEEN EQUIPMENT IS REQUIRED CLEARANCE. THEREFORE, IT IS COMPLETED,APPROVED AND THE APPROPRIATE AUTHORITY HAS BEEN
<br /> W CRITICAL TO FIELD VERIFY DIMENSIONS. SHOULD THERE BE ANY QUESTIONS 25.CONNECTORS FOR POWER CONDUCTORS: CONTRACTOR SHALL USE SPLICE KITS
<br /> o: 2. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE AND FAMILIARIZE NOTIFIED AND GIVES APPROVAL TO ENERGIZE THE EQUIPMENT.
<br /> REGARDING THE CONTRACT DOCUMENTS, (E) CONDITIONS AND/OR DESIGN INTENT, CLEAR EPDXY SPLICE KITS FOR N0. 10 AWG AND SMALLER. USE ESS 6025 SCOTT WAY
<br /> THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPORTING ANY DISCREPANCIES THEMSELVES WITH ANY/ALL CONDITIONS AFFECTING ELECTRICAL AND MECHANICAL TERMINAL LUGS FOR N0. 8 AWG AND LARGER. COR #8 SPLICES COMMERCE,GA 90040
<br /> TO THE ATTENTION OF THE SPRKT CM, IN WRITING, PRIOR TO THE COMMUNICATION INSTALLATION AND MAKE PROVISIONS AS TO THE COST SHOULD ISE IRREVERSIBLE CRIMPS AND 3M SCOTCHCAST 82A1/8281 EPDXY SITE WORK NOTES:
<br /> COMMENCEMENT OF WORK. THEREOF. ALL(E) CONDITIONS OF ELECTRICAL EQUIP., ETC.,THAT ARE PART OF KITS.
<br /> m THE FINAL SYSTEM, SHALL BE VERIFIED BY THE CONTRACTOR, PRIOR TO THE 7. DETAILS PROVIDED ARE FOR THE PURPOSE OF SHOWING DESIGN INTENT. REVISIONS
<br /> w SUBMITTING OF THEIR BID. FAILURE TO COMPLY WITH THIS PARAGRAPH WILL IN 1. DO NOT EXCAVATE OR DISTURB BEYOND THE PROPERTY LINES OR LEASE
<br /> r 2fi.SERVICE: AS SPECIFIED ON THE DRAWINGS. OWNER OR OWNER'S AGENT WILL
<br /> S MODIflCATI0N5 MAY BE REQUIRED TO SUIT JOB DIMENSIONS OR SITE NO WAY RELIEVE CONTRACTOR OF PERFORMING ALL WORK NECESSARY FORA APPLY FOR POWER.ALL PROVISIONS FOR TEMPORARY POWER WILL BE OBTAINED LINES, UNLESS OTHERWISE NOTED. REV, DATE DESCRIPTION INRWS
<br /> CONDITIONS, AND SUCH MODIFICATIONS SHALL BE INCLUDED AS PART OF THE COMPLETE AND WORKING SYSTEM. BY THE CONTRACTOR. A 11 12 22 90%ZD SAC
<br /> WORK. 2. SIZE, LOCATION AND TYPE OF ANY UNDERGROUND UTILITIES OR
<br /> 3. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITION OF 27.TELEPHONE OR FIBER SERVICE: CONTRACTOR SHALL PROVIDE EMPTY CONDUITS IMPROVEMENTS SHALL BE ACCURATELY NOTED AND PLACED ON AS-BUILT 0 11 15 22 CONSTRUCTION SET LHN
<br /> = 8. CONTRACTOR SHALL PAY FOR APPLICABLE PERMITS, FEES, INSPECTIONS AND THE NEC,ALL CODES AND ORDINANCES OF THE LOCAL JURISDICTION, AND WITH PULL STRINGS AS INDICATED ON DRAWINGS. DRAWINGS BY GENERAL CONTRACTOR AND ISSUED TO ARCHITECT/ENGINEER
<br /> 3 TESTING. CONTRACTOR IS TO OBTAIN PERMITS AND APPROVED SUBMITTALS PRIOR POWER &TELEPHONE COMPANIES HAVING JURISDICTION AND SHALL INCLUDE AT COMPLETION OF PROJECT.
<br /> TO ORDERING MATERIALS AND THE COMMENCEMENT OF WORK. BUT ARE NOT BE LIMITED TO: 28.ELECTRICAL AND TELCO/FIBER RACEWAYS TO BE BURIED A MINIMUM DEPTH OF
<br /> 30" UNLESS OTHERWISE NOTED 3. ALL(E) UTILITIES, FACILITIES, CONDITIONS AND THEIR DIMENSIONS SHOWN ON
<br /> 9 THE TERM 'PROVIDE" USED IN CONSTRUCTION DOCUMENTS AND SPECIFICATIONS, A , .UL - UNDERWRITERS LABORATORIES PLANS HAVE BEEN PLOTTED FROM AVAILABLE RECORDS.THE ENGINEER AND
<br /> .
<br /> z A. NEC - NATIONAL ELECTRICAL CODE OWNER ASSUME NO RESPONSIBILITY WHATSOEVER AS TO THE SUFFICIENCY OR
<br /> F INDICATES THAT THE CONTRACTOR SHALL FURNISH AND INSTALL. B. NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOC. 29.CONTRACTOR SHALL PLACE 6"WIDE DETECTABLE WARNING TAPE AT A DEPTH OF ACCURACY OF THE INFORMATION SHOWN ON THE PLANS OR THE MANNER OF
<br /> s 10.CONTRACTOR SHALL RECEIVE CLARIFICATION IN WRITING, AND SHALL RECEIVE IN C. OSHA - OCCUPATIONAL SAFETY AND HEALTH ACT 6" BELOW GROUND AND DIRECTLY ABOVE ELECTRICAL AND TELCO SERVICE THEIR REMOVAL OR ADJUSTMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR
<br /> = WRITING D. SBC - STANDARD BUILDING CODE CONDUITS. CAUTIONS TAPE TO READ "CAUTION BURIED ELECTRIC" OR "BURIED DETERMINING EXACT LOCATION OF ALL (E) UTILITIES AND FACILITIES PRIOR TO NOT FOR CONSTRUCTION UNLESS
<br /> r E. NFPA - NATIONAL FIRE PROTECTION AGENCY TELECOM". START OF CONSTRUCTION. CONTRACTOR SHALL ALSO OBTAIN FROM EACH
<br /> F. ANSI -AMERICAN NATIONAL STANDARDS INSTITUTE UTILITY COMPANY DETAILED INFORMATION RELATIVE TO WORKING SCHEDULES LABELED AS CONSTRUCTION SET
<br /> 11.CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING ACCEPTED G. IEEE - INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 30.ALL BOLTS, NUTS, WASHERS & LOCK WASHERS SHALL BE 3-16 STAINLESS AND METHODS OF REMOVING OR ADJUSTING E UTILITIES.
<br /> INDUSTRY-STANDARD SKILLS AND ATTENTION. CONTRACTOR SHALL BE SOLELY ()
<br /> N H. ASTM - AMERICAN SOCIETY FOR TESTING MATERIALS STEEL. _
<br /> RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS,TECHNIQUES, SEQUENCES
<br /> o AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER GROUNDING NOTES: 4. CONTRACTOR SHALL VERIFY ALL (E) UTILITIES BOTH HORIZONTALLY AND
<br /> CONTRACT, UNLESS OTHERWISE NOTED. 4. REFER TO SITE PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL VERTICALLY PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES OR
<br /> rn EQUIPMENT,AND CONFIRM WITH SPRNR CM ANY SIZES AND LOCATIONS WHEN
<br /> � NEEDED. 1. ALL HARDWARE SHALL BE 3-16 STAINLESS STEEL, INCLUDING LOCK DOUBTS AS TO THE INTERPRETATION OF PLANS SHALL BE IMMEDIATELY
<br /> 12.CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE WORK AREA, WASHERS. COAT ALL SURFACES WITH AN ANTI-OXIDANT COMPOUND,AS REPORTED TO THE ARCHITECT/ENGINEER OR SPAMQ CM FOR RESOLUTION
<br /> o ADJACENT AREAS AND BUILDING OCCUPANTS THAT ARE LIKELY TO BE AFFECTED SPECIFIED, BEFORE MATING.ALL HARDWARE SHALL BE STAINLESS STEEL 3/8 AND INSTRUCTION,AND NO FURTHER WORK SHALL BE PERFORMED UNTIL -
<br /> 5. (E) SERVICES: CONTRACTOR SHALL NOT INTERRUPT(E) SERVICES WITHOUT INCH DIAMETER OR LARGER. AS
<br /> w BY THE WORK UNDER THIS CONTRACT. WORK SHALL CONFORM TO ALL OSHA THE DISCREPANCY IS CHECKED AND CORRECTED BY THE ��..
<br /> REQUIREMENTS. WRITTEN PERMISSION OF THE OWNER. ARCHITECT/ENGINEER. FAILURE TO SECURE SUCH INSTRUCTION MEANS 1A,t=
<br /> } Q
<br /> a 13.CONTRACTOR SHALL COORDINATE THEIR WORK WITH THE SPRM CM AND 2. FOR GROUND BOND TO STEEL ONLY: INSERT A CADIUM FLAT WAHSER CONTRACTOR WILL HAVE WORKED AT THEIR OWN RISK AND EXPENSE. z 6. CONTRACTOR SHALL CONFIRM WITH LOCAL UTILITY COMPANY ANY/ALL BETWEEN LUG AND STEEL, COAT ALL SURFACES WITH AN ANTI-OXIDANT CONTRACTOR SHALL CALL LOCAL UTILITY LOCATE HOT LINE, SUCH AS 811, F"
<br /> SCHEDULE THEIR ACTIVITIES AND WORKING HOURS IN ACCORDANCE WITH THE REQUIREMENTS SUCH AS THE: LUG SIZE RESTRICTIONS, CONDUIT ENTRY, SIZE COMPOUND BEFORE MATING. FOR UTILITY LOCATIONS A MINIMUM OF 48 HOURS PRIOR TO START OFuj V1 'C
<br /> REQUIREMENTS. OF TRANSFORMERS, SCHEDULED DOWNTIME FOR THE OWNERS' CONFIRMATION, CONSTRUCTION.
<br /> ETC... ANY/ALL CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE 3. ALL STEEL CONDUIT SHALL BE BONDED AT BOTH ENDS WITH GROUNDING "
<br /> 14.CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE SPRINT CM, PRIOR TO BEGINNING ANY WORK. •Q 52811 Qt�
<br /> � BUSHING. 5. ALL NEW AND (E) UTILITY STRUCTURES ON SITE AND IN AREAS TO BE �+'.
<br /> WORK OF OTHERS AS IT MAY RELATE TO RADIO EQUIPMENT, ANTENNAS AND ANY
<br /> DISTURBED BY CONSTRUCTION SHALL BE ADJUSTED TO FINISH ELEVATIONS
<br /> OTHER PORTIONS OF THE WORK. 7. MINIMUM WIRE SIZE SHALL BE#12 AWG, NOT INCLUDING CONTROL WIRING, 4. ALL ELECTRICAL AND GROUNDING AT THE TOWER SITE SHALL COMPLY WITH PRIOR TO FINAL INSPECTION OF WORK. ANY COST RELATED TO ADJUSTINGGIS"['E�
<br /> UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE COPPER WITH THWN THE NATIONAL ELECTRICAL CODE (NEC), NATIONAL FIRE PROTECTION (E) STRUCTURES SHALL BE BORNE SOLELY BY THE CONTRACTOR. �S '•••...... U'
<br /> 15.CONTRACTOR SHALL INSTALL ALL EQUIPMENT AND MATERIALS N ACCORDANCE INSULATION, UNLESS OTHERWISE NOTED. ASSOCIATION (NFPA) 780 (LATEST EDITION, AND MANUFACTURER. SI
<br /> WITH MANUFACTURERS RECOMMENDATIONS UNLESS SPECIFICALLY OTHERWISE ANAL �1
<br /> INDICATED OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE. 8. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH 6. GRADING OF THE SITE WORK AREA IS TO BE SMOOTH AND CONTINUOUS IN / I 0 2
<br /> 5. ALL DETAILS ARE SHOWN IN GENERAL TERMS ACTUAL GROUNDING SLOPE AND IS TO FEATHER INTO (E) GRADES AT THE GRADING LIMITS.
<br /> a THREADED HUBS IN WET/DAMP LOCATIONS AND SPECIAL ENCLOSURES FOR INSTALLATION AND CONTRUCTION MAY VARY DUE TO SITE SPECIFIC KI HEREBY CERTIFY THESE PLANS WERE
<br /> 16.CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT (E) OTHER CLASSIFIED AREAS. CONDITIONS. 7. ALL TEMPORARY EXCAVATIONS FOR THE INSTALLATION OF FOUNDATIONS, PREPARED BY ME OR UNDER MY DIRECT
<br /> a SURFACES, EQUIPMENT, IMPROVEMENT, PIPING ETC. AND IMMEDIATE REPAIR,TO UTILITIES, ETC., SHALL BE PROPERLY LAID BACK OR BRACED IN ACCORDANCE SUPERVISION AND TWIT I AM A DULY
<br /> N NEW CONDITION,ANY DAMAGE THAT OCCURS DURING CONSTRUCTION AT THE 9. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF THE 6. GROUND ALL ANTENNA BASES, FRAMES, CABLE RUNS, AND OTHER METALLIC WITH CORRECT OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) REGISTERED ENGINEER UNDER THE LAWS OF THE
<br /> SOLE COST OF THE CONTRACTOR. CONSTRUCTION. CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS COMPONENTS USING /6 GROUND WIRES. FOLLOW ANTENNA AND BTS REQUIREMENTS. STATE OF WASHINGTON"
<br /> FOR A COMPLETE ELECTRICAL ELECTRICAL SYSTEM AND PROVIDE ALL MANUFACTURER'S PRACTICES FOR GROUNDING REQUIREMENTS.
<br /> z 17.IN DRILLING HOLES, OR CORING, INTO CONCRETE WHETHER FOR FASTENING OR REQUIREMENTS FOR THE EQUIPMENT TO BE PLACED IN PROPER WORKING
<br /> ANCHORING PURPOSES, OR PENETRATIONS THROUGH THE FLOOR FOR CONDUIT ORDER. 8. STRUCTURAL FILLS SUPPORTING PAVEMENTS SHALL BE COMPACTED TO 95%
<br /> RUNS, PIPE RUNS, ETC., MUST BE CLEARLY UNDERSTOOD THAT REINFORCING 7. ALL GROUND CONNECTIONS SHALL BE6 AWG, UNLESS OTHERWISE NOTED. OF MAXIMUM STANDARD PROCTOR DRY DENSITY, UNLESS OTHERWISE NOTED.
<br /> p STEEL SHALL NOT BE DRILLED INTO, CUT OR DAMAGED UNDER ANY 10.ELECTRICAL SYSTEM SHALL BE AS COMPLETELY AND EFFECTIVELY GROUNDED, ALL WIRES SHALL BE COPPER WITH THWN, UNLESS OTHERWISE NOTED. ALL EVERGREEN WAY
<br /> o GROUND WIRE SHALL BE SOLID TIN COATED OR STRANDED GREEN INSULATED 9. NEW GRADES NOT IN BUILDING AND DRIVEWAY IMPROVEMENT AREA TO BE
<br /> CIRCUMSTANCES (UNLESS NOTED OTHERWISE). LOCATIONS OF REINFORCING STEEL AS REQUIRED BY SPECIFICATIONS, SET FORTH 81'APPLICANT.
<br /> z ACHIEVED BY FILLING WITH APPROVED CLEAN FILL AND COMPACTED TO 95% SE54XC102
<br /> p ARE NOT DEFINITELY KNOWN AND THEREFORE MUST BE LOCATED BY THE WIRE. OF STANDARD PROCTOR DENSITY. 6515 MORGAN ROAD
<br /> r CONTRACTOR USING APPROPRIATE METHODS AND EQUIPMENT PRIOR TO ANY 11.ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN
<br /> c1 DRILLING CORING OPERATIONS IN (E) CONCRETE. A FIRST CLASS, WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL CONTRACTOR TO VERIFY AND TEST GROUND TO SOURCE, 10 OHMS MAXIMUM. EVERETT, WA 98203
<br /> FULLY FUNCTIONAL AND SHALL BE APPROVED BY THE SPRINT CM PRIOR AND
<br /> 8.
<br /> D PROVIDE SUPPLEMENT GROUNDING RODS AS REQUIRED TO ACHIEVE SPECIFIED 10.ALL FILL SHALL BE PLACED IN UNIFORM LIFTS. THE LIFTS THICKNESS
<br /> OHMS READING. GROUND AND OTHER OPTIONAL TESTING WILL BE WITNESSED SHOULD NOT EXCEED THAT WHICH CAN BE PROPERLY COMPACTED SNOHOMISH
<br /> 18.CONTRACTOR SHALL REPAIR,TO NEW CONDITION,ALL(E) WALL SURFACES LOCAL JURISDICTION.ANY DEFICIENCIES SHALL BE CORRECTED BY AN BY THE SPRINT CM. THROUGHOUT IT'S ENTIRE DEPTH WITH THE EQUIPMENT AVAILABLE.
<br /> 0 DAMAGED DURING CONSTRUCTION SUCH THAT THEY MATCH AND BLEND IN WITH ELECTRICAL CONTRACTOR AT THE SOLE COST OF THE CONTRACTOR.
<br /> o ADJACENT SURFACES. 9. NOTIFY ARCHITECT/ENGINEER IF THERE ARE ANY DIFFICULTIES INSTALLING 11.ANY FILLS PLACED ON (E) SLOPES THAT ARE STEEPER THAN 10 HORIZONTAL
<br /> 12.ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID SHEET TITLE
<br /> 19.CONTRACTOR SHALL SEAL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES OR INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. GROUNDING SYSTEM DUE TO SITE SOIL CONDITIONS. TO 1 VERTICAL SHALL BE PROPERLY BENCHED INTO THE (E) SLOPE AS
<br /> t+ MATERIALS WITH U.L. LISTED AND FIRE CODE APPROVED MATERIALS AND SYSTEMS DIRECTED BY A GEOTECHNICAL ENGINEER.
<br /> rn 10.ALL HORIZONTALLY RUN GROUNDING CONDUCTORS SHALL BE INSTALLED A
<br /> THAT MEET OR EXCEED THE RATING PF THE ASSEMBLY IN WHICH THE NEW 13.THE CORRECTION OF ANY DEFECTS SHALL SHALL
<br /> COMPLETED BY THE CONTRACTOR
<br /> rn MINIMUM OF 30" BELOW GRADE/ 6' BELOW FROST-LINE IN TRENCH, UNLESS 12.CONTRACTOR SHALL CLEAN ENTIRE SITE AFTER CONSTRUCTION SUCH THAT NO
<br /> PENETRATION IS PLACED. WITHOUT ANY ADDITIONAL CHARGE AND SHALL INCLUDE THE REPLACEMENT OR
<br /> THE REPAIR OF ANY OTHER PHASE OF THE INSTALLATION, WHICH MAY HAVE OTHERWISE NOTED. BACK FILL SHALL BE COMPACTED AS REQUIRED BY DEBRIS, PAPER, TRASH, WEEDS, BRUSH, EXCESS FILL, OR ANY OTHER
<br /> z 20.CONTRACTOR SHALL KEEP CONTRACT AREA CLEAN, HAZARD FREE, AND DISPOSE BEEN DAMAGED THEREIN. ARCHITECT/ENGINEER. DEPOSITS WILL REMAIN. ALL MATERIALS COLLECTED DURING CLEANING GENERAL NOTES
<br /> OF ALL DIRT, DEBRIS, AND RUBBISH. EQUIPMENT NOT SPECIFIED AS REMAINING OPERATIONS SHALL BE DISPOSED OF OFF-SITE BY THE GENERAL
<br /> w ON THE PROPERTY OF THE OWNER SHALL BE REMOVED. LEAVE PREMISES IN 14.CONTRACTOR SHALL PROVIDE AND INSTALL CONDUIT, CONDUCTORS, PULL WIRES, 11.ALL GROUND CONDUCTORS SHALL BE RUN AS STRAIGHT AND SHORT AS CONTRACTOR.
<br /> CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY BOXES COVER PLATES AND DEVICES FOR ALL OUTLETS AS INDICATED. POSSIBLE, WITH A MINIMUM 12" BENDING RADIUS NOT LESS THAN 90
<br /> a 13.ALL TREES AND SHRUBS WHICH ARE NOT IN DIRECT L CONTRACTOR.
<br /> WITH THE
<br /> 0 NATURE. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL ITEMS UNTIL DEGREES. IMPROVEMENTS SHALL BE PROTECTED BY THE GENERAL CONTRACTOR.
<br /> o COMPLETION OF CONSTRUCTION. 15.DITCHING AND BACK FILL: CONTRACTOR SHALL PROVIDE FOR ALL UNDERGROUND
<br /> u INSTALLED CONDUIT AND/OR CABLES INCLUDING EXCAVATION AND BACKFILUNG 12.ACCEPTABLE CONNECTIONS FOR GROUNDING SYSTEM SHALL BE: 14.ALL SITE WORK SHALL BE CAREFULLY COORDINATED BY GENERAL
<br /> z 21.MINIMUM BEND RADIUS OF ANTENNA CABLES SHALL BE IN ACCORDANCE WITH AND COMPACTION. REFER TO NOTES AND REQUIREMENTS EXCAVATION,AND
<br /> CABLE MANUFACTURERS RECOMMENDATIONS. BACKFlLLING. A BURNDY, HY-GRADE U.L. LISTED CONNECTORS FOR OUTDOOR USE OR CONTRACTOR WITH LOCAL UTILITY COMPANY,TELEPHONE COMPANY,AND ANY SHEET NUMBER
<br /> F OTHER UTUTY COMPANIES HAVING JURISDICTION OVER THIS LOCATION.
<br /> AS APPROVED APPLICANT PROJECT MANAGER. /1
<br /> B. CADWELD, EXOTHERMIC WELDS (WELDED CONNECTIONS). /V= _
<br /> z C. ONE (1) HOLE TINNED COPPER COMPRESSION (LONG BARREL)
<br /> FITTINGS.
<br /> w
<br />
|