Laserfiche WebLink
Installation <br /> qualified installers only) 17 <br /> Exhaust Restrictor Extender (for rear vent configurations only) <br /> • Follow the directions below to install the exhaust restrictor extender. <br /> Remove these two screws <br /> on the exhaust restrictor. <br /> Firebox Roof <br /> Cc <br /> U <br /> Back Wa//of Firebox <br /> Exhaust Restrictor Extender Plate <br /> (included in the rear vent kits) <br /> Use the screws to attach <br /> 0 <br /> o the extender to the <br /> exhaust restrictor. <br /> Measuring Vent Lengths <br /> Vent Vent Horizontal Run is <br /> Horizontal measured from the start of <br /> Run the horizontal section to the <br /> end of the termination. <br /> Vent Height is calculated to H2 \ Vertical Elbow <br /> the top of the vent on \ <br /> horizontal terminations and Horizontal NOTE: <br /> to the top of the termination Elbow _� when a horizontal elbow(90°or 45°)is <br /> on vertical terminations. \ used,horizontal length is the sum of the <br /> two lengths(H1+H2). <br /> Vent H1 <br /> Vertical Elbow <br /> Height <br /> ©Travis Industries 4/19/23- 1443 Greenfield GSR2 <br />