Laserfiche WebLink
• Installation (for qualifiedinstallers • ■ <br /> Closing the Diffuser <br /> IMPORTANT NOTE: The diffuser can be easily closed with no vent in place. Consult the vent <br /> configuration charts to determine diffuser position. If the diffuser needs to be in the closed position, <br /> adjust the diffuser prior to installing vent. <br /> • To close the diffuser, reach into the vent starter section and bend the diffuser back (see photos <br /> below). You may need a screwdriver to bend the upper portion of the diffuser 90' (see photos <br /> below). <br /> Diffuser Open (stock— position # 1) Diffuser Closed (position #2) <br /> Closing the Diffuser After Vent is Installed <br /> • The diffuser may be removed from within the firebox and bent into the closed position . This <br /> requires removal of the burner, fireback shelf, and rear firebox wall (rivet cover). Once removed, <br /> the diffuser may be removed from below, bent 90°, and re-installed. See the illustration below. <br /> The diffuser is found on the inner flue assembly d the round portion of the <br /> (see Top to Rear Vent Configuration for details). Ben <br /> diffuser so it is bent(position#2). <br /> DIFFUSER SIDE VIEW <br /> Bottom of inner 1 1 <br /> Inner flue assembly flue assembly /T_-_ Before(Stock-Position#1) <br /> a QQ <br /> After(Position#2) <br /> 0ED <br /> Remove the Replace the <br /> diffuser. diffuser. <br /> 00 <br /> ©Travis Industries 4/19/23- 1443 Greenfield GSR2 <br />