Laserfiche WebLink
SYSTEM SUMMARY STC (12.470 kW DC / 10.121 kW AC) INTERCONNECTION 120% RULE EXTREME CASE MODULE OUTPUT <br /> STC DC: (29)430W= 12.470 kW (MAIN PANEL) (SILFAB SOLAR INC. SIL-430 QD) <br /> STC AC: (29)349W= 10.121 kW <br /> • (29)SILFAB SOLAR INC.SIL-430 QD MODULES Isc(25°C)= 13.87A,Tisc=0.040%/°C <br /> • (29)ENPHASE ENERGY INC. IQ8A-72-2-US[240V] MICROINVERTERS INTERCONNECTION 120°/D RULE Isc(T)=Isc(25°C)x[1 +Tisc x(T-25°C)] <br /> 88 Isc(26°C)= 13 70A, . A <br /> • 2x BRANCHES OF 10 CONNECTED IN PARALLEL NOT APPLICABLE Isc(-6°C)= 13. 'Y',JLN <br /> • 1x BRANCH OF 9 CONNECTED IN PARALLEL Voc(25°C)=38.91 V,Tvoc=-0.240%/°C ��C L C C T R I C <br /> LINE-SIDE TAP DOES NOT AFFECT Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] <br /> MAIN PANEL Voc(-6°C)=41.80V,Voc(26°C)=38.82V <br /> CONTRACTOR:ARTISAN ELECTRIC <br /> ADDRESS:969 S NEBRASKA STREET SUITE A <br /> SEATTLE,WA 98108,USA <br /> PHONE:12065491307 <br /> EMAIL:geoR.veslman@aaisaneledricinc.wm <br /> LICENSE#:ARTSE1878DN <br /> ELECTRICAL LICENSE#:ARTSE1936L1 <br /> MOD: SILFAB SOLAR INC.SIL-430 QD REVISIONS <br /> INV: ENPHASE ENERGY INC. DESCRIPTION DATE REV <br /> IQ8A-72-2-US[240V] <br /> (1 BRANCH X 10 MICRO-INV) <br /> 1 2 0 0 10 <br /> MS-01 MAIN SERVICE PANEL BI-DIRECTIONAL SIGNATURE&SEAL <br /> (EXISTING,TOP-FED) <br /> N ry 12 AWG Q-CABL BUS RATING:200A UTILITY METER <br /> 111734818 <br /> 06 AWG Cu BARE G (BOND RACKING) MAIN BREAKER:200A(E) METER NO: <br /> UTILITY:SNOHOMIHOMISH <br /> IQ COMBINER 5 COUNTY PUD NO 1 <br /> MOD: SILFAB SOLAR INC.SIL-430 QD TO CONSUMPTION CT SERVICE:240V 60HZ 1 PH <br /> INV: ENPHASE ENERGY INC. PV VISIBLE LOCKABLE <br /> IQ8A-72-2-US 240V JUNCTION BOX 200A( ) O TO <br /> [ l LABELED DISCONNECT <br /> (1 BRANCH X 10 MICRO-INV) 600V, NEMA 3R GATEWAY (60A FUSED 1 PH 240VAC) CT UTILITY <br /> UL LISTED CT i <br /> A LC-01HOMEOWNER INFO <br /> 1 2 ° 0 10 MCB-01 20N) 60A(N) LC-02 <br /> MCB-01 20A(N) <br /> MCB-02 20A(N) <br /> MS-01 ON OFF QO M <br /> CD <br /> 12 AWG Q-CABL - Q N <br /> 06 AWG Cu BARE G (BOND RACKING) > E <br /> + ° <br /> MOD: SILFAB SOLAR INC.SIL-430 QD w z E <br /> INV: ENPHASE ENERGY INC. ~ O I j <br /> IQ8A-72-2-US[240V] _� ~ of Q a A <br /> 1 BRANCH X 9 MICRO-INV LU ? L <br /> ( ) GROUND ROD o <br /> 1 2 9 z w o <br /> 2 F � J <br /> U oQ <br /> rn <br /> MS-02 O w <br /> Un <br /> 12 AWG Q-CABL cM cy) o <br /> 06 AWG Cu BARE G (BOND RACKING) L d <br /> O Q <br /> co <br /> SHEET NAME <br /> AC wire details SINGLE LINE <br /> ELECTRICAL NOTES Wire Min Ampacity Live Neutral Ground Min EMT Min PVC Min RMC DIAGRAM <br /> 1) ALL GROUNDING TO COMPLY WITH NEC 690.47. MS-01 18.13A 12 AWG(Q-Cable) 06 AWG BARE <br /> 2) ROOFTOP CONDUIT SHALL BE LOCATED MIN.7/8"ABOVE ROOF SURFACE. (NOT IN CONDUIT) <br /> 3) ALL TERMINALS SHALL BE MIN.75°C RATED. 06 AWG BARE SIZE <br /> 4) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER(10A or 15A). MS-02 16.31A 12 AWG(Q-Cable) (NOT IN CONDUIT) I ANSI B <br /> 5) FOR IQ GATEWAY: USE SINGLE CT FOR PV PRODUCTION(L1 FROM ALL PV BRANCH CIRCUITS). USE DOUBLE CTs FOR MCB-01 18.13A (2) 10 AWG THWN-2 10 AWG THWN-2 1/2 in 1/2 in 1/2 in 11" X 17" <br /> CONSUMPTION(L1 AND L2 FEEDING MSP MAIN BREAKER,SERVICE SIDE). MCB-02 16.31A 1 (2) 10 AWG THWN-2 10 AWG THWN-2 1/2 in 1/2 in 1/2 in <br /> LC-01 52.56A (2)06 AWG THWN-2 06 AWG THWN-2 10 AWG THWN-2 3/4 in 3/4 in 3/4 in SHEET NUMBER <br /> pp <br /> ELECTRICAL SINGLE LINE DIAGRAM LC-02 52.56A (2)06 AWG THWN-2 1 06 AWG THWN-2 06 AWG THWN-2 - 1 in 1 in PV-4 <br /> SCALE: NTS <br />