SYSTEM SUMMARY STC (12.470 kW DC / 10.121 kW AC) <br /> STC DC: (29)430W= 12.470 kW <br /> STC AC: (29)349W= 10.121 kW <br /> • (29)SILFAB SOLAR INC.SIL-430 QD MODULES � - <br /> • (29)ENPHASE ENERGY INC. IQ8A-72-2-US[240V] MICROINVERTERS <br /> • 2x BRANCHES OF 10 CONNECTED IN PARALLEL ARTISAN <br /> • 1x BRANCH OF 9 CONNECTED IN PARALLEL C L C CTR I C <br /> CONTRACTOR:ARTISAN ELECTRIC <br /> ADDRESS:969 S NEDRASKA STREET SUITE A <br /> SEATTLE,WA 98108,USA <br /> PHONE:12065491307 <br /> EMAIL:geoff.vestman@artisanelectricinc.com <br /> LICENSE#:ARTSE1878DN <br /> ELECTRICAL LICENSE*ARTSE1936L1 <br /> REVISIONS <br /> DESCRIPTION DATE REV <br /> AC wire details SIGNATURE&SEAL <br /> WirelD #Modules Nominal Backfeed*1.25 Min Total Conductor ccConductors Expected Adjusted ampacity(ampacity x temp Conductor& EGC size Conductor Max V drop Min EMT Min PVC Min RMC <br /> Voltage /cond.set OCPD Power sets /conduit max temp derate x conduit fill derate) neutral size (Cu) metal length size size size <br /> MS-01 10 240 V 18.13 A 20 A 3.5 kW 1 2 26 25 x 1.00 =25.00 A 12 AWG(Q-Cable) 06 AWG BARE Cu 50 ft 1.02% <br /> (NOT IN CONDUIT) <br /> MS-02 9 240 V 16.31 A 20 A 3.1 kW 1 2 26 25 x 1.00 =25.00 A 12 AWG(Q-Cable) 06 AWG BARE Cu 50 ft 0.92% <br /> (NOT IN CONDUIT) <br /> MCB-01 10 240 V 18.13 A 20 A 3.5 kW 1 1 1 2 1 26 1 35 x 1.00 x 1.00=35.00 A 10 AWG THWN-2 10 AWG THWN-2 Cu 50 ft 0.61 % 1/2 in 1/2 in 1/2 in <br /> MCB-02 9 240 V 16.31 A 20 A 3.1 kW 1 2 26 35 x 1.00 x 1.00=35.00 A 10 AWG THWN-2 10 AWG THWN-2 Cu 50 ft 0.55% 1/2 in 1/2 in 1/2 in <br /> LC-01 29 240 V 52.56 A 60 A 10.1 kW 1 2 26 1 65 x 1.00 x 1.00=65.00 A 06 AWG THWN-2 10 AWG THWN-2 Cu 10 ft 0.14% 3/4 in 3/4 in 3/4 in HOMEOWNER INFO <br /> LC-02 29 240 V 52.56 A 60 A 10.1 kW 1 2 26 1 65 x 1.00 x 1.00=65.00 A 06 AWG THWN-2 06 AWG THWN-2 Cu 10 ft 0.14% 1 in 1 in <br /> N rn <br /> INTERCONNECTION 120% RULE EXTREME CASE MODULE OUTPUT 00 Cl) <br /> CD <br /> (MAIN PANEL) (SILFAB SOLAR INC. SIL-430 QD) rn LO <br /> U Q <br /> N <br /> Isc(25°C)= 13.87A,Tisc=0.040%/°C > o <br /> INTERCONNECTION W> + U <br /> D Isc(T)= Isc(25°C)x[1 +Tisc x(T-25°C)] <br /> 120/o RULE UJ <br /> Isc(-6°C)= 13.70A, Isc(26°C)= 13.88A <br /> z uJ Y <br /> NOT APPLICABLE <br /> Voc(25°C)=38.91V,Tvoc=-0.240%/°C O <br /> = � <br /> LINE-SIDE TAP DOES NOT AFFECT Voc(T)=Voc(25°C)x[1 +Tvoc x(T-25°C)] of W < 0- A <br /> MAIN PANEL Voc(-6°C)=41.80V,Voc(26°C)=38.82V LU U) o U? <br /> z W o <br /> 2 ~ "tJ <br /> U) o a <br /> ELECTRICAL NOTES O w <br /> o <br /> 1) ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL,AND LABELED FOR ITS APPLICATION. C0 o <br /> 2) ALL CONDUCTORS SHALL BE COPPER,RATED FOR 600V AND 90°C WET ENVIRONMENT. Z <br /> LID 0- <br /> 3) WIRING,CONDUIT,AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO,AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE,HIP,OR VALLEY. O < <br /> 4) WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26. (0 <br /> 5) DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS,FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. <br /> 6) WHERE SIZES OF JUNCTION BOXES,RACEWAYS,AND CONDUITS ARE NOT SPECIFIED,THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br /> 7) ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. SHEET NAME <br /> 8) MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME AND MODULE SUPPORT RAIL,PER THE GROUNDING CLIP MANUFACTURER'S INSTRUCTION. <br /> 9) MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER G.E.C.VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. WIRING <br /> 10) PV EQUIPMENT SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NEC 690. <br /> 11) EXACT LOCATION OF AUXILIARY GROUNDING TO BE DETERMINED AT TIME OF INSTALL. CALCULATIONS <br /> 12) EXISTING WIRES MUST BE REPLACED IF SMALLER THAN LISTED MINIMUM SIZES PER NEC 310.15(B)(16). <br /> 13) IQ GATEWAY BREAKER DETERMINED AT FACTORY BY MANUFACTURER(10A or 15A). <br /> 14) FOR IQ GATEWAY:USE SINGLE CT FOR PV PRODUCTION(L1 FROM ALL PV BRANCH CIRCUITS).USE DOUBLE CTs FOR CONSUMPTION(L1 AND L2 FEEDING MSP MAIN BREAKER,SERVICE SIDE). SIZE <br /> ANSI B <br /> 11" X 17" <br /> PP SHEET NUMBER <br /> WIRING CALCULATIONS PV-5 <br /> SCALE: NTS <br /> r` <br /> i <br />
The URL can be used to link to this page
Your browser does not support the video tag.