FLOOR PLAN NOTES <br />I. CONTRACTOR SHALL VERIFY ALL NOTES, MATERIALS 4 CONDITIONS PRIOR TO <br />CONSTRUCTION. <br />WINDOWS It DOORS: <br />2. ALL EXTERIOR WINDOW t DOOR HEADERS TO BE INSULATED w/ R-10 INSULATION. <br />3. WINDOWS 4 DOORS ARE SHOWN 4 NOTED AS NOMINAL SIZES. <br />4. WINDOW HEAD HEIGHT R.O. SHOWN PER ELEVATIONS. EGRESS WINDOW SILL. HEIGHT R.O. @ <br />MAX. 42' A.F.F. <br />5. ALL WOOD IN CONTACT WITH CONC. TO BE PRESSURE TREATED, <br />6. EXTERIOR WALLS TO BE 26 STUDS @ Ib' O.C., U.NO. <br />T GARAGE DOOR HEADERS @ 84' A.F.F. <br />8. EXTERIOR SWING DOOR HEADERS @ 83 1/2' A.F.F. <br />9. INTERIOR SWING DOOR HEADERS @ 83' A.F.F. <br />10. SWING DOORS TO FOLLOW CENTERLINE DIMENSION IN PLANS QR BE 3" MIN, ON HINGE SIDE. <br />11. GARAGE -TO -HOUSE DOOR TO BE A SOLID WOOD I%' THICK 20-MINUTE FIRE -RATED DOOR <br />w/ A SELF CLOSING HARDWARE DEVICE. <br />12. PER R311.3.11 THE LANDING OR FLOOR ON THE EXTERIOR SIDE OF ALL EXTERIOR DOOR5 <br />EXCEPT THE FRONT DOOR SHALL BE NOT MORE THAN 7-3/4' BELOW THE TOP OF THE <br />THRESHOLD PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR <br />13. ALL BI-FOLD 4 BI-PA55 DOORS TO BE CENTERED, U.N.O. <br />FRAMING: <br />14. VERIFY FIREPLACE STYLE 4 LOCATION w/ SUPERVISOR PRIOR TO CO',51 <br />15. FRAMERS TO INSTALL ALL WINDOWS 4 INTERIOR COLUMNS <br />16. TOWEL RING BLK'G @ 57' A.F.F. <br />17. TOWEL BAR BLK'G @ 48' A.F.F. 4 BLOCK BOTH BAYS. <br />18. TOILET PAPER HOLDER BLK'G @ 22' A.F.F. AND 42" FROM BACK WALL WHERE POSSIBLE <br />19. THERMOSTAT BLK'G @ 60' A.F.F <br />20. EXTERIOR LIGHT BLOCKS AT ALL FRONT ENTRY'S SHALL BE 11151ALLED AT 7'-6" A.F.F. <br />21. THE TOP Of THE EXTERIOR LIGHT BLOCKS AT GARAGE SHALL ALIGN WITH TOP OF THE <br />GARAGE DOOR TRIM <br />22. ADD CONT. BLOCKING FOR STAIR HANDRAIL BRACKETS <br />23. STAIRS w/ WINDER STEPS WILL ALWAYS HAVE A CONTINUOUS HANDRAIL INSTALLED ON <br />THE INSIDE OF THE STAIR's RUN <br />24. LADDER -BLOCK AT EXTERIOR WALLS AS NECESSARY FOR INSULATION INSTALL <br />VENTILATION: <br />25. WHOLE HOUSE VENTILATION SHALL BE PROVIDED BY A CENTRAL EXHAUST FAN IN <br />ACCORDANCE WITH M1505.4.1.1. <br />26. WHOLE HOUSE FAN 514ALL OPERATE CONTINUOUSLY, <br />27. WHOLE HOUSE FAN CFM RATE BASED ON TABLE M1505.4.3(1). EXAMPLE. 70 CFM FOR 2600 <br />SF HOME w/ 4 BEDROOMS, AND THEN INCREASE BY FACTOR OF 1.5 PER TABLE <br />M1505.4.3(2) TO ACCOUNT FOR NOT -BALANCED, NOT -DISTRIBUTED VENTILATION SYSTEM. <br />28, WHOLE HOUSE FAN SHALL BE 1.0 50NES OR LESS, AND SHALL HAVE AN EFFICACY OF 2.5 <br />CFM / WATT PER WSEC R403.6.1. <br />29. FRESH AIR SHALL BE INTRODUCED INTO THE HOUSE VIA OPERABLE WINDOWS PER STATE <br />CODE INTERPRETATION 17-15. <br />30. PROVIDE A FRESH AIR TRANSFER GRILL ABOVE DOOR HEADER IN THE ROOM WITH THE <br />WHOLE HOUSE FAN. <br />31, PER IRC M1502.4.5.: WHERE THE DRYER VENT EXHAUST DUCT 15 CONCEALED WITHIN THE <br />BUILDING CONSTRUCTION, THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL BE <br />IDENTIFIED ON A PERMANENT LABEL OR TAG. THE LABEL OR TAG SHALL BE LOCATED <br />WITHIN GIFT OF THE EXHAUST DUCT CONNECTION. <br />LIFE SAFETY: <br />26. A HEAT ALARM OR HEAT DETECTOR RATED FOR AMBIENT OUTDOOR TEMPERATURES AND <br />HUMIDITY TO BE CENTRALLY LOCATED IN THE GARAGE. <br />27. THE HEAT ALARM OR HEAT DETECTOR WILL BE CONNECTED TO AN ALARM OR SMOKE <br />ALARM THAT 15 INSTALLED IN THE DWELLING AND LOCATED IN A HALLWAY, ROOM OR <br />OTHER LOCATION THAT WILL PROVIDE OCCUPANT NOTIFICATION <br />10, SMOKE DETECTORS TO BE IIOV, INTERCONNECTED, w/ BATTERY BACKUP t CENTRALLY <br />LOCATED IN EACH HABITABLE ROOM. ADDITIONAL SMOKE DETECTORS SHALL BE <br />INSTALLED WHERE THERE 15 A CEILING HEIGHT CHANGE GREATER THAN 24 <br />11. SMOKE DETECTORS SHALL BE INSTALLED NOT LESS THAN 3 FT HORIZONTALLY FROM THE <br />DOOR OR OPENING OF A BATHROOM THAT CONTAINS TUB OR SHOWER. LP314i <br />12. IONIZATION SMOKE ALARMS: <br />I SHALL NOT BE INSTALLED LE55 THAN 20 FT HORIZONTALLY FROM A PERMANENTLY <br />INSTALLED COOKING APPLIANCE. <br />+ IONIZATION SMOKE ALARMS WITH AN ALARM -SILENCING SWITCH SHALL NOT BE INSTALLED <br />LESS THAN 10 FT HORIZONTALLY FROM A PERMANENTLY INSTALLED COOKING APPLIANCE. <br />24, PHOTO ELECTRIC SMOKE ALARMS SHALL NOT BE INSTALLED LESS THAN 6 FT <br />HORIZONTALLY FROM A PERMANENTLY INSTALLED COOICPNG APPLIANCE TR3143 <br />25. GARAGE NOTE: WRAP ALL WARM WALLS AND SUPPORTING MEMBERS WITH 1/2' G.W.B. 4 5/8' <br />TYPE 'X' ON THE CEILING. POLY SEAL RIM, ENTIRE GARAGE TO MEET JURISDICTION <br />DRAFT STOP REQUIREMENTS <br />26. ENCLOSED USABLE SPACE UNDER STAIRS TO BE PROTECTED WITH )¢" GWB AT THE <br />WALLS, UNDER -STAIR SURFACES AND SOFFITS. <br />27. PROVIDE FIREBLOOKING PER PLAN AND @ ALL PLUMBING PENETRATIONS. <br />I. - <br />t EQ. <br />- ' <br />NJ DOOR <br />ZH tmu <br />PER PLAN <br />Ice ua: <br />.�. ___ <br />-- <br />cw <br />�RONTPCfCW,5LAB <br />aH L100R <br />ELEVATION- <br />4' 0' <br />'j PLATE a <br />ADI THRESHOLD <br />RAISED WALL, <br />RIPPED TJ:.'. <br />__ _ _ <br />(2)214b TO BE <br />REMOVED PRIOR <br />is SUE-FLG.'i: <br />2x HUH. <br />TOE KIL% - <br />TO FRLNT <br />STEP/WALK BEING <br />PER <br />,ILOG PAVER <br />BTWN JOISTL----- -' <br />END 4 CONC <br />N- " <br />PIA I <br />WAIL dEYONC'-' <br />R;ISED _ <br />FRONT PORCH FRONT <br />SLAB. SLOPE PORCH <br />+ T.O. RAISED <br />STEM WALL TO <br />Ir'SECT UN TE^I <br />�" PER uN. WALL +STEM <br />FT. <br />T.O. FRONT PORCH <br />I_-_� >;ALL • -.. <br />STEM KILL - 7' <br />(D38FRON 1 <br />PORCH EXT. <br />DETAIL <br />�... SCALE. I,11_" <br />• 1'-0' <br />SGD PER PLAN <br />RABLE <br />FIXED <br />-RAB4NEL <br />PANEL <br />LINE VP -- <br />NERVESTRAL -, t,________ <br />BEHIND I <br />BOTTa uF EQ. <br />SIDING <br />--- <br />I <br />EQ. <br />NE <br />FRG .)RCH' <br />PATIO' <br />:' LANDING TYP. <br />y <br />W, - BACK PATIO's <br />2xi HEARTWOOD CEDAR TRIM, <br />EO. ALL SIDES, CADLK/SFAL <br />3 xS' LANDING TIP. <br />OUR AGAINST <br />-2x6 HEARTWOOD CEDAR TRIM <br />DOOR __. .. �..... LANDING PER PLAN, POUR <br />THRESH0.L / AGAINST NERVESTRAL 2.6 HEARTWOOD CEDAR <br />TRIM w/ FLASHING P <br />MERVFSTR.IL- I "ll INTERSECTION, <br />4HDII4 PER PLAN, I _ _ WHERE OCCURS <br />N. 3u" TYP) <br />OF STEPS�TB(Y By LINE Of NERVESTRAL <br />MIiD SILL-� E CONDITIONS _ <br />CCNC. WALL -_®� SLAB ON GRADE. - -. <br />I _... AmraoEr�uL <br />EXT. I ANDING DETAIL @ <br />C- 5LIDI1I1- GLASS DOOR, TYP <br />12�xALE Il <br />DRI`',� '/PORCH PLAN <br />SCALE: 3/8' - I'-0" <br />DOOR t JAMBj <br />CAULK BACK OF <br />THRESHOLD TO WRAP NERVASTRAL <br />NERVESTRAL UP JAMB 6' <br />4 ALL SEAMS (2) V BEADS OF <br />CAULK UNDER <br />-- __ _ _ NERVE5TRAL, (1) <br />WRA4 @ SIDES OF JAMB <br />THRE/ <br />ADD'L NERVASTRAIL NERVASTRAL OR EO <br />THRESHOLD DETAIL <br />V"I SCALE: 1-1/2' = 1'-0" <br />7' <br />D25 <br />12 <br />b ELECTRIC <br />u, FIREPLACE <br />L�z <br />ELECTRIC <br />FIREPLACE OPT. <br />SCALE: 1/4' - 1'-0' <br />(2) 2436° HEAT <br />PUMP BASES. <br />WHEN GARAGE <br />jN12 <br />OPT. SELECTED, <br />� <br />STEP <br />VERIFY LOCATION <br />3'x3'6 CONC, <br />SUPER <br />LANDING <br />6046 <br />XO <br />506E SGD <br />(SG) <br />L6J <br />ACTIVE (FOR MINI-S LIT ACTIVE <br />BATH FAN VENT <br />CLEARANCE) NOOK <br />9 6_x '5 <br />2CM OVERHANGS TO BE 5" It <br />GREAT ROOM 3CM OVERHANGS TO BE <br />131xl5'9 34Y44'Hx 9'-1¢°1_ 2x4 @24° <br />-1 <br />WALL PLACE DRYWALL <br />- <br />CPT ON SINK E 9'4" <br />45 <br />I° <br />SD/CO <br />INSTALL (2) <br />Il <br />24 STACKED <br />BLKNG FOR <br />RANGE HOOD <br />BOTH SIDES <br />V-5' 4'-0' 5'-9' r - <br />_ I D/W a I <br />I <br />OF CENTER <br />JN <br />STUD R t0" <br />DW AIR LL <br />W/S(I TR J GAP DINITCHEN 5 ®p <br />CENTER <br />-- CPr 246E 266E SIDE 10'4)(13'S - <br />STUD BAY <br />_ <br />- <br />IB'x24" CRAWL <br />1 /• H5 _ E 7 <br />ON RANGE <br />ACCESS <br />BF <br />12x5' <br />SEE CAB <br />E02068 <br />EQ <br />LINE OF :u <br />2'_5'�' FLOOR ABOVE <br />LAYOUT <br />FOR LOC - <br />TP W/50) OPN'G <br />KNEE WALL <br />° 'STAIRS w/ WINDERcl <br />�, <br />_ <br />q <br />BELOW <br />_: STEPS WILL ALWAYS <br />yT NAVE A CONTINUOUS STEP _ �q y.q ` <br />HANDRAIL INSTALLED n 'I WH., 3' <br />HWT TO BE <br />INSTALLED IN <br />T <br />'° <br />sr ON THE INSIDE OF 5'- ' _ ° LR ; <br />3 T 3 O' <br />THE 3rd CAR <br />'^ <br />° - THE STAIR RUN <br />UN <br />GARAGE OR <br />j <br />OPEN 4' BOLLARDL <br />ABOVE <br />BUMP-OUT WHEN <br />THAT OPT, IS <br />SELECTED. <br />15R,14T S GARAGE <br />17'3x10'9 <br />WRAP ALL WARM WALLS, POSTS, <br />LINE OF BEAMS 4 SUPPORT WALLS W/ 1/2' <br />3'-Il1x" s FLOOR G.W.B. 4 5/8' TYPE "X' ON THE <br />- ABOVE CEILING <br />JSD ay <br />_ <br />g Oo <br />- <br />3 DEN <br />T 7'2XI0'3 <br />a <br />1 <br />fir" q,�� Ln <br />W5 <br />AIO <br />AQ <br />FOR <br />1 <br />r r <br />UTILITY <br />LAYOUT, <br />SEE <br />194 FRON <br />_ <br />PORC - = 15070 GARAGE DOOR Tn' <br />EXTENDED FRONT PORC� <br />OPTION - 'A' ELEV. <br />SCALE: 1/4' - I'-O' <br />MAIN FLOOR PLAN - 'A' ELEV. <br />SCALE: 1/4' = I'-0' <br />COPYRIGHT NOTICE: THIS <br />PLAN 15 OWNED BY PACIFIC <br />RIDGE HOMES. 115E OF THIS <br />PLAN 15 PROHIBITED BY LAW <br />WM40UT PAYMENT OF <br />LICENSE FEE TO PACIFIC <br />RIDGE LOTFS. <br />PLAN SUMMARY <br />N/A <br />1881 w M <br />ANVE WRA. ", <br />424 <br />ELECTRIC <br />uw+s w N.we rm�uim <br />JWA <br />B LT ENGINEERING <br />SEE REVISION LOG <br />SCALE: Y.' = 1'-0' <br />MAIN FLOOR PLAN <br />