Earthwork Solutions, LLC 1/30/2025
>
Contracts
>
10 Years Then Transfer to State Archivist
>
2025
>
Earthwork Solutions, LLC 1/30/2025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/4/2025 1:40:20 PM
Creation date
2/4/2025 1:26:02 PM
Metadata
Fields
Template:
Contracts
Contractor's Name
Earthwork Solutions, LLC
Approval Date
1/30/2025
Council Approval Date
9/11/2024
End Date
12/31/2025
Department
Public Works
Department Project Manager
Laura Claywell
Subject / Project Title
FULTON STREET PEDESTRIAN BICYCLE CORRIDOR
Public Works WO Number
3785
Tracking Number
0004652
Total Compensation
$0.00
Contract Type
Capital Contract
Contract Subtype
Capital Construction Contracts and Change Orders
Retention Period
10 Years Then Transfer to State Archivist
Imported from EPIC
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Download electronic document
View images
View plain text
<br />Fulton Street Pedestrian Bicycle Corridor PAGE 101 OF 114 CONTRACT <br />FEDERAL AID # TAP-0420(026) <br />WO #3785 September 6, 2024 <br /> <br />then be carefully painted with hot asphalt cement or asphalt emulsion and shall be 1 <br />immediately covered with dry paving sand before the asphalt cement solidifies. 2 <br /> 3 <br />The inside throat of the structure shall be thoroughly mortared and plastered through 4 <br />to the outside of the structure’s concrete adjustment rings. 5 <br /> 6 <br />Castings that need replacement shall be identified by the City of Everett. 7 <br />Replacement casting will be supplied by the City of Everett and original casting will 8 <br />be picked up by the City of Everett. 9 <br /> 10 <br /> 11 <br />GLF 7-05.3(5).DOCX 12 <br />Adjusting Valve Boxes to Grade 13 <br />(******) 14 <br /> 15 <br />Section 7-05.3 of the standard specifications is supplemented with the following: 16 <br /> 17 <br />(******) 18 <br />Adjustment of valve boxes to grade shall occur only as needed and/or directed by 19 <br />the engineer. Existing valve boxes and covers shall be adjusted to the grade as 20 <br />staked or otherwise designated by the Engineer. The adjustment of the valve box to 21 <br />grade by the use of riser rings is not allowed. 22 <br /> 23 <br />Removal operations shall be conducted to prevent damage to the valve boxes. Any 24 <br />parts or materials damaged due to the Contractor's operations shall be replaced at 25 <br />the Contractor’s expense. Castings that need replacement shall be identified by the 26 <br />City of Everett. 27 <br /> 28 <br />The Contractor shall conduct the valve box adjustments so that the fully -adjusted box 29 <br />allows the respective valve to be fully operational. The Contractor shall remove all 30 <br />debris from the adjusted valve boxes to ensure such operational condition. 31 <br /> 32 <br /> 33 <br />GLF 7-05.4.DOCX 34 <br />7-05.4 Measurement 35 <br /> 36 <br />Section 7-05.4 of the standard specifications is deleted and replaced with the following: 37 <br /> 38 <br />(******) 39 <br />“Adjust Catch Basin/Inlet to Grade”, shall be measured per each. 40 <br /> 41 <br />“Adjust Valve Box to Grade”, shall be measured per each. 42 <br /> 43 <br /> 44 <br />GLF 7-05.5.DOCX 45 <br />7-05.5 Payment 46 <br /> 47 <br />Section 7-05.5 of the standard specifications is deleted and replaced with the following: 48
The URL can be used to link to this page
Your browser does not support the video tag.