My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
711 91ST PL SE 2025-04-23
>
Address Records
>
91ST PL SE
>
711
>
711 91ST PL SE 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 1:36:13 PM
Creation date
2/6/2025 1:48:54 PM
Metadata
Fields
Template:
Address Document
Street Name
91ST PL SE
Street Number
711
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> December 30, 2014 <br /> T. Kissenford <br /> 711 91st PI SE <br /> Everett, WA 98208 <br /> Subject: Project: Kissenfors <br /> Job Address: 711 91st PI SE <br /> Plan Check No: CW1412-001 <br /> Dear Mr. Taylor: <br /> In response to your application for a construction permit, your plans have been examined and <br /> you are advised that the issuance of a permit is being withheld for the reasons listed below. <br /> These comments address building issues only. Additional revisions or additions may be <br /> required by other departments (such as Utilities, Planning or Fire). All references refer to the <br /> (2012 International Building Code,) (2012 International Residential Code,) as amended by the <br /> State of Washington and/or Washington State Energy Code 2012 Edition, and adopted by the <br /> City of Everett, unless stated otherwise. <br /> In order for the processing of your application to continue, it will be necessary to <br /> provide the Building Division with two new complete sets of drawings reflecting the <br /> corrections requested, along with a reduced set of plans no larger than 11"x 17". <br /> 1. Provide stair section and details for both new stairs. Provide min 36"landing at the top <br /> and bottom of all stairs. <br /> 2. Provide 110 volt smoke alarms, interconnected with battery back-up per section R314 <br /> International Residential Code (IRC). Show all locations on plan view. <br /> 3. Provide carbon monoxide alarms per R315 IRC. Show on plans. <br /> 4. Specify minimum egress requirements in all bedrooms. The windows in the south east <br /> corner of the house on the upper floor appear to be smaller than the minimum size <br /> required for egress per section R310 of the IRC. <br /> 5. Detail connection of addition to existing structure at roofline. Show how addition is <br /> flashed for the prevention of water intrusion at the addition. <br /> 6. The cross section shown on sheet A302 does not meet the minimum requirement for a <br /> thermal break per WA State Energy Code (WSEC), does not show R-21 insulation on the <br /> interior of concrete stem wall and is not consistent with what was built prior to permit <br /> application. <br /> S:\1Common\Clerical\JHeilman\!Heilman permit response.doc 1 J L <br />
The URL can be used to link to this page
Your browser does not support the video tag.