711 91ST PL SE 2025-04-23
>
Address Records
>
91ST PL SE
>
711
>
711 91ST PL SE 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 1:36:13 PM
Creation date
2/6/2025 1:48:54 PM
Metadata
Fields
Template:
Address Document
Street Name
91ST PL SE
Street Number
711
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
81
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> 7. Provide gravity calculations for 4x6 post supporting 5.5 x 13.5 glue laminated beam. <br /> 8. Specify length and spacing of dowels connecting new foundation to existing residences. <br /> 9. Decks shall be designed for both vertical and lateral loads (R507.2.3 (2)) IRC. Show <br /> location and specify connections proposed to resist lateral loads. <br /> 10. Ledger attachment shown on the plans calls for a minimum 6x blocking in full height <br /> ' studs. Provide detail for platform framing with attachment to rim joist. Specify <br /> placement of lag screws and/ or bolts in ledger per figure R507.2.1 (1) IRC. Show on <br /> plans. <br /> 11. Provide deck section and/ or detail (s) specific to this structure. Specify all components <br /> including joist hangers, guard height, attachment, material, blocking (at guard) blocking <br /> (for overturning). <br /> 12. Provide footing(s) supporting landing and stairs on the west side or proposed addition. <br /> Show on plans. <br /> 13. Specify minimum u-value for all new fenestration equals u-0.3p or less. Per table <br /> R402.1.1 WSEC. <br /> 14. Specify which option from table 406.2"Energy Credits", you are using to get the 0.5 <br /> credits required for compliance with the WA State Energy Code. Show option chosen on <br /> the plans include the minimum equipment efficiency and (if required) flow rate. <br /> 15. Show all steps on plan view. <br /> 16. Show how spaces in addition are heated. <br /> Please prepare a response letter showing where each item in this correction letter is <br /> addressed on the plan set. <br /> Upon resubmittal of the drawings, your application will be given priority and plan review will <br /> recommence. <br /> All required submittals shall be of sufficient detail and contain sufficient information to ensure <br /> that the proposed structure will be constructed in compliance with all adopted codes. <br /> Sincerely, <br /> ° <br /> 1/7 f ja.„,--- <br /> 1, 11 <br /> Jeff Heilman <br /> Development Technician <br /> 425-257-8976 <br /> Email: jheilman©ci.everett.wa.us <br /> S:\1Common\Clerical\Hellman\IHellman permit response.doc Z I 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.