Laserfiche WebLink
SOLAR MODULE SPECIFICATIONS Voltage rise in Q Cable from the Microinverters to the Junction Box <br /> HANWHA Q CELL (Q.PEAK For branch circuit #1 of 12 IQ 7 Micros, the voltage rise on the 240 VAC Q Cable is 0.55% <br /> MANUFACTURER / MODEL DUO-G8+ 340W) g <br /> VMP 34.34 V For branch circuit #2 of 12 IQ 7 Micros, the voltage rise on the 240 VAC Q Cable is 0.55% <br /> IMP 9.90 A Voltage rise from the Junction Box to the IQ Combiner box <br /> voc 40.70 V VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft) <br /> ISC 10.40 A <br /> TEMP. COEFF. VOC -0. = (1 amp x12 ) x (0.002050 0/ft) x (30 ft x 2) <br /> - 12 amps x 0.002050 0/ft x 60 ft <br /> PTC RATING 318.35 W <br /> = 1 .48 volts EL <br /> MODULE DIMENSION 68.5" (L) x 40.5" (W) (24 ANW A IQ CEL <br /> L <br /> %VRise = 1 .48 volts _ 240 volts = 0.62% (Q.PEAKDUO-GS+340W) <br /> PANEL WATTAGE 340W (24)ENPHASE IQ7-60-2-US(240V) <br /> The voltage rise from the Junction Box to the IQ Combiner Box is 0.62% DC SYSTEM SIZE:8.16 KWDC <br /> AC SYSTEM SIZE:6.00 KWAC <br /> INVERTER SPECIFICATIONS REVISIONS <br /> MANUFACTURER/ MODEL EN PHASE IQ7-60-2-US(24OV) Voltage rise from the IQ Combiner box to AC Disconnect DESCRIPTION DATE REV <br /> MAX DC SHORT CIRCUIT VRise = (amps/inverter x number of inverters) x (resistance in 0/ft.) x (2-way wire length in ft.) <br /> CURRENT 15 A = (1 amp x 24) x (0.001290 0/ft) x (5 ft. x 2) <br /> CONTINUOUS OUTPUT = 24 amps x 0.001290 0/ft x 10 ft. Signature with Seal <br /> CURRENT 1.OA (240V) = 0.31 volts <br /> AMBIENT TEMPERATURE SPECS %VRise = 0.31 volts _ 240 volts = 0.13% <br /> RECORD LOW TEMP -5°C 0 DATE:08/10/2021 <br /> The voltage rise from the IQ Combiner Box to the AC Disconnect is 0.13 /o AMBIENT TEMP (HIGH TEMP 2%) 26°C PROJECT NAME&ADDRESS <br /> CONDUIT HEIGHT 0.5" Voltage rise from the AC Disconnect to the Main Service Panel <br /> ROOF TOP TEMP 900C VRise = (amps/inverter x number of inverters) x (resistance in 0/ft) x (2-way wire length in ft) <br /> CONDUCTOR TEMPERATURE RATE 480c = (1 amp x 24) x (0.000491 0/ft) x (5 ft x 2) (If o <br /> MODULE TEMPERATURE COEFFICIENT OF VOC -0.27 %/K = 24 amps x 0.000491 /ft x 10 ft W N <br /> LLJ o <br /> NUMBER OF CURRENT = 0.12 volts z Q o <br /> PERCENT OF VALUES CARRYING CONDUCTORS %VRise = 0.12 volts _ 240 volts = 0.05% w � �' <br /> IN EMT c2 <br /> 0.80 4-6 The voltage rise from the AC Disconnect to the Main Panel is 0.05% z J o <br /> 0.70 7-9 Q W - <br /> Total system voltage rise for all three wire sections � w a <br /> 0.50 10-20 y g � <br /> 0.55 % + 0.62% + 0.13% + 0.05% = 1 .35% Q <br /> SHEET NAME <br /> SPECIFICATIONS <br /> & CALC. <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-4A <br />