Laserfiche WebLink
Data Sheet Enphase IQ 7 and IQ 7+ Microinverters <br /> Enphase Microinverters <br /> Region:AMERICAS INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US <br /> Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ <br /> Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules <br /> Maximum input DC voltage 48 V 60 V <br /> Peak power tracking voltage 27 V-37 V 27 V-45 V <br /> Operating range 16 V-48 V 16 V-60 V <br /> Min/Max start voltage 22 V/48 V 22 V/60 V <br /> Max DC short circuit current(module Isc) 15 A 15 A <br /> Enphase The high-powered smart grid-ready Overvoltage class DC port 11 11 SYSTEM INFO. <br /> M and Enphase IQ 7+Micro DC port backfeed current 0 A 0 A (24)HANWHA QCELL <br /> Enphase IQ 7 Micro' M (Q.PEAKDUO-G8+340W) <br /> PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; <br /> Q 7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit (24)ENPHASE IQ7-60-2-US(240V) <br /> achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter DC SYSTEM SIZE:8.16 KWDC <br /> Microinverters Peak output power 250 VA 295 VA AC SYSTEM SIZE:6.00 KWAC <br /> Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA <br /> IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ REVISIONS <br /> 9 p 211-264 V 183-229 V 211-264 V 183-229 V DESCRIPTION DATE REV <br /> IQ Envoy'", Enphase IQ Battery",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) <br /> Enlighten" Nominal frequency 60 60 <br /> monitoring and analysis software. <br /> Extended frequency range 47-6 -68 Hz 47 8 Hz <br /> IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms <br /> Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) Signature with Seal <br /> standards set forth by previous generations and Overvoltage class AC port III III <br /> undergo over a million hours of power-on testing, AC port backfeed current 0 A o A <br /> enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 <br /> Power factor(adjustable) 0.85leading...0.85lagging 0.85leading...0.85lagging <br /> warranty Of up to 25 years. EFFICIENCY @240 V @208 V @240 V @208 V DATE:08/10/2021 <br /> Peak efficiency 97.6% 97.6% 97.5% 97.3 <br /> CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% PROJECT NAME&ADDRESS <br /> MECHANICAL DATA <br /> Ambient temperature range -400C to+65°C <br /> Relative humidity range 4%to 100%(condensing) <br /> Easy to Install Connector type(IQ7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) <br /> Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) <br /> Lightweight and simple Weight 1.08 kg(2.38lbs) <br /> roved,lighter two-wire cabling O <br /> Faster installation with improved, 9 9 Cooling Natural convection-No fans � O <br /> Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes w O CO <br /> Pollution degree PD3 J w CN O <br /> Enclosure Class II double-insulated,corrosion resistant polymeric enclosure J O z U 0 O O <br /> 06 <br /> Productive and Reliable Environmental category/UV exposure rating NEMA Type 6/outdoor J <br /> w >Q � <br /> Optimized for high powered 60-cell and 72-cell*modules FEATURES LJ J <br /> More than a million hours of testing Communication Power Line Communication(PLC) Q <br /> LO <br /> Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. - Q O <br /> Both options require installation of an Enphase IQ Envoy. z U) J U J O <br /> UL listed w ti <br /> Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break [)� <br /> a disconnect required by NEC 690. U) i0 W <br /> I' Compliance CA Rule 21(UL 1741-SA) <br /> Smart Grid Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, (n W 11 <br /> f ur„ CAN/CSA-C22.2 NO.107.1-01 Q <br /> Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and <br /> ° frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC <br /> Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. <br /> grid requirements <br /> Configurable for varying grid profiles <br /> Meets CA Rule 21(UL 1741-SA) <br /> U�® EQUIPMENT <br /> SHEET NAME T*The IQ 7+Micro is required to support 72-cell modules. EQU I PM EN 1.No enforced DC/AC ratio.See the compatibility calculator at httos://enphase.com/en-us/support/module-compatibility. <br /> 2.Nominal voltage range can be extended beyond nominal if required bythe utility. SPECIFICATION <br /> 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. <br /> EN P HAS E. To learn more about Enphase offerings,visit enphase.com EN P HAS E. SHEET SIZE <br /> To learn more about Enphase offerings,visit enphase.com �/ �./ <br /> ©2019 Enphase Energy.All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. ANSI <br /> I B <br /> 2019-3-26 A J <br /> 11" X 17" <br /> SHEET NUMBER <br /> PV-7 <br />