Data Sheet Enphase IQ Combiner 3
<br /> Enphase Networking
<br /> MODEL NUMBER
<br /> IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy"printed circuit board for integrated revenue grade PV
<br /> X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5%)and optional*consumption monitoring(+/-2.5 i).
<br /> ACCESSORIES and REPLACEMENT PARTS(not included,order separately)
<br /> Enphase Mobile Connect'"
<br /> CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60
<br /> CELLMODEM-01 (3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands,
<br /> CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.)
<br /> Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5i). SYSTEM INFO.
<br /> Enphase The Enphase IQ Combiner 3r with Enphase CT-200-SPLIT (24)HANWHA QCELL
<br /> *Consumption monitoring is required for Enphase Storage Systems (Q.PEAK DUO-G8+340W)
<br /> IQ En voyT" consolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encha rge'"storage and Enphase (24)ENPHASE IQ7-60-2-US(240V)
<br /> Q Combiner 3 COMMS-KIT-01 Enpower"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner"
<br /> equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. DC SYSTEM SIZE:8.16 KWDC
<br /> Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. AC SYSTEM SIZE:6.00 KWAC
<br /> (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,10A,Eaton BR210
<br /> BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 REVISIONS
<br /> providing a consistent, pre-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 DESCRIPTION DATE REV
<br /> EPLC-01 Power line carrier(communication bridge pair),quantity-one pair
<br /> residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01)
<br /> 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3
<br /> ELECTRICAL SPECIFICATIONS Signature with Seal
<br /> busbar assembly. Rating Continuous duty
<br /> System voltage 120/240 VAC,60 Hz
<br /> Eaton BR series busbar rating 125 A
<br /> Max.continuous current rating(output to grid) 65 A
<br /> DATE:08/10/2021
<br /> Max.fuse/circuit rating(output) 90 A
<br /> Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) PROJECT NAME&ADDRESS
<br /> Smart Max.continuous current rating(input from PV) 64 A
<br /> Includes IQ Envoy for communication Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included
<br /> fi{ and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy
<br /> Flexible networking supports Wi-Fi, MECHANICAL DATA
<br /> III 1 Ethernet,or cellular Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). p
<br /> C J Optional AC receptacle available for PLC Weight 7.5 kg(16.51bs) 0
<br /> bridge C:) �
<br /> i Ambient temperature range -400 C to+461 C(-400 to 115*F) J w N 0
<br /> I Provides production metering and optional CO O
<br /> Cooling Natural convection,plus heat shield J 0
<br /> consumption monitoring U
<br /> Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction O z w Q 0
<br /> R W
<br /> Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors lL
<br /> Simple 60 A breaker branch input: 4 to 1/0 AWG copper conductors 0
<br /> Main lug combined output: 10 to 2/0 AWG copper conductors
<br /> Reduced size from previous combiner Neutral and ground: 14 to 1/0 copper conductors Z U) J W~ 0
<br /> Always follow local code requirements for conductor sizing. • •
<br /> Centered mounting brackets support single Altitude To 2000 meters(6,560 feet) U) N w
<br /> stud mounting LL_ � �
<br /> INTERNET CONNECTION OPTIONS Z) > Z
<br /> Supports back and side conduit entry W 0-
<br /> 4 Integrated Wi-Fi 802.11b/g/n (n
<br /> Up to four 2-pole branch circuits for 240 VAC Q
<br /> plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included)
<br /> 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)or CELLMODEM-M1(4G based LTE-M)
<br /> (not included)
<br /> COMPLIANCE
<br /> Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003
<br /> Production metering:ANSI C12.20 accuracy class 0.5(PV production)
<br /> Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1
<br /> 3R enclosure SHEET NAME
<br /> • EQUIPMENT
<br /> Five-year limited warranty
<br /> UL UL listed To learn more about Enphase offerings,visit enphase.com SPECIFICATION
<br /> LISTED ©2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the SHEET SIZE ENPHASE.ENPHASE. trademarks of Enphase Energy,Inc.
<br /> To learn more about Enphase offerings,visit enphase.com V 2019-11-04 v ANSI B
<br /> 11" X 17"
<br /> SHEET NUMBER
<br /> PV-8