My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE 2025-03-24
>
Address Records
>
RUCKER AVE
>
3006
>
3006 RUCKER AVE 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:09:50 AM
Creation date
2/7/2025 9:55:57 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> If mechanically delivered,indicate that <br /> ventilation systems are configured to provide <br /> not more than 150%of,but at least the <br /> minimum required volume of outdoor air to <br /> each zone per IMC,ASHRAE 62.1 or other <br /> applicable code(WAC,OSHA,etc);or <br /> exception applied <br /> NA If delivered via natural ventilation,identify <br /> required elements per IMC including: <br /> minimum openable area to the outdoors or <br /> qualifying adjoining spaces;criteria for <br /> ensuring required ventilation is provided <br /> during all occupied hours of the year <br /> (including during inclement outdoor <br /> conditions) <br /> NA C403.2.2.2 Exhaust Indicate that exhaust systems are configured <br /> to provide not more than 150%of,but at least <br /> the minimum required volume from each <br /> zone per IMC,or other applicable code <br /> (WAC,OSHA,etc);or exception applied <br /> NA C403.4.2.4 Exhaust system off- Refer to Requirements List section HVAC <br /> hour controls Controls for off-hour controls requirements <br /> for exhaust systems <br /> C403.3.6 Balanced ventilation For Group R-2 dwelling and sleeping units, <br /> for Group R-2 indicate that each habitable space is provided <br /> occupancy with a balanced ventilation system;indicate <br /> system is provided with energy recovery with <br /> 60%sensible recovery effectiveness <br /> C403.7.1 Demand controlled Identify spaces>500 sf with occupant load>_ <br /> ventilation 25 people/1,000 sf per IMC;for each space <br /> indicate whether it is served by an HVAC <br /> system with total design ventilation air> <br /> 3,000 cfm,and/or the system has airside <br /> economizer or automatic modulating outdoor <br /> air damper;indicate controls are configured to <br /> provide demand controlled ventilation or <br /> provide supporting documentation for applied <br /> exception <br /> C403.7.2 Occupancy sensors For gyms,classrooms,auditoriums, <br /> conference rooms and other spaces with <br /> occupant load>25 people/1,000 sf per IMC, <br /> that have an area>500 sf,indicate occupancy- <br /> based ventilation air control when space is <br /> unoccupied and method(closes outdoor air <br /> damper or shuts-off equipment);or alternate <br /> means provided to automatically reduce <br /> ventilation air when space is partially <br /> occupied;or exception applied <br /> C403.7.3 Ventilation air For ventilation air systems that operate in <br /> heating control conjunction with heating and cooling systems, <br /> indicate that ventilation air is tempered(via <br /> heating or heat recovery)to no greater than <br /> 60F when the space conditioning system is in <br /> cooling mode <br /> Page 7125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.