My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE 2025-03-24
>
Address Records
>
RUCKER AVE
>
3006
>
3006 RUCKER AVE 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/24/2025 10:09:50 AM
Creation date
2/7/2025 9:55:57 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • i of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.7.4.2 Ventilation controls Refer to Requirements List section HVAC <br /> for Group R-1 Controls for Group R-1 temperature setback <br /> guestrooms and set-up controls <br /> Indicate method of ventilation and exhaust <br /> isolation for each guest room and automatic <br /> controls that are configured to turn off <br /> ventilation and exhaust airflow when each <br /> room is unoccupied <br /> C403.8.4 Group R occupancy Refer to Requirements List section Fans& <br /> exhaust fan efficacy Fan Controls <br /> C403.7.5 Enclosed loading For enclosed loading docks,indicate <br /> C403.7.5.1 dock ventilation ventilation/exhaust system method of <br /> activation(gas detection system for CO and <br /> NO2,or occupancy sensors),and control <br /> method(staged or modulating) <br /> C403.7.5 Enclosed parking For enclosed parking garages,indicate <br /> C403.7.5.2 garage ventilation ventilation/exhaust system activated by gas <br /> detection system for CO and NO2,and <br /> control method(staged or modulating);or <br /> exception applied <br /> C403.7.6 Ventilation/exhaust For systems with design ventilation air> <br /> systems energy 5,000 cfm,or design supply air cfm and% <br /> recovery ventilation air exceeding the values in Tables <br /> C403.7.6(1)or(2),indicate exhaust air energy <br /> recovery method;or exception applied with <br /> supporting calculations <br /> For rooms served by multiple systems with <br /> aggegate design ventilation air>5,000 cfm, <br /> or aggregate design supply air cfm and% <br /> ventilation air exceeding the values in Tables <br /> C403.7.6(1)or(2),indicate exhaust air energy <br /> recovery method;or exception applied with <br /> supporting calculations <br /> Indicate energy recovery rated effectiveness <br /> that increases outdoor air enthalpy by>_50% <br /> based on delta between outdoor air and return <br /> air enthalpies at design conditions <br /> C403.7.7.1.1 Kitchen exhaust hood Indicate on plans the type,duty,UL rating and <br /> C403.7.7.1.2 system exhaust airflow rate of each kitchen hood <br /> C403.7.7.1.3 <br /> Provide calculations that show a balanced <br /> accounting of total kitchen exhaust(include <br /> all hoods)with%of:supply air,transfer air <br /> from adjacent spaces,and make-up air <br /> For hoods with make-up air drawn directly <br /> into the exhaust air cavity of each hood, <br /> indicate that replacement air does not exceed <br /> 10%of hood exhaust airflow rate <br /> For kitchens with total hood exhaust <br /> exceeding 2,000 cfm,indicate that each hood <br /> is UL 710 rated and maximum exhaust <br /> airflow rate of each hood is per Table <br /> C403.7.7.1.2;or exception applied <br /> Page 8125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.