PROJECT NOTES <br />ELECTRICAL LEGEND <br />1. GENERAL: WORK SHALL BE DONE IN ACCORDANCE WITH CODES <br />AS ADOPTED BY THE CITY OF EVERETT, SNOHOMISH COUNTY, <br />AND THE STATE OF WASHINGTON. <br />2. LOCATIONS OF ELECTRICAL DEVICES, LIGHTING FIXTURES, ETC., <br />INDICATED ON CIVIL / STRUCTURAL PLANS - INCLUDING <br />SECTIONS, ELEVATIONS, NOTES, OR OTHER INDICATORS - TAKE <br />PRECEDENCE OVER LOCATIONS SHOWN ON ELECTRICAL <br />DRAWINGS. <br />3. REFER TO CIVIL, STRUCTURAL, MECHANICAL, ETC., DRAWINGS <br />FOR WORK IN OTHER DIVISIONS. INFORMATION CONVEYED <br />WITHIN THE ELECTRICAL DRAWINGS ILLUSTRATING OR <br />REFERENCING WORK OF OTHER DIVISIONS IS FOR REFERENCE <br />ONLY. SPECIFICATION BYTHE APPROPRIATE DIVISIONS SHALL <br />APPLY. <br />4. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO <br />SPECIFIC NOTE; HOWEVER, GENERAL NOTES ON EACH SHEET <br />SHALL APPLY IN PRACTICE TO ALL ELECTRICAL DRAWINGS. <br />5. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE <br />SHOWN (FOR SIMPLICITY). PROVIDE MATERIALS AND LABOR <br />NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. <br />6. STAINLESS STEEL HARDWARE: MATERIALS USED FOR THE <br />MOUNTING AND SUPPORT OF BOXES CABLES, RACEWAYS, LIGHT <br />FIXTURES, OUTLETS, AND OTHER ELECTRICAL EQUIPMENT, SHALL <br />BE 316 STAINLESS STEEL. THIS REQUIREMENT APPLIES TO THE <br />AFOREMENTIONED COMPONENTS WHEN INSTALLED OUTSIDE <br />ABOVE GRADE OR WHEN INSTALLED OVER WATER (APPROACH <br />PIER, PIER, & FLOATING DOCKS). <br />7. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. EXACT LOCATIONS <br />OF ELECTRICAL EQUIPMENT ARE APPROXIMATE. CHANGES MADE <br />BY THE OWNER IN LOCATING ELECTRCAL COMPONENTS OF UP <br />TO TEN FEET HORIZONTALLY IS A PART OF THIS CONTRACT FOR <br />FLOATS. THESE CHANGES MAY BE IMPLEMENTED, AT NO CHARGE <br />TO THE OWNER, UNTIL FINAL APPROVAL OF SHOP DRAWINGS. <br />8. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION <br />CHASES AND CONDUITS WITH OTHER TRADES. ADJUST <br />LOCATIONS AS NECESSARY TO AVIOD CONFLICTS. <br />A,AMP AMPERES EF <br />AF AMPERE RATED FUSES EMT <br />(RATED) <br />Lv AFF ABOVE FINISHEDFLOOR ENCL <br />AEG ABOVE <br />LUMINUM(ALLO GRADE FOIL <br />AL ALUMINUM (ALLOY) EPA <br />o ALC AUTOMATEDLIGHTING <br />SWITCH <br />CONTROL EWC <br />� AS AMPERE (RATED)SWITCH EWH <br />ATS AUTOMATIC TRANSFER SWTCH FA <br />AUTO AUTOMATIC FAA <br />AUX AUXILIARY FC <br />AWG AMERICAN WIREGAUGE FL <br />BAT BATTERY FLEX <br />o BFG BELOW FINISIT ED GRADE FU <br />C CONDUIT (CIRCULAR RACEWAY) GEN <br />o CAB CABINET PC <br />CB CIRCUIT BREAKER <br />CFM CUBIC FEET PER MINUTE AND <br />U GOT CIRCUIT ABC <br />w CLG CEILING GRID <br />CO CONDUIT ONLY HP <br />d CT CURRENT TRANSFORMER HE <br />CU COPPER AS <br />r` DC DIRECT CURRENT ID <br />DISC DISCONNECT IG <br />CD DIA DIAMETER IN <br />cs <br />w N DIV DIVISION ISO <br />/ DP DISTRIBUTION PANEL K <br />T% DPDT DOUBLE POLE DOUBLETHROW KCM <br />o r DPST DOUBLE POLE SINGLETHROW KO <br />DWG DRAWING KW <br />Eor(E) EXISTING LOA <br />� t4 <br />AS&::�BOR POWER <br />E E R 5, IN(. <br />E <br />I PM: ED DAVID, PE TEL: 205.855.4600 <br />0 U U <br />Co <br />J <br />/ <br />�o <br />Port of <br />00 <br />"' <br />W, <br />EVERETT <br />O Y <br />N <br />P.O. BOX 538 <br />EVERETT, WA 98205 <br />o / (425) 259-3164 <br />2 U <br />9. SCOPE OF WORK: THE SCOPE OF ELECTRICAL WORK FOR THIS <br />PROJECT INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING: <br />A. FURNISH AND INSTALL POWER, LIGHTING, AND <br />COMMUNICATIONS, SYSTEMS FOR FUEL DOCK, INCLUDING <br />SHORE POWER PEDESTALS. SCOPE INCLUDES THE <br />INSTALLATION AND CONNECTION OF SHORE POWER PEDESTALS <br />ON EXISTING FUEL DOCK (EXISTING FUEL DOCK DISPENSING <br />SYSTEM TO BE REMOVED). PROVIDE COMMUNICATIONS WIRING <br />AS SPECIFIED, INCLUDING RACEWAYS FROM DATA OUTLETS TO <br />DATA J-BOXES OR RACKS. CONNECT THE FOLLOWING SYSTEMS <br />PER DRAWINGS OR MANUFACTURERS REQUIREMENTS: <br />A.A. FUEL SYSTEM CONTROLS; INTERCONNECT DISPENSING <br />CONTROL SYSTEM TO (E) UPLAND FUEL PUMP CONTROL <br />PANEL. <br />A.B. LEAK DETECTION SYSTEM <br />A.C. POINT OF SALE (POS) SYSTEM <br />A.D. FIRE ALARM SYSTEM WITH RADIO TRANSPONDER. <br />A. E. LIGHTING CONTROL SYSTEM WITH HUBBELL WISCAPE. <br />A.F. SECURITY SYSTEM CABLING (EQUIPMENT BY OTHERS). <br />A.G. PORT NETWORKWIRING, INCLUDING FIBER OPTIC <br />CABLING AND CATEGORY WIRE. PROVIDE WALL <br />MOUNTED DATA RACK AND 5-FOOT PLUG -STRIP. <br />A.H. EPO SYSTEM WIRING; CONNECT TO (E) UPLAND EPO. <br />B. PERMITS: GIVE ALL NECESSARY NOTICES, OBTAIN ALL PERMITS <br />AND PAY ALL GOVERNMENT TAXES, FEES AND OTHER COSTS IN <br />CONNECTION WITH THIS WORK. OBTAIN ALL REQUIRED <br />CERTIFICATES OF INSPECTION OF THE WORK AND DELIVER <br />SAME TO THE ENGINEER AT THE TIME OF SUBSTANTIAL <br />COMPLETION AND BEFORE REQUEST FOR FINAL PAYMENT. <br />C. PHASING: PHASED INSTALLATION OF THE ELECTRICAL SERVICE <br />EQUIPMENT IS REQUIRED. ELECTRICAL OUTAGES REQUIRED <br />FOR THE EXECUTION OF THIS WORK SHALL BE LIMITED TO (2) <br />8-HOUR PERIODS DURING DAYLIGHT HOURS. SCHEDULE <br />OUTAGES WITH OWNER A MINIMUM OF 72 HOURS IN ADVANCE. <br />PROVIDE CODE COMPLIANT TEMPORARY CONNECTIONS AND <br />SERVICES AS NEEDED FOR CONSTRUCTION; INCLUDING <br />SERVICES TO PORTABLE TRAILERS, POWER TOOLS, AND OTHER <br />EQUIPMENT, USED FOR CONSTRUCTION. <br />D. DEMOLITION: SEE OTHER DIVISIONS FOR SCOPE OF DEMOLITION <br />WORK. REMOVE ELECTRICAL AND COMMUNICATIONS SYSTEMS <br />THAT EXIST IN DEMOLISHED AREAS. MAKE SYSTEMS SAFE, SEAL <br />OPENINGS, AND UPDATED SIGNAGE/SCHEDULES. FINAL <br />CONFIGURATION SHALL COMPLY WITH CURRENT CODE. <br />E. COORDINATION WITH FLOAT FABRICATOR: THE CONTRACTOR <br />SHALL COORDINATE ELECTRICAL, EQUIPMENT, CHASE, AND <br />JUNCTION BOX LOCATIONS WITH THE FLOAT MANUFACTURER. <br />VERIFY PROVISIONS FOR EQUIPMENT ANCHORING, AND THAT <br />CHASES AND JUNCTION BOX SIZES/LOCATIONS ARE SUITABLE <br />FOR THE INSTALLATION OF SPECIFIED ELECTRICAL SYSTEM <br />COMPONENTS USING THE MEANS/METHODS PLANNED FOR <br />INSTALLATION. FLOAT SHOP DRAWINGS WILL NOT BE APPROVED <br />WITHOUT WRITTEN VERIFICATION THAT THE AFOREMENTIONED <br />COORDINATION HAS TAKEN PLACE AND THAT THE FLOAT SHOP <br />DRAWINGS HAVE BEEN APPROVED BYTHE ELECTRICAL SYSTEM <br />INSTALLER. IMPORTANT: COORDINATE CHASE ALIGNMENT IN <br />NEW FLOATS WITH EXISTING CHASES. <br />ABBREVIATIONS <br />EXHAUST FAN <br />LOP <br />LIGHT CONTROL PANEL <br />PRI <br />PRIMARY <br />ELECTRI CAL METALLIC TUBI NG <br />MAX <br />MAXIMUM <br />PSE <br />PUGET POWER ENERGY <br />ENCLOSURE <br />MCA <br />MI NIMUM CI ROUT AMPERES <br />REQD <br />REQUIRED <br />END OF LINE <br />HER <br />MANUFACTURER <br />RNC <br />RIGID NONMETALLIC CONDUIT (PVC) <br />EFFECTIVE PROJECTED AREA <br />MIN <br />MINIMUM <br />PS <br />RAPID START <br />ELECTRIC WATER COOLER <br />MISC <br />MISCELLANEOUS <br />SEC <br />SECONDARY <br />ELECTRICWATER HEATER <br />MLO <br />MAIN LUGS ONLY <br />SLWD <br />SINGLE LINE WRING DIAGRAM <br />FIRE ALARM <br />AND <br />MOUNTED <br />SPOT <br />SINGLE POLE DOUBLE THROW <br />FIRE ALARM ANNUNIATOR <br />MTR <br />MOTOR <br />SPST <br />SINGLE POLE SINGLE THROW <br />FOOT CANDLES <br />-N <br />NEUTRAL (GROUNDED CONDUCTOR) <br />SURF <br />SURFACE <br />FULL LOAD AMPERES <br />NC <br />NORMALLY COSED <br />SAVED <br />SWITCHBOARD <br />FLEXIBLE <br />NEC <br />NATIONAL ELECTRICAL CODE <br />SWGR <br />S ITU GEAR <br />FUSE <br />-,LED <br />NEGATIVE <br />TB <br />TERMINAL BOARD <br />GENERATOR <br />NEAR, <br />NATIONAL ELECTRICAL <br />TDC <br />TIME DELAY CLOSING <br />GROUND FAULT CIRCUIT <br />MANUFACTURE'S ASSOC <br />TOO <br />TIME DELAY OPENING <br />INTERRUPTER <br />NL <br />NIGHT LIGHT(UNSWITCHED) <br />TEL <br />TELEPHONE <br />GROUND <br />NO <br />NORMALLY OPEN <br />TOP <br />TYPICAL <br />GALVANIZED RIGID STEEL CONDUIT <br />NTS <br />NOT TOSCALE <br />UL <br />UNDERWRITERS LAB <br />OC <br />ON CENTER <br />LION <br />UNLESS OTHEPWSE NOTED <br />IN <br />H <br />HORSEPOWER <br />HORSEPOWER <br />OUTSIDE <br />UPS <br />UNINTERRUPTIBLE POWER SUPPLY <br />HERTZ (CYCLES PER SECOND) <br />OFDCI <br />OWNER FUDRNISIIED CONTRACTOR <br />V <br />VOLTS <br />ILLUMINATING ENGINEERING SOCIETY <br />INSTALLED <br />VA <br />VOLT-AMPERES <br />I US DE DIAMETER <br />OFOI <br />OWNER FURNISHED, OWNER <br />VFD <br />VARIABLE FREQUENCY DRIVE <br />W <br />WATT <br />ISOLATED GROUND <br />INSTALLED <br />INCANDESCENT <br />OS <br />OCCUPANCY SENSOR <br />W/ <br />WITH <br />W/0 <br />WITHOUT <br />INTERMEDIATE METAL CONDUIT <br />P <br />POLE <br />KEY OPERATED <br />PB <br />PUSH-BUTTON <br />PAR <br />WEATHERPROOF <br />THOUSAND CIRCULAR MILS <br />PEND <br />PENDANT <br />ROMR <br />TRANSFORMER <br />KNOCKOUT <br />PH <br />PHASE <br />IN <br />INCHES <br />KILOWATTS <br />PNL <br />PANEL <br />',FT <br />FEET <br />KILOVOLT -AMPERES <br />+EPOS <br />POSITIVE <br />- <br />PHASE <br />1Tff0 05/19/2023 EJD ISSUED FOR BID <br />1601 5th Avenue, Suite 1300 <br />Seattle, Washington 98101 0 04/11 /2023 EJD ISSUED FOR PERMIT REVIEW <br />(206) 382-0600 Fax (206) 382-0500 <br />PROJECT NO. 1600120 No. DATE BY REVISION <br />FIRE ALARM SYSTEM <br />SYMBOL <br />DESCRIPTION <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FMB 1 <br />FI RE ALARM REMOTE AN NUN CI ATOP <br />❑F <br />FIRE ALARM SYSTEM MANUAL PULL STATION, WALL <br />MOUNTED <br />SPEAKER- CEILING, WALL MOUNTED <br />ED <br />STROBE, WALL MOUNTED (X=CANDELA RATING) <br />x <br />m4 <br />COMBINATION SPEAKERSTROBE, WALL MOUNTED <br />X <br />(X- CANDELA RATING) <br />SPRINKLER VALVE TAMPER SWITCH LOCATION <br />SPRINKLER FLOW SWITCH CONNECTION <br />51 <br />SMOKE DETECTOR CEILING OR PLENUM MOUNTED. <br />PHOTOELECTRIC TYPE LION <br />OC <br />SMOKE SENSOR DUCT MOUNTED, WITH SAMPLING TUBES. <br />PHOTOELECTRIC TYPE LION <br />Q <br />ELECTROMAGNETIC DOOR HOLDER, WALL MOUNTED <br />® <br />FIREMAN PHONE JACK, WALL MOUNTED <br />m <br />FIREMAN PHONE HAND SET, WALL MOUNTED <br />FIRE ALARM CONNECTION TO COMBINATION EIRE/SMOKE <br />® <br />DAMPER <br />® <br />FLAME DETECTOR (FLICKER DETECTOR) <br />❑ <br />LIGHT (LIGHT SIGNAL LIGHT, INDICATOR LAMP, STROBE) <br />HEAT DETECTOR CEILING MOUNTED. RATE OF RISE AND <br />FIXED TEMPERATURE TYPE, DUN <br />QF <br />HEATDETECTOR-FIXEDTEMP. ONLY <br />% <br />HEATDETECTOR-RATEOFRISEONLY <br />pry <br />POST INDICATOR VALVE (PIV) CONNECTION <br />SIGNAL DEVICES <br />SYMBOL <br />DESCRIPTION <br />EQUIPMENT TERMINAL BOARD 8HIGH X W IDTH AS SHOWN, <br />FIRE TREATED. <br />® <br />COMBO TELEPHONE/DATA OUTLETWALL <br />V <br />TELEPHONEOUTLET-WALL <br />V <br />DATA OUTLET - WALL <br />OS <br />SPEAKER WALL CEILING <br />VOLUMECONTROL-WALL <br />BELL <br />^LY <br />�y <br />BUZZER <br />q3:r <br />CHIME <br />© C� <br />SYSTEM CLOCK WALL CEILING <br />® <br />EMERGENCY CALL BOX <br />® <br />LEAK DETECTOR <br />SECURITY SYSTEM <br />DESCRIPTION <br />iSYM�BOL� <br />i w" Iv <br />(LTV SECURITY CAMERA <br />�p <br />DOOR POSITION MONITORSWTCH <br />INFRARED REQUEST TO EXIT DEVICE-WALLICEILING <br />MOUNTED <br />INTERCOMSTATION- WALL, DESKMOUNTED, <br />M <br />M = MASTER STATION <br />❑ <br />PUSH BUTTON STATION <br />® <br />CARDREADER-WALLMOUNTED <br />ELECTRIC LOCK <br />OS <br />ELECTRIC STRIKE <br />® <br />MAGNETIC LOCK <br />© <br />ELECTRIC POWER TRANSFER HINGE <br />NO. I DATE I BY I REVISION <br />LIGHTING <br />SYMBOL <br />DESCRIPTION <br />FLUORESCENT RECESSED LUMINAIRE <br />(REFER TO LUMINAIRE SCHEDULE FOR TYPE) <br />FLUORESCENT SURFACE- MOUNTED LUMINAIRE <br />(REFER TO LUMINAIRE SCHEDULE) <br />SITAN NG OF ANY LUMINAIRE INDICATES CONNECTION <br />® <br />TO EMERGENCY CIRCUIT. <br />O g <br />HID FIXTURE <br />Q <br />DOWNLIGHT- SURFACE, RECESSEDCEIUNG MOUNT <br />® <br />FLOOR OR GRADE MOUNTED FIXTURE <br />0 <br />WALLWASHSURFACE, RECESSED CEILING MOUNT <br />�S <br />TRACK LIGHTING WITH HEALS AS INDICATED. <br />FLUORESCENT STRIPLIGHT- POWER FEED SECTION, <br />FEED THOUGH SECTION, LENGTH AS SHOWN. <br />FLUORESCENT WALL BRACKET-RESTROOM <br />DIRECTIONAL HID FIXTURE <br />In <br />ADA APPROVED WALL SCONCE <br />® <br />ILLUMINATED EXIT SIGN, SHADEDQUADRANT <br />INDICATESFACES, ARROWASSHOVNV <br />0-0 <br />POLE MOUNTED LUMINAIRE <br />4 <br />FOOT" INDICATES WALL MOUNTED LUMINAIRE <br />>:NX <br />FIXTURE TYPE IDENTIFICATION DESIGNATION <br />GGO <br />BATTERY POWER EMERGENCY UNIT EQUIPMENT (SEE <br />SCHEDULE FOR QUANTITY OF HEADS) WALL <br />CEILING MOUNTED. <br />d <br />REMOTEHEAD <br />OPTICAL SENSOR AND REFLECTOR <br />SWITCHING CONTROLS <br />SYMBOL <br />DESCRIPTION <br />SINGLE POLE SWTCH (SUPERSCRIPT DENOTES SIMILARLY <br />a <br />MARKED LUMINARIES CONTROLLED TOGETHER) <br />TWO POLE SWTCH <br />THREE WAY SWITCH <br />+ <br />FOUR WAY SWITCH <br />KEY OPERATED SWITCH <br />r'hP <br />DIMMER SWITCH. NUMBER INDICATES WATTAGE RATING. IF <br />NOT SHOWN 800W MINIMUM. <br />W <br />SWITCH WITH PILOT (PILOT IS ON WHEN SWITCH IS "ON") <br />R <br />SCOTCH WITH PILOT (PILOT Is ON WHEN SWITCH Is °oEP') <br />$T <br />TIMER SWITCH <br />WEATHERPROOF SCOTCH <br />d M <br />MOTOR RATED TOGGLE WJTHERMAL <br />P <br />OVERLOAD PROTECTION <br />® <br />PHOTOCELL <br />0 <br />TIME CLOCK <br />1-1 <br />WALL MOUNTED DUAL LEVEL SWITCHING OCCUPANCY <br />nw� <br />SENSOR <br />S <br />EMERGENCY POWER OFF HEAVY-DUTY OIL TIGHT RED <br />MUSHROOM HEAD PUSH-BUTTON <br />® <br />LIGHTING CONTROL PANEL <br />LIGHTING CONTROL STATION <br />DISTRIBUTION & EQUIPMENT <br />SYMBOL <br />DESCRIPTION <br />BRANCH CIRCUIT PANELBOARDS, SURFACE AND RECESS <br />® <br />MOUNTED <br />SOLID=129208V <br />HATCHED 277/480V <br />TRANSFORMER <br />T <br />SERVICE AND/OR DISTRIBUTION EQUIPMENT <br />MOTOR CONNECTION .X= HORSEPOWER (WHERE SHOWN) <br />® <br />CONNECTI ON TO DIV. 15 FURNISHED VARIABLE FREQUENCY <br />® <br />DRIVE WITH INTEGRAL DISCONNECT DIV. 16TOINSTALL <br />VFD EST PMENT <br />DISCONNECTSWITCH SIZE AS NOTEDOR IF NOT SHOWN <br />SIZE PER CONNECTED MOTOR SIZE (ARCH -BY DIVISION 15, TYR). <br />�jp� <br />FUSED DISCONNECT SWITCH SIZE AS NOTED OR IF NOT SHOWN <br />SIZE PER CONNECTED MOTOR SIZE (ARCH '-BY DIVISION 15, TYR). <br />DISCONNECT W/ MAGNETIC MOTOR STARTER (CONTROLLER)OR <br />]OG <br />CONTACTOR. AREAS NOTED OR IF NOT SHOWN SIZE PER <br />CONNECTED MOTOR SIZE ('MECH'=BY DIVISION 15, TOP). <br />MAGNETIC MOTOR STARTER (CONTROLLER) OR CONTACTOR <br />® <br />ORNOT SHOWNCONNECTED <br />MOTORSIZENOTED <br />15 LLD <br />05/19/2023 <br />POWER DEVICES <br />SYMBOL <br />DESCRIPTION <br />O_ q. [t�] <br />SIMPLEX RECEPTACLE- WALL, CEILING, FLOOR <br />C � <br />DUPLEXRECEPTACLE- WALL, CEILING, FLOOR <br />(OF 11011c 10 <br />DOUBLE DUPLEX RECEPTACLE WALL CLG, FLOOR <br />DUPLEX RECEPTACLE AT SPECIAL HEIGHT <br />+44 <br />DOUBLE DUPLEX RECEPTACLE AT SPECIAL HEIGHT <br />DUPLEXRECEPTACLE-WALL -DEDICATED <br />OR <br />DUPLEXRECEPTACLE- WALL -HALFSWITCHED <br />CE <br />DUPLEX RECEPTACLE- WALL- ABOVE COUNTER/ <br />BACKSPLASH SEE ARCHITECTURAL DRAWINGS. <br />C <br />DUPLEXRECEPTACLE-WALL- WTH INTEGRAL GROUND <br />�'131 <br />FAULT CIRCUIT INTERRUPTER <br />06 <br />DUPLEX RECEPTACLE W/WEATHERPROOF COVER <br />® ®C <br />SPECIAL PURPOSE RECEPTACLE WALL CEILING <br />NEAR, CONFIGURATION AS NOTED <br />® <br />ELECTRICAL EQUIPMENT CONNECTION <br />PROVIDE#10 AWG NEUTRALS. USELIQHDDTIGHTFLEX. <br />FLUSH FLOOR BOX DEVICE-DEVICETYPESPER <br />®77 <br />SYMBOLS SHOWN. <br />PEDESTAL FLOOR DEVICE-DEVICETYPESPER <br />®� <br />SYMBOLS SHOWN. <br />TWO-PIECE SURFACE METAL RACEWAY WITH RECEPTACLE <br />AS NOTED, LENGTH AS INDICATED ON THE DRAWINGS <br />AND WITH ALL FITTINGS AS REQUIRED <br />TELE/POWER POLE, POWER POLE <br />COURTEST PHONE WITH ENCLOSURE <br />TWO-PIECE SURFACE METAL RACEWAY WITH RECEPTACLE <br />AT6" O.C(LENGTH AS INDICATED). <br />X FyI <br />POWER PEDESTAL <br />X = 30 = 30A,120V OUTLET <br />X = 50 = 50A,120/240V OUTLET <br />X = 20GFCI = 20g120V DUPLEX GFCI PROTECTED OUTLET <br />Y=DOCK OR ROW ID# <br />Z = SLIP NUMBER/STALL(S) - (1)POWER HEAD EA <br />NOTE. X' DESIGNATES OUTLET PER SLIP. MULTIPLE REFERENCES <br />(30150) INDICATES MULTIPLE OUTLETS PER SLIP. <br />DIAGRAMS <br />SYMBOL <br />DESCRIPTION <br />OFF <br />IYY <br />HAND/OFF/AUTO SWTCH <br />SWTCH <br />OVERLOADS <br />NORMALLY CLOSED CONTACTOR OR RELAY CONTACTS <br />j^ <br />NORMALLY OPEN CONTACTOR OR RELAY CONTACTS <br />BUS DUCT <br />BUS BAR <br />BATTERY (GENERAL) <br />CONNECTOR, FEMALE AND MALE RESPECTIVELY <br />© <br />CONTACTOR COIL <br />RELAY COIL <br />® <br />TRANSIENT VOLTAGE SURGESUPPRESSED <br />CURRENTTRANSFORMER <br />POTENTIAL TRANSFORMER <br />NORMALLY OPEN PUSH BUTTON <br />NORMALLY CLOSED PUSH BUTTON <br />® <br />METER POWER FACTOR <br />® <br />METER KILOWATT HOUR <br />METER COMBINATION KILOWATT HOURKVAR METER <br />UTILITY CO. APPROVED SOCKET WITH METER INSTALLED <br />DELTA CONNECTION <br />GROUND WVECONNECTOR <br />II <br />CONNECTION TO GROUND <br />(.�XXX/Y <br />CIRCUIT BREAKER <br />FOX =AMPACITY Y=POLES <br />FUSED SWITCH, WITH FUSE AND SWTCH AMPERE RATING <br />CIRCUIT BREAKER, MEDIUM VOLTAGE, DRAWOUT <br />�E �N <br />DRAWOUT CI RCUT BREAKER <br />® <br />GROUND FAULT TRIP UNIT <br />KEY INTERLOCK <br />CAPACITOR, POWER FACTOR CORRECTION, SIZEINKVAR <br />YG <br />MOTORGENERATOR <br />SOLENOID <br />WIRING <br />SYMBOL <br />DESCRIPTION <br />CONDUIT CONCEALED IN CEILING OR WALL. LINE WEIGHT <br />TOP TO BOTTOM = NEW, EXISTI NG TO REMAIN. <br />CONDUIT CONCEALED IN OR BELOW CONCRETE UNDER GRADE <br />UNDERFED IN CEILING SPACE OF FLOOR BELOW. LINE WEIGHT <br />TOP TO BOTTOM- NEW, EXISTING TO REMAIN. <br />--- <br />CONDUITEXPOSED. LINE WEIGHT TOP TO BOTTOM- NEW <br />- <br />EXISTINGTOREMAIN. <br />EA STING CONDUIT& WIRING TO BE REMOVED <br />—C— <br />COMMUNICATION CONDUIT/CABLE <br />—MY— <br />MEDIUM VOLTAGE CONDUIT <br />—LV— <br />LOW VOLTAGE CONDUCTORS <br />—C— <br />GROUNDING GRID OR CONDUCTORS <br />—TV— <br />CABLE TV WIRE/CONDUIT <br />—C/H— <br />AERIAL CONDUCTOR(S)/OVERHEAD LINE <br />STROKES INDICATE QUANTITY OF#12 AWG. CONDUCTORS, <br />LION. NOTE NOT ALL WIRING IS SHOWN ON DRAWNG. <br />CONTRACTOR SHALL SCHEDULE OR STANDARD WIRING <br />PRACTICES FOR BRANCH CIRCUITS. <br />GROUND <br />HOT <br />GROUND, ISOLATED <br />NEUTRAL <br />HOME RUN TO INDICATED DESTINATION, 3/4"C MIN. LION <br />CONDUIT RUN TURNED UP THROUGH FLOOROR CEILING. <br />CORE AS REQUIRED. <br />CONDUIT STUBBED OUT AT LOCATION SHOWN PROVIDED <br />INSULATED BUSHING & PULLROPE. <br />TELEPHONE/DATA SLEEVE THROUGH WALL, ABOVE <br />CEILING EXTENDTO ACCESSIBLE LOCATION BOTH SIDES. <br />[� <br />TERMINATE WITH BUSHINGS. (1) 11/4" CO LION. COORDINATE <br />LOCATIONS WITH CABLE INSTALLER(A PRIOR TO <br />ROUGHIN <br />CABLETRAY <br />®C [a <br />JUNCTION BOXES WALL CEILING AND FLUSH FLOOR <br />MOUNTED. 4" SQ. BOX, LION. <br />® <br />PULL BOX MIN. SIZE PER NEC., LION. <br />FLEXIBLE CONDUIT CONNECTION <br />GROUND ROD CONNECTION <br />OGROUND <br />ROD CONNECTION WITH TESTWELL BOX <br />+ <br />LIGHTNING SYSTEM AIR TERMINAL <br />UNDERGROUND PULLBOX/VAULT (P-POWER T=TEL/COM U=UTILITY) <br />® <br />UNDERGROUND PULLBOX/VAULT(PLASTIC) <br />HANDHOLE <br />REFERENCE SYMBOLS <br />SYMBOL <br />DESCRIPTION <br />SHEET NOTE REFERENCE (FLAG NOTES) <br />XXXX <br />FEEDER NOMINAL AMPACITO& TYPE. SEE FEEDER <br />SCHEDULE <br />TOFETAIT TEDNOT ALL <br />REFER TODERENCES. <br />R SHOWN <br />REFERENCES AL DETAIDLS APPLY <br />DETAI ALLD <br />V-V <br />TO ALL APPLICABLE SITUATIONS, U ON. <br />X <br />ELEVATION/PHOTOTAG. REFERTONUMBER <br />V-V <br />AND SHEET INDICATED <br />SECTION TAG'. REFER TO DETAIL NO. ON DRAWING. <br />NOT ALL DETAIL REFERENCES ARE SHOWN. ALL <br />V-V <br />DETAI ITS APPLY. <br />PROJECT ENGINEER: SCALE <br />E. DAVID None : PORT OF EVERETT <br />DE. DAVID 05/19/2023 CENTRAL MARINA FUEL DOCK <br />DRAWN BY: CHECKED BY: <br />K. DAVID E. DAVID <br />APPROVED BY: NOTES, LEGEND, ABBREVIATIONS, <br />& LUMINAIRE SCHEDULE <br />IF SHEET IS LESS THAN 2204 <br />REDUCE SCALE ACCORDINGLY <br />DWG. NO. E0.0 <br />CIE No. H <br />2-0-073-01 L/U� <br />PROJECT V, <br />No, MR—CM-2023-01 MQ <br />SHEET No. 61 OF 88 W <br />