PROJECT NOTES F ELECTRICAL LEGEND
<br /> 1. GENERAL:WORK SHALL BE DONE IN ACCORDANCE WITH CODES 9. SCOPE OF WORK:THE SCOPE OF ELECTRICAL WORK FOR THIS FIRE ALARM SYSTEM LIGHTING POWER DEVICES WIRING
<br /> AS ADOPTED BY THE CITY OF EVERETT,SNOHOMISH COUNTY, PROJECT INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING:
<br /> AND THE STATE OF WASHINGTON. SYMBOL DESCRIPTION SYMBOL DESCRIPTION IYM60L DESCRIPTION SYMBOL DESCRIPTION
<br /> A. X. FII FIRE ALARM CONTROL PANEL FLUORESCENT RECESSEDLUMINAIRE CF&� SIMPLEXRECEPTACLE-WALL,CEILING,FLOOR CONDUIT CONCEALED IN CEILING OR WALL.LINEWEIGHT
<br /> 2. LOCATIONS OF ELECTRICAL DEVICES,LIGHTING FIXTURES,ETC., (REFER TO LUMINAIRE SCHEDULE FOR TYPE) TOP TO BOTTOM=NEW,EXISTING TO REMAIN.
<br /> INDICATED ON CIVIL/STRUCTURAL PLANS-INCLUDING B. PERMITS:GIVE ALL NECESSARY NOTICES,OBTAIN ALL PERMITS IIA FIRE ALARM REMOTE ANNUNCIATOR FLUORESCENT SURFACE-MOUNTED LUMINAIRE �Q� DUPLE%RECEPTACLE-WALL,CEILING,FLOOR
<br /> SECT IDNS,ELEVATIONS,NOTES,OR OTHER INDICATORS-TAKE AND PAY ALL GOVERNMENT TAXES,FEES AND OTHER COSTS IN FIRE ALARM SYSTEM MANUAL PULL STATION,WALL (REFER TO LUMINAIRE SCHEDULE) DYY� __— CONDUIT CONCEALED IN OR BELOW CONCRETE UNDER GRADE
<br /> MOUNTED H Ik a DOUBLE DUPLEX RECEPTACLE-WALL,CLG,FLOOR UNDER PIER,IN CEILING SPACE OF FLOOR BELOW.LINE WEIGHT
<br /> PRECEDENCE OVER LOCATIONS SHOWN ON ELECTRICAL CONNECTION WITH THIS WORK.OBTAIN ALL REQUIRED x C TOP TO BOTTOM=NEW,EXISTING TO REMAIN.
<br /> DRAWINGS. CERTIFICATES OF INSPECTION OF THE WORK AND DELIVER ® SPEAKER-CEILING,WALL MOUNTED ® SHADING OF ANY LUMINAIRE INDICATES CONNECTION 01µ DUPLEX RECEPTACLE AT SPECIAL HEIGHT
<br /> STROBE,WALL MOUNTED(X=CANDELA RATING)
<br /> SAME TO THE ENGINEER AT THE TIME OF SUBSTANTIAL • TO EMERGENCY CIRCUIT. DOUBLE DUPLEX RECEPTACLE AT SPECIAL HEIGHT ___ CONDUIT EXPOSED.LINE WEIGHT TOP TO BOTTOM=NEW,
<br /> H
<br /> 3. REFER TO CIVIL,STRUCTURAL,MECHANICAL,ETC.,DRAWINGS COMPLETION AND BEFORE REQUEST FOR FINAL PAYMENT. x EXISTING TO REMAIN.
<br /> FOR WORK IN OTHER DIVISIONS. INFORMATION CONVEYED F COMBINATION SPEAKERISTROBE,WALL MOUNTED 0 12 HID FIXTURE
<br /> %///f//,
<br /> WITHIN THE ELECTRICAL DRAWINGS ILLUSTRATING OR C. PHASING:PHASED INSTALLATION OF THE ELECTRICAL SERVICE X (X=CANDELA RATING) p DOWNLIGHT-SURFACE,RECESSED CEILING MOUNT DUPLEX RECEPTACLE-WALL-DEDICATED EXISTING CONDUIT&WIRING TO BE REMOVED
<br /> REFERENCING WORK OF OTHER DIVISIONS IS FOR REFERENCE EQUIPMENT IS REQUIRED. ELECTRICAL OUTAGES REQUIRED DUPLEX RECEPTACLE-WALL-HALF SWITCHED —C— COMMUNICATION CONDUIT/CABLE
<br /> ONLY.SPECIFICATION BY THE APPROPRIATE DIVISIONS SHALL FOR THE EXECUTION OF THIS WORK SHALL BE LIMITED TO(2) O SPRINKLER VALVE TAMPER SWITCH LOCATION ® FLOOR OR GRADE MOUNTED FIXTURE
<br /> DUPLE%RECEPTACLE-WALL-ABOVE COUNTER/ —NV— MEDIUM VOLTAGE CONDUIT
<br /> APPLY. 8-HOUR PERIODS DURING DAYLIGHT HOURS.SCHEDULE O SPRINKLER FLOW SWITCH CONNECTION 0 BACKSPLASH.SEE ARCHITECTURAL DRAWINGS.
<br /> WALL WASH-SURFACE,RECESSED CEILING MOUNT
<br /> OUTAGES WITH OWNER A MINIMUM 72 HOURS IN ADVANCE. SMOKE DETECTOR,CEILING OR PLENUM MOUNTED. —LV— LOW VOLTAGE CONDUCTORS
<br /> 4. GENERAL NOTES ARE SHOWN ON SHEETS MOST RELEVANT TO PROVIDE CODE COMPLIANT TEMPORARY CONNECTIONS AND 0 PHOTOELECTRIC TYPE UON N )< TRACK LIGHTING WITH HEADS AS INDICATED. DUPLEX RECEPTACLE-WALL-WITH INTEGRAL GROUND —G— GROUNDING GRID OR CONDUCTORS
<br /> SPECIFIC NOTE;HOWEVER,GENERAL NOTES ON EACH SHEET SERVICES AS NEEDED FOR CONSTRUCTION;INCLUDING SMOKE SENSOR,DUCT MOUNTED,WITH SAMPLING TUBES. FLUORESCENT STRIPLIGHT-POWER FEED SECTION, FAULT CIRCUIT INTERRUPTER
<br /> SHALL APPLY IN PRACTICE TO ALL ELECTRICAL DRAWINGS. SERVICES TO PORTABLE TRAILERS,POWER TOOLS,AND OTHER �D PHOTOELECTRIC TYPE JON �� FEED THOUGH SECTION,LENGTH AS SHOWN. IDW OUPLEX RECEPTACLE W/WEATHERPROOF COVER —TV— CABLE TV WIRE/CONDUIT
<br /> EQUIPMENT,USED FOR CONSTRUCTION. Q ELECTROMAGNETIC DOOR HOLDER,WALL MOUNTED ® D SPECIAL PURPOSE RECEPTACLE-WALL,CEILING —0/H— AERIAL CONDUCTOR(S)IOVERHEAD LINE
<br /> 0 FLUORESCENT WALL BRACKET-RESTROOM C NEMA CONFIGURATION AS NOTED
<br /> 5. NOT ALL COMPONENTS OF THE ELECTRICAL SYSTEMS ARE 12 FIREMAN'S PHONE JACK,WALL MOUNTED ELECTRICAL EQUIPMENT CONNECTION. �\..
<br /> SHOWN(FOR SIMPLICITY). PROVIDE MATERIALS AND LABOR D. DEMOLITION:SEE OTHER DIVISIONS FOR SCOPE OF DEMOLITION m DIRECTIONAL HID FIXTURE ® PROVIDE#10 AWE NEUTRALS.USE LIQUID-TIGHT FLEX. \"' STROKESI NOT ALL
<br /> WIRING
<br /> QUANTITY S 412 AWEOWNON.CONDUCTORS,
<br /> NECESSARY FOR A COMPLETE AND OPERATIONAL SYSTEM. WORK. REMOVE ELECTRICAL AND COMMUNICATIONS SYSTEMS FIREMAN'S PHONE HAND SET,WALL MOUNTED STR NOTE:INDICATE
<br /> WIRING IS SHOWN ON DRAWING.
<br /> FIREALARM CONNECTION TO COMBINATION FIRE/SMOKE ADA APPROVED WALL SCONCE FLUSH FLOOR BOX DEVICE-DEVICE TYPES PER CONTRACTOR SHALL SCHEDULE OR STANDARD WIRING
<br /> THAT EXIST IN DEMOLISHED AREAS.MAKE SYSTEMS SAFE,SEAL FSD DAMPER ®0 SYMBOLS SHOWN. PRACTICES FOR BRANCH CIRCUITS.
<br /> 6. STAINLESS STEEL HARDWARE: MATERIALS USED FOR THE OPENINGS,AND UPDATED SIGNAGE/SCHEDULES.FINAL ® ® ILLUMINATED EXIT SIGN,SHADED QUADRANT
<br /> MOUNTING AND SUPPORT OF BOXES CABLES,RACEWAYS,LIGHT CONFIGURATION SHALL COMPLY WITH CURRENT CODE. FLAME DETECTOR(FLICKER DETECTOR) INDICATES FACES,ARROW AS SHOWN t GROUND
<br /> PEDESTAL FLOOR DEVICE-DEVICE TYPES PER
<br /> FIXTURES,OUTLETS,AND OTHER ELECTRICAL EQUIPMENT,SHALL a LIGHT(LIGHT,SIGNAL LIGHT,INDICATOR LAMP,STROBE) 0`0 POLE MOUNTED LUMINAIRE ®v SYMBOLS SHOWN. + HOT
<br /> BE 316 STAINLESS STEEL.THIS REQUIREMENT APPLIES TO THE E. COORDINATION WITH FLOAT FABRICATOR:THE CONTRACTOR HEAT DETECTOR,CEILING MOUNTED.RATE OF RISE AND Ogg
<br /> iii iii
<br /> AFOREMENTIONED COMPONENTS WHEN INSTALLED OUTSIDE SHALL COORDINATE ELECTRICAL,EQUIPMENT,CHASE,AND O FIXED TEMPERATURE TYPE,DUN 4 'FOOT'INDICATES WALL MOUNTED LUMINAIRE TWO-PIECE SURFACEMETALRACEWAYWITHRECEPTACLE + GROUND,ISOLATED
<br /> ABOVE GRADE OR WHEN INSTALLED OVER WATER(APPROACH JUNCTION BOX LOCATIONS WITH THE FLOAT MANUFACTURER. (4F HEAT DETECTOR FIXED TEMP.ONLY J AND WITH ALL A NOTED, G T TH AS I AS NDICATED ON THE DRAWINGS NEUTRAL
<br /> PIER,PIER,&FLOATING DOCKS). VERIFY PROVISIONS FOR EQUIPMENT ANCHORING,AND THAT XXX FIXTURE TYPE IDENTIFICATION DESIGNATION
<br /> CHASES AND JUNCTION BOX SIZES/LOCATIONS ARE SUITABLE OR HEAT DETECTOR RATE OF RISE ONLY HOME RUN TO INDICATED DESTINATION,3/4"C.MIN.JON
<br /> 0j-❑ TELEIPOWER POLE,POWER POLE ~
<br /> 7. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. EXACT LOCATIONS FOR THE INSTALLATION OF SPECIFIED ELECTRICAL SYSTEM Plv POST INDICATOR VALVEPIV CONNECTION SCEDVP FOR OWEREANTITYF HEAD)-WAN.UNIT EQUIPMENT(SEE
<br /> ( ) Q SEINING MOUNTED.
<br /> OF HEADS)-WALL,
<br /> OF ELECTRICAL EQUIPMENT ARE APPROXIMATE.CHANGES MADE COMPONENTS USING THE MEANS/METHODS PLANNED FOR CEILING MOUNTED. � COURTESY PHONE WITH ENCLOSURE CONDUIT RUN TURNED UP THROUGH FLOOR OR CEILING.
<br /> BY THE OWNER IN LOCATING ELECTRICAL COMPONENTS OF UP INSTALLATION. FLOAT SHOP DRAWINGS WILL NOT BE APPROVED CORE AS REQUIRED.
<br /> TO TEN FEET HORIZONTALLY IS A PART OF THIS CONTRACT FOR WITHOUT WRITTEN VERIFICATION THAT THE AFOREMENTIONED S REMOTE HEAD
<br /> AT 6"O.C.(LENGTH ASrIND INDICATED).
<br /> RACEWAY WITH RECEPTACLE
<br /> FLOATS.THESE CHANGES MAY BE IMPLEMENTED,AT NO CHARGE COORDINATION HAS TAKEN PLACE AND THAT THE FLOAT SHOP XFF/-y-ZJX POWER PEDESTAL ------ CONDUIT STUBBED OUT AT LOCATION SHOWN.PROVIDED
<br /> TO THE OWNER,UNTIL FINAL APPROVAL OF SHOP DRAWINGS. DRAWINGS HAVE BEEN APPROVED BY THE ELECTRICAL SYSTEM o---0 OPTICAL SENSOR AND REFLECTOR X=30=30A,12DV OUTLET INSULATED BUSHING&PULLROPE.
<br /> INSTALLER. IMPORTANT:COORDINATE CHASE ALIGNMENT IN X=50=50A,120/240V OUTLET TELEPHONE/DATA SLEEVE THROUGH WALL,ABOVE
<br /> X=20GFCI=20A,120V DUPLEX GFCI PROTECTED OUTLET CEILING,EXTEND TO ACCESSIBLE LOCATION BOTH SIDES.
<br /> 8. COORDINATE LOCATIONS OF ELECTRICAL AND COMMUNICATION NEW FLOATS WITH EXISTING CHASES. Y=DOCKONROWID# H TERMINATE WITH BUSHINGS.(1)11/4-CO UON.COORDINATE
<br /> CHASES AND CONDUITS WITH OTHER TRADES.ADJUST Z=SLIP NUMBER/STALL(S)-(1)POWER HEAD EA LOCATIONS WITH CABLE INSTALLER(S)PRIOR TO
<br /> LOCATIONS AS NECESSARY TO AVIOD CONFLICTS. SIGNAL DEVICES SWITCHING CONTROLS NOTE:WDESIGNATES OUTLET PER SLIP.MULTIPLE REFERENCES ROUGH-IN.
<br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION (HIM)INDICATES MULTIPLE OUTLETS PER SLIP. CABLE TRAY
<br /> EQUIPMENT TERMINAL BOARD B'HIGH X WIDTH AS SHOWN, a SINGLE POLE SWITCH(SUPERSCRIPT DENOTES SIMILARLY p O 0 JUNCTION BOXES WALL,CEILING AND FLUSH FLOOR
<br /> FIRE TREATED. 2 MARKED LUMINARIES CONTROLLED TOGETHER) DIAGRAMS C MOUNTED.4'SO.BOX,ION.
<br /> V COMBO TELEPHONE/DATA OUTLET-WALL TWO POLE SWITCH PB SYMBOL DESCRIPTION PULL BOX,MIN SIZE PER NEC.,ION.
<br /> 3
<br /> TELEPHONE OUTLET-WALL THREE WAY SWITCH RAND ALTO OFF FLEXIBLE CONDUIT CONNECTION
<br /> 4
<br /> Q DATA OUTLET-WALL � FOUR WAY SWITCH HAND-F-UT.SWITCH O GROUND ROD CONNECTION
<br /> K
<br /> 0 OC SPEAKER-WALL,CEILING � KEY OPERATED SWITCH � SWITCH ®' GROUND ROD CONNECTION WITH TEST WELL BOX
<br /> DIMMER SWITCH.NUMBER INDICATES WATTAGE RATING.IF + LIGHTNING SYSTEM AIR TERMINAL
<br /> VOLUME CONTROL-WALL NOT SHOWN 11W MINIMUM, OVERLOADS
<br /> F�I� BELL NORMALLY CLOSED CONTACTOR OR RELAY CONTACTS
<br /> SWITCH WITH PILOT(PILOT IS-ON"WHEN SWITCH IS-ON) O UNDERGROUND PULLBOWAULT(P=POWER T=TEUCOM U=UTILITY)
<br /> F
<br /> .I- ��[y BUZZER SWITCH WITH PILOT(PILOT IS'ON"WHEN SWITCH IS'OFF) ❑ ® UNDERGROUND PULLBOMAULT(PLASTIC)
<br /> 'I--� �T NORMALLY OPEN CONTACTOR OR RELAY CONTACTS
<br /> ray CHIME TIMER SWITCH BUS DUCT yp ❑ HANDHOLE
<br /> ©©C SYSTEM CLOCK-WALL,CEILING WEATHERPROOF SWITCH
<br /> SUS BAR
<br /> ®
<br /> dM MOTOR RATED TOGGLE WRHERMAL EMERGENCY CALL BOX P OVERLOAD PROTECTION BATTERY(GENERAL) REFERENCE SYMBOLS
<br /> ® LEAK DETECTOR PC PHOTOCELL CONNECTOR,FEMALE AND MALE RESPECTIVELY SYMBOL DESCRIPTION
<br /> 0 TIME CLOCK O CONTACTOR COIL X� SHEET NOTE REFERENCE(FLAG NOTES)
<br /> WALL MOUNTED DUAL LEVEL SWITCHING OCCUPANCY O RELAYCOIL
<br /> nw� SENSOR XXXX FEEDER NOMINAL AMPACITYS TYPE:SEE FEEDER
<br /> Q TRANSIENT VOLTAGE SURGE SUPPRESSER SCHEDULE.
<br /> EM MUSHROOM HEAD PUSH-BUTTON
<br /> TTON DUTY OIL TIGHT RED
<br /> MUSHROOM HEAD PUSH-BUTTON OX KITCHEN EQUIPMENT REFERENCE
<br /> CURRENT TRANSFORMER
<br /> LCP LIGHTING CONTROL PANEL
<br /> ABBREVIATIONS � POTENTIAL TRANSFORMER X REFER TO DETAIL NOON DRAWING INDICATED NOT ALL
<br /> '� LC LIGHTING CONTROL STATION NORMALLY OPEN PUSH BUTTON DETAIL REFERENCES ARE SHOWN.ALL DETAILS APPLY
<br /> A,AMP AMPERES EF EXHAUSTFAN LCP LIGHT CONTROL PANEL PRI PRIMARY Y-y TO ALL APPLICABLE SITUATIONS,UON.
<br /> AF AMPERE(RATED)FUSES EMT ELECTRICAL METALLIC TUBING MAX MAXIMUM PSE PUGET POWER ENERGY
<br /> w AFF ABOVE FINISHED FLOOR ENCL ENCLOSURE MCA MINIMUM CIRCUIT AMPERES READ REQUIRED NORMALLY CLOSED PUSH BUTTON
<br /> AEG ABOVE FINISHED GRADE EOL END OF LINE MFR MANUFACTURER RNC RIGID NONMETALLIC CONDUIT(PVC) SECURITY SYSTEM DISTRIBUTION&EQUIPMENT PO METER:POWER FACTOR
<br /> AL ALUMINUM(ALLOY) EPA EFFECTIVE PROJECTED AREA MIN MINIMUM RS RAPID START X EL EVATIOWPHOTOTAG:REFERTONUMBER
<br /> ALC AUTOMATED LIGHTING CONTROL EWC ELECTRIC WATER COOLER MISC MISCELLANEOUS SEC SECONDARY SYMBOL DESCRIPTION SYMBOL DESCRIPTION AND SHEET INDICATED
<br /> AS AMPERE(RATED)SWITCH EWH ELECTRIC WATER HEATER MLO MAIN LUGS ONLY SLWO SINGLE LINE WIRING DIAGRAM k© METER:KILOWATT HOUR y-y
<br /> ATS AUTOMATIC TRANSFER SWITCH FA FIRE ALARM MTD MOUNTED SPOT SINGLE POLE DOUBLE THROW BRANCH CIRCUIT PANELBOARDS,SURFACE AND RECESS
<br /> AUTO AUTOMATIC FAA FIRE ALARM ANNUNIATOR MTR MOTOR SPST SINGLE POLE SINGLE THROW CCTV CCTV SECURITY CAMERA ® MOUNTED METER:COMBINATION KILOWATT HOURIKVAR METER
<br /> AUX AUXILIARY PC FOOT CANDLES -N- NEUTRAL(GROUNDED CONDUCTOR) SURF SURFACE \ HATCHSOLID=D=206V
<br /> 0 DOOR POSITION MONITOR SWITCH
<br /> AWG AMERICAN WIRE GAUGE FI-A FULL LOAD AMPERES NC NORMALLY CLOSED SW60 SWITCHBOARD O C HATCHED=2TT/460V O UTILITY CO.APPROVED SOCKET WITH METER INSTALLED
<br /> W %
<br /> BAT BATTERY FL S GR SWITCHGEAR
<br /> EX FLEXIBLE NEC NATIONAL ELECTRICAL CODE SECTION TAG:REFER E DETAIL NO.ON DRAWING.
<br /> BFG BELOW FINISHED GRADE FU FUSE -,NEG NEGATIVE TB TERMINAL BOARD O INFRARED REQUEST TO EXIT DEVICE-WAWCEILING T TRANSFORMER 0 DELTA CONNECTION NOT ALL DETAIL REFERENCES ARE SHOWN.ALL
<br /> TDC TIME DELAY CLOSING MOUNTED. V-V
<br /> C CONDUIT(CIRCULAR RACEWAY) GE N GENERATOR NEMA MANUFACTURE'S
<br /> ASSOC.
<br /> DETAILS APPLY.
<br /> CAB CABINET GFI GROUND FAULT CIRCUIT MAHTLIGHT(USWITCH
<br /> TDO TIME DELAY OPENING SERVICE AND/OR DISTRIBUTION EQUIPMENT GROUND WE CONNECTOR
<br /> y`. CB CIRCUIT BREAKER INTERRUPTER NL NIGHT LIGHT(UNSWITCHEO) TEL TELEPHONE Oj Oj IN M=MAOER STAON-WALL,DESK MOUNTED,
<br /> TVP TYPICAL M M=MASTER STATION III CONNECTION TO GROUND
<br /> U CFM CUBIC FEET PER MINUTE END GROUND NO NOT TO SCOPEN �/ MOTOR CONNECTION.%=HORSEPOWER(WHERE SHOWN)
<br /> U CKT CIRCUIT GRC GALVANIZED RIGID STEEL CONDUIT NTS NOTENSCALE UL UNLERWRITERS LAB
<br /> WISE
<br /> CLG CEILING GRID IN-GROUND OC ON CENTER UON UNLESS OTHERWISE NOTED ❑' PUSH-BUTTON STATION CONNECTION TO DIV.15 FURNISHED VARIABLE FREQUENCY CIRCUIT BREAKER
<br /> O CO CONDUITONLY HP HORSEPOWER OD OUTSIDE DIAMETER UPS VOLTS RRUPTIBLE POWER SUPPLY XX%
<br /> CR CARD READER-WALL MOUNTED ® DRIVE WITH INTEGRAL DISCONNECT DIV.16 TO INSTALL • N XXX=AMPACITY V=POLES
<br /> d CT CURRENT TRANSFORMER HE HERTZ(CYCLES GENGINE SECOND)RINGS OFCI OWNER F TALLED NISHED CONTRACTOR VA VOLT-AMPERES VFD EQUIPMENT
<br /> ,p CU COPPER IDS INSIDE DIAMEENGINEERINGSOCIETY INSTALLED VFD VARIABLE FREQUENCY DRIVE FUSED SWITCH,WITH FUSE AND SWITCH AMPERE RATING
<br /> r OC DIRECT CURRENT ID INSIDE DIAMETER OFOI OWNER FURNISHED,OWNER OL ELECTRIC LOCK DISCONNECT SWITCH,SIZE AS NOTED OR IF NOT SHOWN
<br /> O O DISC DISCONNECT IG ISOLATED GROUND INSTALLED yWV/ W TH OS ELECTRIC STRIKE PIA SIZE PER CONNECTED MOTOR SIZE('MECH'=BV DIVISION 15,TYP). �(�jr CIRCUIT BREAKER,MEDIUM VOLTAGE,DRAWOUT
<br /> O O DIA DIAMETER IN INCANDESCENT OS OCCUPANCY SENSOR W/o WITHOUT
<br /> w N DIV DIVISION INC INTERMEDIATE METAL CONDUIT P POLE Wp WEATHERPROOF © MAGNETIC LOCK �f jr DRAWOUT CIRCUIT BREAKER
<br /> ..� DP DISTRIBUTION PANEL K KEYOPERATED PB PUSH-BUTTON FUSED DISCONNECT SWITCH,SIZE AS NOTED OR IF NOT SHOWN
<br /> DPDT DOUBLE POLE DOUBLE THROW KCM THOUSAND CIRCULAR MILS PENO PENDANT XFMR TRANSFORMER 30A SIZE PER CONNECTED MOTOR SIZE('MECH'=BV DIVISION 15,TYP).
<br /> V DPST DOUBLE POLE SINGLE THROW KO KNOCKOUT PH PHASE ',IN INCHES O ELECTRIC POWER TRANSFER HINGE © GROUND FAULT TRIP UNIT
<br /> or DWG DRAWING KW KILOWATTS PNL PANEL '.FT FEET .,, DISCONNECT W/MAGNETIC MOTOR STARTER(CONTROLLER)OR K KEYINTERLOCK
<br /> �I E.,(E) EXISTING WA KILOVOLT-AMPERES +.POS POSITIVE - PHASE PIA CONTACTOR.SIZE AS NOTED OR IF NOT SHOWN SIZE PER
<br /> CONNECTED MOTOR SIZE.CMECH'=BY DIVISION 15,TYE). VERT DATUM: NAVD 88
<br /> CAPACITOR,POWER FACTOR CORRECTION,SIZE IN WAR
<br /> _= CONV TO MLLW = NAVD88+2.03
<br /> MAGNETIC MOTOR STARTER(bCONTROLLER OR CONTACTOR M G MOTOR-GENERATOR
<br /> HRRSOR POWER [g.A SIZE AS MOTOR NOTED OR
<br /> IF BVDVISION O SIZE CONNECTED N HORZ DATUM: NAD 83/91
<br /> j E N 6 I N E E R S, I N C. IZESOLENOID
<br /> IF SHEET IS LESS THAN 22X34
<br /> PM: ED DAVID, PE TEL: 206.855.4600 REDUCE SCALE ACCORDINGLY
<br /> O PROJECT ENGINEER: SCALE:
<br /> E. DAVID None PORT OF EVERETT °W N ~
<br /> E0.0 w
<br /> Port of DESIGNED BY DATE- CENTRAL MARINA FUEL DOCK
<br /> o� E. DAVID 04/11/2023 CIP NO.
<br /> > DRAWN BY: CHECKED BY:
<br /> EVERETT 2-0-073-01
<br /> a i 16015th Avenue,Suite 1300 J. CAMPBELL E. DAVID PROJECT
<br /> P.O. BOX 538 A 04/11/2023 EJD ISSUED FOR PERMIT REVIEW APPROVED BY: NOTES, LEGEND, ABBREVIATIONS, NO, MR-CM-2023-01
<br /> Seattle,Washington 98101°=
<br /> EVERETT, WA 98206� (206)382-0600 Fax(206)382-0500 W
<br /> o i (425) 259-3164 PROJECT NO.1600120 No. DATE BY REVISIaN No. DATE BY REVISION & LUMINAIRE SCHEDULE SHEET NO. OF
<br /> 2-ti
<br />
|