UTILITY CO.(SNOPUD) COPPER FEEDER SCHEDULE NOTES: COPPER FEEDER SCHEDULE <br /> PAD MTD. PRIMARY <br /> UTILITY CO.XFMR A. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS FEEDER CONDUITS Q® CONDUCTORS PER SET REMARKS <br /> ' SZED BASED ON INSULATION.THE NOTE WI E INDICATES <br /> E TYPES CONDUIT(LISTED <br /> LI SPECIFIED INDSCHEDULE) <br /> IS AS TAG MET SETS RNC PHASE/NEUTRAL GROUND <br /> TYPEUSE 1000.4 3.00" 3 4.00" 4 #400 KCMIL #1/0 - <br /> L NOTED ELSEWHERE IN THE CONTRACT DOCUMENTS. <br /> B. PROMDE NOTED SIZE GROUND CONDUCTOR IN EACH CONDUIT OF FEEDERS CONSISTING OF 800.4 3.00" 3 4.00" 4 #350 KCMIL #1/0 - <br /> MULTIPLE SETS OF CONDUCTORS. 600.4 3.00" 2 4.00" 4 #350 KCMIL #1 - <br /> C. NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. <br /> ___ D. NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75"C TERMINATIONS. 400.4K 2.50" 2 3.00" 5 #3/0 #2 - <br /> IF 7 F- -1 E. ON FEEDERS SHOWN WITH A°.6"SUFFIX,PROVIDE SIX PHASE CONDUCTORS AND ONE GROUND 400.4 2.00" 2 2.50" 4#3/0 #2 - <br /> 1 ww xvae I WIRE IN CODE SIZED CONDUIT.INCLUDE 80%DERATING FACTOR ON PHASE CONDUCTOR SIZE. <br /> L_J L---J F. CONDUIT SIZES AND QUANTITIES ON PLANS TAKE PRECEDENCE OVER THOSE SHOWN IN SCHEDULE 400.3 3.00" 1 4.00" 3 #500 KCMIL #2 - <br /> r - PROVIDE CONDUITS INDICATED IN SCHEDULE FOR FEEDERS NOT SHOWN ON PLANS. 350.4 3.50" 1 4.00" 4#500 KCMIL #2 - <br /> G. PROVIDE CIRCUIT CONDUCTORS AND RACEWAYS FROM PANELBOARD TO EQUIPMENT WHERE FEEDER 350.3 2.50" 1 4.00" 3 #400 KCMIL #2 - <br /> )600/3 TAGS ARE SHOWN ADJACENT TO PANEL SCHEDULES.SEE PLANS FOR EQUIPMENT LOCATIONS. <br /> H. PROVIDE POINT BY POINT CIRCUIT CONDUCTORS AND RACEWAYS AS SHOWN IN BLOCK DIAGRAM(S). 300.4 3.00"1 1 4.00" 1 4 #350 KCMIL #4 - <br /> r------------------L-- ----1------------------------------- 300.3 2.50" 1 3.00" 3 #350 KCMIL #4 <br /> I DISTRIBUTION PANEL'DP1'(E) 600A-480/277V,3P,4W SCHEDULE REMARKS: <br /> 275.4 3.00" 1 4.00" 4 #300 KCMIL #4 - <br /> 0. CABLES NOTE MAY BE USED ONLY WHEN ALLOWED BY CODE AND PROJECT SPECIFlCATIONS. 275.3 2.50" 1 3.00" 3 #300 KCMIL #4 <br /> 1 )40/3 )200/3 )600/3 e) )60/3 20/1 )20/1 )50/3 <br /> O NOT USE. 250.4K 3.00" 1 4.00" 5 #250 KCMIL #4 - <br /> 1 G 250.4 2.50" 1 3.00" 4 #250 KCMIL #4 <br /> O3. REFER TO MCC AND PANEL SCHEDULES FOR FEEDER SIZES TO EQUIPMENT NOTED W1TH THIS TAG. <br /> 250.3 2.50" 1 3.00" 3 #250 KCMIL #4 - <br /> "MET"=EMT,GRC(RIGID),RAC,OR PVC COATED GRC TYPE CONDUITS. 'RNC"=PVC 40,PVC 80 OR 225.4K 2.50" 1 3.00" 5 #4/0 #4 - <br /> ABGERGLASS TYPE CONDUITS ROUTED UNDERGROUND.REFER TO SIZING ON DRAWINGS IF"RNC" <br /> XFMR'T1 (E) xFMR IF' CONDUITS ARE ROUTED ABOVEGROUND.CONDUIT SIZES NOTED ON SINGLE-UNE DIAGRAM OR ON 225.4 2.50" 1 3.00" 1 4 #4/0 #4 - <br /> 45 kVA 45 kVA PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. - <br /> 480-1201208V 480-120/208V 225.3 2.00" 1 2.50" 3 #4/0 #4 <br /> 30,4W 30,4W 0 PROVIDE GROUND WIRE NOTED BELOW IN ALL FEEDERS AND BRANCH CIRCUITS.MINIMUM GROUNDING 200.4K 2.50" 1 3.00" 5 #3/0 #6 - <br /> SHALL BE PER CODE. 200.4 2.00" 1 2.50" 4 #3/0 #6 - <br /> TO(E) TO(E) 125/3 FUEL SYSTEM <br /> DISC'B' SITE SITE ) MAIN DISC. 200.3 2.00" 1 2.50" 3 #3/0 #6 - <br /> F------- LIGHTING LIGHTING 175.4K 2.00" 1 2.50" 5 #2/0 #6 - <br /> I GENERAL NOTES: n5.4 2.00" 1 2.50" 4 #2/0 #6 - <br /> GFq ( 200/3 PANEL 1. COPPER GROUNDS PER CODE. 175.3 1.50" 1 2.00" 3 #2/0 #6 - <br /> RR1' 150.4 1.50" 1 2.00" 4 #1/0 #6 - <br /> UPLAND J 2. AIC RATINGS TO MATCH EXISTING EQUIPMENT. 150.3 1.50" 1 2.00" 1 3 #1/0 #6 - <br /> 125.4 1.50" 1 2.00" 4#1 #6 7 - <br /> 200.3 <br /> 125.3 1.25" 1 2.00" 3 #1 #6 - <br /> 110.4K <br /> FUELSYSTEM 1.50" 1 2.00" 3#2,1 #2/0-N- #6 - <br /> 110.4 1.25" 1 2.00" 4 #2 #6 - <br /> ESPLANADE ELECTRICAL ENCLOSURE <br /> 0 EPO CONTACTOR; 110.3 1.25" 1 2.00" 3 2 - <br /> 10OA-25OV-4P CABLE FEEDER SCHEDULE # "� <br /> 100.4 1.25" 1 2.00" 4 #2 #8 - <br /> TB-B APPROX O.D. <br /> APPROACH PIER F J CABLE TAG- 3C� COND.AWG REMARKS 100.3 1.25" 1 2.00" 3 #2 #8 - <br /> L J PANEL'RR1A' )125/3 150A-208/12OV,3P,4W 20.X MULTI CONDUCTOR TYPE 90.4 1.25" 1 2.00" 4 #4 #8 - <br /> #12 <br /> 0 'SOW CORD gp,3 1.00" 1 1.50" 13 #4 #8 - <br /> 35.X MULTI CONDUCTOR TYPE <br /> FLOATING - <br /> TO B,C 8 20/1 2012 20/1 3013 30/3,D,E, O #10 SOW CORD 80.4 1.25" 1 1.50" 4 #4 #8 <br /> ) ) ) ) ) <br /> F-DOCKS MULTI CONDUCTOR PORTABLE 80.3 1.00" 1 1.50" 3 #4 #8 _ <br /> DOCK(S) (B-DOCK G G G 50.X 0.95"/1.025" #8 POWER CABLE 70.4 1.25" 1 2.00" 4 #4 #8 <br /> G200.a DEMO'D) 75.X 1.11"/1.18" #4 70 1.00" 1 1.50" 3 #4 #8 - <br /> r -1 100.X 1.3"/1.44" #2 60.4 1.00" 1 1.50" 4#6 #10 - <br /> I UNITSUB'BA' 1 1.49"/1.62" #1 O 60.3 0.75" 1 1.W 3 #6, #10 - <br /> 125.X <br /> F 1 1 TO ELECT. 50.4K 1.00" 1 1.50" 3#8, 1 #4-N- #10 - <br /> L CTO EPO ONTROL FMS-1 i50.X 1.63"/1.73" #1/0 <br /> ENCLOSURE 50.4 1.00" 1 1.50" 4 #8 #10 - <br /> (LOCAL) <br /> 1 E11 RECEPT.B 175.X 1.74"/1.90" #2/0 50.3 0.75" 1 1.50" 3 #8 #10 - <br /> -o XXX X L VFD VFD J LIGHT VFD#1 VFD#2 <br /> 200.X 1.88"/2.04" #3/0 <br /> 40.4 0.75" 1 1.00" 4 #8 #10 - <br /> N WIRING PER FMS-1 40.3 0.75" 1 1.00" 3 #8 #10 - <br /> '� DISC-LA 225.X 1.99"/2.16" #4/0 <br /> DISCONNECT r , MFGR REQUIREMENTS 30.4 0.75" 1 1.00" 4 #10 #10 - <br /> N SWITCH-3P,XA <br /> YI 250V,N4X,316 SS M M 250.X 2.29"/2.73" #250MCM 30.2 0.75" 1 1.00" 2 #10 #10 = <br /> TO LEAK DETECTORS 20.4 0.75" 1 1.00" 4 12 12 <br /> XFMR'TBF' 300.X 2.62"/3.10" #350MCM # # <br /> F_ -1 AND LEVEL SENSORS <br /> 0 75 kVA ATTENDANT - <br /> 480-120/208V BUILDING GASOLINE FUEL DIESEL FUEL 20.3 0.75" 1 1.00 3 #12 #12 - <br /> L J 30 4W PUMP STP-1 PUMP STP-2 400.X 2.96"/3.50" #500MCM 15.4 0.75"1 1 1.00" 1 4#12 #12 <br /> 0 15.3 .75"1 1 1.00" 1 3 #12 #12 <br /> ._ •'X'INDICATES NUMBER OF CONDUCTORS PER FEEDER CABLE(EXCLUDING <br /> PANEL 1004 PANEL GROUND CONDUCTORS). <br /> VENDING� 'BF' BFA <br /> SHELTER <br /> U ------L L------J <br /> 0 <br /> 0 <br /> FUEL DOCK I <br /> 0 0 <br /> o <br /> W N <br /> ^I SINGE LINE WIRING DIAGRAM <br /> VERT DATUM: NAVD 88 <br /> CONV TO MLLW = NAVD88+2.03 <br /> HRRBOR POWER HORZ DATUM: NAD 83/91 <br /> j ENG I N EE RS, INC. <br /> IF SHEET IS LESS THAN 22x34 <br /> �- <br /> PM: ED DAVID, PE TEL: 206.855.4600 REDUCE SCALE ACCORDINGLY <br /> O PROJECT ENGINEER: SCALE: <br /> E. DAVID None PORT OF EVERETT °W NO. <br /> E1 .0 ~w <br /> Port of DESIGNED BY DATE- <br /> E. MARINA FUEL DOCK <br /> o� E. DAVID 04/11/2023 cIP No. � <br /> > DRAWN BY: CHECKED BY: <br /> EVERETT 2-0-073-01 <br /> a i 16015th Avenue,Suite 1300 J. CAMPBELL E. DAVID PROJECT <br /> P.O. BOX 538 A 04/11/2023 EJD ISSUED FOR PERMIT REVIEW APPROVED BY: SINGLE LINE WIRING No MR-CM-2023-01 <br /> Seattle,Washington 98101°= <br /> EVERETT, WA 98206� (206)382-0600 Fax(206)382-0500 W <br /> o i (425) 259-3164 PROJECT NO.1600120 No. DATE 6Y REVISION No, DATE 6Y REVISION DIAGRAM SHEET NO. OF <br /> a ti <br />
The URL can be used to link to this page
Your browser does not support the video tag.