My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
>
Address Records
>
SE EVERETT MALL WAY
>
909
>
CRUCIBLE BREWERY
>
909 SE EVERETT MALL WAY CRUCIBLE BREWERY 2025-03-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2025 7:30:51 AM
Creation date
2/10/2025 1:32:42 PM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
909
Tenant Name
CRUCIBLE BREWERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
98
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Programming Cascade Communication <br /> Parameter Settings (Cascade Communication) <br /> Refer to the parameter setting section of this manual for instructions on how to access and change <br /> parameter settings. <br /> Table 24 <br /> Setting # Setting Selection <br /> Description 8 8 C E F <br /> u8 Cascade Secondary Primary <br /> (2-23) <br /> uS Units in Standby <br /> (Cascade) 1 2 3 4 5 6 <br /> u8 Cascade: <br /> Primary: Select the water heater intended to be the Primary water heater for cascade communication. <br /> Set the parameter setting for this water heater to "Primary" (088). <br /> NOTE: Controller will display the set temperature for the system. <br /> Secondary: Factory Default setting for each water heater is set to "Secondary". Parameter adjustment is <br /> only needed on the water heater identified as "Primary". <br /> NOTE: Controller will display"---". <br /> 89 Units in Standby: <br /> Adjust the parameter setting of the primary unit to set the number of water heaters in standby. Standby <br /> units will maintain operation with the water flow control valve in the open position. The remaining water <br /> heaters will maintain the water flow control valve in the closed position. <br /> Setting Secondary ID <br /> After identifying the"Primary"water heater in <br /> the parameter settings, set the Secondary ID <br /> for all remaining water heater in the system by <br /> pressing the "On/Off" button on the controller. <br /> When ID setting is successful, the controller <br /> display will change from "---"to the newly set <br /> ID number. <br /> I'i0 —i7irc -02 -iJ3 <br /> W=tea V avon -r.n aeon anion <br /> Primary water Secondary 01 Secondary 02 Secondary 03 <br /> heater <br /> Figure 55 Identify Secondary ID by <br /> pressing "On/Off' <br /> Rinnai Tankless Water Heater Installation and Operation Manual 53 <br />
The URL can be used to link to this page
Your browser does not support the video tag.