My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2025-04-23
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 3:48:13 PM
Creation date
2/14/2025 8:21:33 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This calculator provided voltage drop calculations in three formats(Point to Point, End of Line, and Load Centering). <br /> Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction <br /> Point to Point Method End of Line Method Load Centering Method <br /> Project Name ZAP ENERGY CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS <br /> Date 6/30/21 <br /> Circuit Number NAC 1 Totals Voltage Totals Voltage Totals Voltage <br /> Area Covered SUITE 100& 101 NOTIFICATION Current Distance Drop Current Distance Drop Current Distance Drop <br /> Nominal System Voltage 24 _ 1.003 345 2.01 1.003 345 3.384 1.003 345 1.692 <br /> Minimum Device Voltage 16 End of Line Voltage 21.99 End of Line Voltage 20.62 End of Line Voltage 22.31 <br /> Total Circuit Current 1.003 Wire Ohm's Percent Drop 8.37% Percent Drop 14.10% Percent Drop 7.05% <br /> Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source <br /> Distance from source to 1st device 50 16 4.89 Standard Wire Resistance in Ohms per 1000 feet. <br /> Wire Gauge for balance of circuit 1 16 4.89 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 <br /> Enter current in amps. Distance _18-14 Awg1=Solid Conductors J 12-10 Awg = Stranded Conductors <br /> rs <br /> .150= 150 ma from Voltage Notes: <br /> Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires(Positive and Negative) <br /> Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then <br /> Device 1 0.223 50 23.51 0.490 2.04% the manufactures listed minimum operating voltage(IE: rated operating voltage 20-32 VDC). <br /> Device 2 0.167 "' 90 22.82 1.177 4.90% <br /> Device 3 0.190 55 22.49 1.507 6.28% Device Manufacturer POTTER Device Manufacturer POTTER <br /> Device 4 0.200 90 22.12 1.879 7.83% Current Current <br /> Device 5 0.223 60 21.99 2.010 8.37% CEILING MOUNT @Rated @Rated <br /> END 21.99 2.010 8.37% Model# Candela Voltage Model# Candela Voltage <br /> END 21.99 2.010 8.37% Strobe _ 15 0.072 <br /> END 21.99 2.010 8.37% Strobe 30 0.101 <br /> END 21.99 2.010 8.37% Strobe 75 0.167 <br /> END 21.99 2.010 8.37% Strobe 95 0.2 <br /> END 21.99 2.010 8.37% Horn -- 0.023 <br /> END 21.99 2.010 8.37% _ <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> END 21.99 2.010 8.37% <br /> Totals 1.003 345 End of Line Voltage 21.99 I 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.