My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2025-04-23
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2025-04-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2025 3:48:13 PM
Creation date
2/14/2025 8:21:33 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
579
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
This calculator provided voltage drop calculations in three formats (Point to Point, End of Line, and Load Centering). <br /> Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction <br /> Point to Point Method End of Line Method Load Centering Method <br /> Project Name ZAP ENERGY CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS <br /> Date 6/30/21 <br /> Circuit Number NAC 2 Totals Voltage _ Totals Voltage Totals _ Voltage <br /> Area Covered NORTH OFFICES NOTIFICATION Current Distance Drop Current Distance Drop Current Distance Drop <br /> Nominal System Voltage 24 0.778 375 2.05 0.778 375 2.853 0.778 375 1.427 <br /> Minimum Device Voltage 16, End of Line Voltage 21.95 End of Line Voltage 21.15 End of Line Voltage 22.57 <br /> Total Circuit Current 0.778 Wire Ohm's Percent Drop 8.53% Percent Drop 11.89% Percent Drop 5.94% <br /> Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source <br /> Distance from source to 1st device 150 16 4.89 Standard Wire Resistance in Ohms per 1000 feet. <br /> Wire Gauge for balance of circuit 1 16 4.89 18=7.77 16=4.89 14=3.07 12=1.98 10=1.24 <br /> Enter current in amps. I Distance 18-14 Awg=Solid Conductors 12-10 Awg=Stranded Conductors <br /> .150= 150 ma from Voltage Notes: r <br /> Device Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires(Positive and Negative) <br /> Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then <br /> Device 1 0.095 150 22.86 1.141 4.76% the manufactures listed minimum operating voltage(IE: rated operating voltage 20-32 VDC). <br /> Device 2 0.190 45 22.56 1.442 6.01% I _ <br /> Device 3 0.124 70 22.22 1.779 7.41% Device Manufacturer POTTER _ Device Manufacturer_ <br /> Device 4 0.072 30 22.11 1.888 7.87% Current I Current <br /> Device 5 0.072 20 22.05 1.946 8.11% CEILING MOUNT @Rated _ _ @Rated <br /> Device 6 0.101 30 21.99 2.012 8.38% Model# Candela Voltage Model# Candela Voltage <br /> Device 7 0.124 30 21.95 2.048 8.53% Strobe 15 0.072 <br /> END 21.95 2.048 8.53% Strobe 30 0.101 <br /> END 21.95 2.048 8.53% Strobe 75 0.167 <br /> END 21.95 2.048 8.53% Strobe 95 0.2 <br /> END 21.95 2.048 8.53% Horn -- 0.023 <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% <br /> END 21.95 2.048 8.53% - <br /> END 21.95 2.048 8.53% <br /> Totals 0.778 375 End of Line Voltage 21.95 <br />
The URL can be used to link to this page
Your browser does not support the video tag.