DN-7112:N•A-14
<br /> NFS-320
<br /> Intelligent Addressable N OT I F l E
<br /> Fire Alarm System by Honeywell
<br /> . Intelligent Fire Alarm Control Pane*
<br /> General
<br /> The NFS-320 intelligent Fire Alarm Control Panel is part of the ,i 13t ;t44itf i•
<br /> ONYX®Series of Fire Alarm Controls from NOTIFIER. (
<br /> In stand-alone or network configurations, ONYX Series products IFS
<br /> meet virtually every application requirement.
<br /> The NFS-320's modular design makes system planning easier.
<br /> The panel can be configured with just a few devices for small build- �`'
<br /> ; ;NOT!FICR
<br /> ing applications,or networked with many devices to protect a large
<br /> campus or a high-rise office block. Simply add additional periph-
<br /> eral equipment to suit the application.Wireless fire protection can
<br /> be added with the SWIFT wireless gateway and devices.
<br /> For installations using NFS-320C,an optional ACM Series annun-
<br /> ciator can be mounted in the same cabinet(up to 48 zones/points,
<br /> order separately;see DN-60085).
<br /> NOTE: Unless called out with a version-specific"A", "C"or"E"at
<br /> the end of the part number, "NFS-320"refers to models NFS-320,
<br /> NFS-320R,NFS-320C,and NFS-320E. NFS-320
<br /> Features • Alarm Verification selection per point,with automatic counter.
<br /> • Certified for seismic applications when used with the appropri- • Presignal/Positive Alarm Sequence(PAS).
<br /> ate seismic mounting kit. • Silence inhibit and Auto Silence timer options.
<br /> • Approved for Marine applications when used with listed corn- • NAC coding functions:
<br /> patible equipment.See DN-60688. —March time.
<br /> • One isolated intelligent Signaling Line Circuit(SLC) Style 4,6 —Temporal.
<br /> or 7.
<br /> • Up to 159 detectors and 159 modules per SLC; 318 devices —California two-stage coding.
<br /> maximum. —Canadian two-stage.
<br /> —Detectors can be any mix of ion,photo,thermal,or multi-sen- —Strobe synchronization.
<br /> sor;wireless detectors are available for use with the FWSG. • Field-programmable on panel or on PC with VeriFire® Tools
<br /> —Modules include addressable pull stations, normally open program check,compare,simulate.
<br /> contact devices, two-wire smoke detectors, notification, or • Full QWERTY keypad.
<br /> relay;wireless modules are available for use with the FWSG. • Battery charger supports 18—200 AH batteries.
<br /> • Optional FWSG Wireless SWIFT Gateway supports wireless • Non-alarm points for lower priority functions.
<br /> SLC devices. • Remote ACK/Signal Silence/System Reset/Drill via monitor
<br /> • Standard 80-character display. modules.
<br /> • Network options: • Automatic time control functions,with holiday exceptions.
<br /> —High-speed network for up to 200 nodes(NFS2-3030, NFS2- • Extensive,built-in transient protection.
<br /> 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX- • Powerful Boolean logic equations.
<br /> Works,NFS-3030,NFS-640,and NCA).
<br /> —Standard network for up to 103 nodes (NFS2-3030, NFS2- FLASHSCAIP INTELLIGENT FEATURES
<br /> 640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX- • Polls up to 318 devices in less than two seconds.
<br /> Works,NCS,NFS-3030,NFS-640,NCA,AFP-200,AFP-300/ • Activates up to 159 outputs in less than five seconds.
<br /> 400, AFP-1010, and AM2020). Up to 54 nodes when DVC- • Multicolor LEDs blink device address during Walk Test.
<br /> EM is used in network paging. • Fully digital,high-precision protocol(U.S.Patent 5,539,389).
<br /> • 6.0 A power supply with four Class A/B built-in Notification • Manual sensitivity adjustment—up to nine levels.
<br /> Appliance Circuits (NAC). Selectable System Sensor, • Pre-alarm ONYX intelligent sensing—up to nine levels.
<br /> Wheelock,or Gentex strobe synchronization. • Day/Night automatic sensitivity adjustment.
<br /> • Built-in Alarm,Trouble,Security,and Supervisory relays. • Sensitivity windows:
<br /> • VeriFire® Tools online or offline programming utility. Upload/
<br /> Download, save, store, check, compare, and simulate panel —Ion—0.5 to 2.5%/foot obscuration.
<br /> databases.Upgrade panel firmware. —Photo—0.5 to 2.35%/foot obscuration.
<br /> • Autoprogramming and Walk Test reports. —Laser(VIEW®)—0.02 to 2.0%/foot obscuration.
<br /> • Multiple central station communication options: —Acclimate®PIusTM—0.5 to 4.0%/foot obscuration.
<br /> —Standard UDACT —IntelliQuad—1.0 to 4.0%/foot obscuration.
<br /> —Internet —IntelliQuadTM PLUS—1.0 to 4.0%/foot obscuration
<br /> —Internet/GSM • Drift compensation(U.S.Patent 5,764,142).
<br /> • 80-character remote annunciators(up to 32). • Degraded mode—in the unlikely event that the NFS-320's pri-
<br /> • EIA-485 annunciators,including custom graphics. mary microprocessor fails, FlashScan detectors revert to
<br /> • Printer interface(80-column and 40-column printers). degraded operation and can activate the control panel's NAC
<br /> • History file with 800-event capacity in nonvolatile memory,plus circuits and alarm relay. Each of the four built-in panel circuits
<br /> separate 200 event alarm-only file. includes a Disable/Enable switch for this feature.
<br /> DN-7112.N•3/24/17—Page 1 of 6
<br />
|