Laserfiche WebLink
This calculator provided voltage drop calculations in three formats(Point to Point, End of Line, and Load Centering). <br /> Make sure that you know what method is accepted by,and the results do not exceed the limits set by the respective jurisdiction <br /> 1 Point to Point Method End of Line Method Load Centering Method <br /> Project Name ZAP ENERGY CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS CIRCUIT IS WITHIN LIMITS <br /> Date 6/30/21 <br /> Circuit Number AUX A Totals Voltage Totals Voltage Totals Voltage <br /> Area Covered STARLINK AND FDU-80 Current Distance Drop Current Distance Drop Current Distance Drop <br /> Nominal System Voltage 24 0.264 185 0.14 0.264 185 0.478 0.264 185 0.239 <br /> Minimum Device Voltage 16 End of Line Voltage 23.86 End of Line Voltage 23.52 End of Line Voltage 23.76 <br /> Total Circuit Current 0.264 Wire _ Ohm's Percent Drop 0.56% Percent Drop 1.99% Percent Drop 1.00% <br /> Gauge Per 1000 End of Line and Load Centering Methods use only the wire guage for the first device to source <br /> Distance from source to 1st device 10 16 - 4.89 Standard Wire Resistance in Ohms per 1000 feet. <br /> Wire Gauge for balance of circuit 16 4.89 18=7.77 16=4.89 14=3.07 12=1.98 10=1. 4 <br /> Enter current in amps. Distance 18-14 Awg=Solid Conductors 12-10 Awg = Stranded Conductors <br /> .150= 150 ma from Volta a Notes: <br /> Device - Device previous At Drop from Percent Wire resistance is doubled in the calculations for two wires(Positive and Negative) <br /> Number Current device Device source Drop The voltage calculated to the last device in any method must not be lower then <br /> Device 1 0.200 10 23.97 0.026 0.11% the manufactures listed minimum operating voltage(IE: rated operating voltage 20-32 VDC). <br /> Device 2 0.064 175 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% Device Manufacturer Device Manufacturer , <br /> END 23.86 0.135 0.56% I Current Current <br /> END 23.86 0.135 0.56% @Rated @Rated <br /> END 23.86 0.135 0.56% Model# Candela Voltage - Model# Candela Voltage <br /> END 23.86 0.135 0.56% STARLINK COMMUNICATOR 0.200 <br /> END 23.86 0.135 0.56% FDU-80 REMOTE DISPLAY 0.064 <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% _ <br /> END 23.86 0.135 0.56% _ <br /> END 23.86 0.135 0.56% _ <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% <br /> END 23.86 0.135 0.56% 7 <br /> END 23.86 0.135 0.56% <br /> Totals 0.264 185 End of Line Voltage 23.86 <br />