Communication Formats UL Listed Receivers <br /> • Ademco Contact ID The chart below shows UL listed receivers compatible with the <br /> • 4+2 Standard UDACT-2. A check in the protocol column indicates the receiver <br /> • SIA supports that protocol. <br /> NOTE:Ademco Contact ID must be used for independent zone <br /> reporting. <br /> 4+2 Ademco <br /> Type Mode Feature Standard Contact <br /> Ademco Contact ID format - only Use Type Mode to identify Receiver 1800/2300 ID SIA <br /> reports to Central Station as: Ademco 685(1) V V <br /> • Fire Alarm •Burglary <br /> • Supervisory •24 hour Non-Burglary Ademco MX8000(2) V V � <br /> • Pull Station •High Temperature Silent Knight 9500(3) <br /> • Heat Detector •Low Temperature <br /> • Waterflow •Low Water Pressure Silent Knight 9800(4) V V V <br /> • Duct Detector •Low Water Level <br /> • Flame Sensor •Pump Failure <br /> FBI CP220FB(5) V V V <br /> • Smoke Zone Osborne Hoffman 2000E(6) <br /> Electrical Specifications Radionics 6600(7) ,i V <br /> Standby current:40 mA. SurGard MLR2(8) <br /> Current while communicating:75 mA. <br /> Maximum current while communicating and with open collector SurGard System III(9) V <br /> output activated: 100 mA. SurGard MLR-2000(10) <br /> Voltage: Regulated 24 volts.Range:21.2 to 28.2 volts. <br /> Agency Listings and Approvals (1)With 685-8 Line Card with Rev 4.4d software <br /> (2)With 124060V206B and 124063 Line Card Rev B <br /> In some cases, certain modules may not be listed by certain (3)With version V2.4 Receiver&126047 Line Card Rev G <br /> approval agencies,or listing may be in process.Consult factory <br /> for latest listing status. (4)With 124077V2.00 Receiver&126047 Line Card Rev M <br /> • UUULC Listed:S635 (5)With software V3.9 <br /> • FM Approved (6)With V.7301 Receiver S/W <br /> • CSFM: 7165-0028:0243 (NFS2-640/320), 7165-0028:0224 (7)With 01.01.03 Receiver S/W&Line Card 01.01.03 <br /> (NFS2-3030) (8)With software V1.86 <br /> • FDNY:COA#6085,COA#6098 (9)With sotware V1.72 <br /> Ordering Information (10)With DSP4016 and V1.6 Line Card <br /> UDACT-2: Universal Digital Alarm Communicator Transmitter. <br /> Includes operating and programming instructions,and mounting <br /> hardware. <br /> MCBL-7:DACT phone cord,7 ft(2.13 m)long(two required). <br /> ABS-8RB:Metal enclosure for externally mounting UDACT-2 up <br /> to 6,000 ft./1828.8 m from host FACP.9.94"H x 4.63"W x 2.50" <br /> D(cm:25.248 H x 11.760 W x 6.350 D). <br /> UBS-1B:Metal enclosure with solid door,Black. <br /> UBS-1BR: Metal enclosure with solid door,Red. <br /> R-1OE:SPDT Form-C relay.Contacts rated for 10 A @ 115 VAC. <br /> Connects to open collector relay driver. <br /> R-2OE:DPDT Two Form-C relays.Contacts rated for 10A @ 115 <br /> VAC.Connects to open collector relay driver. <br /> NOTI•FIRE•NETTM is a trademark and Notifier®is a registered trademark of <br /> FBD-1: Ferrite bead kit.Use for remote mounting only. Honeywell International Inc. <br /> ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use <br /> of this document is strictly prohibited. <br /> ISO 9001 This document is not intended to be used for installation purposes. <br /> We try to keep our product information up-to-date and accurate. <br /> C E R T F tf E We cannot cover all specific applications or anticipate all requirements. <br /> [IMIIEBINC li NAWEFAC11UNi All specifications are subject to change without notice. <br /> QUALITY SYSTEMS Made in the U.S.A. <br /> For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. <br /> www.notifier.com <br /> Page 2 of 2—DN-60686:A1•4/2/12 <br />