Laserfiche WebLink
• e <br /> LATITUDE Product Guide:Latitude'Series Metal Wall Panels <br /> Latitude Series Speciticatiou <br /> SECTION 07410 3. B69-08:Standard Specification for Rolled Zinc. <br /> PREFORMED METAL WALL PANELS 4. B209-07:Specification for Aluminum and Aluminum-Alloy <br /> Sheet and Plate. <br /> 5. D1056-07:Specification for Flexible Cellular Materials- <br /> This specification is applicable for IMETCO LATITUDE concealed clip metal Sponge or Expanded Rubber. <br /> wall panel system. 6. D3575-08:Test Method for Flexible Cellular Materials made <br /> 1.0 GENERAL. from Olefin Polymers. <br /> 7. E283-04:Standard Test Method for Determining Rate of Air <br /> 1.1 DESCRIPTION.**Modify as necessary* Leakage Through Exterior Windows,Curtain Walls,and Doors <br /> A. Work described in this section includes preformed metal wall Under Specified Pressure Differences Across the Specimen. <br /> panel system complete with clips,perimeter and penetration 8. E330-02:Standard Method for Structural Performance of <br /> flashing,closures,gutters,and downspouts. Exterior Windows,Doors,Skylights and Curtain Walls by <br /> Uniform Static Air Pressure Difference. <br /> B. Related work specified elsewhere: 9. E331-00(2009):Standard Test Method for Water Penetration <br /> 1. Structural steel. of Exterior Windows,Skylights,Doors,and Curtain Walls by <br /> 2. Steel joists,girts,and stud walls. Uniform Static Air Pressure Difference. <br /> 3. Metal fabrications. 10. El 886-05:Standard Test Method for Performance of Exterior <br /> 4. Rough carpentry. Windows, Curtain Walls, Doors, and Impact Protective <br /> 5. Insulation. Systems Impacted by Missile(s) and Exposed to Cyclic <br /> 6. Flashing and sheet metal.(Not wall panel related). Pressure Differentials. <br /> 7. Vapor barrier. <br /> 8. Insulation. C. Sheet Metal and Air Conditioning Contractors National Association <br /> (SMACNA): <br /> 1.2 SUBMITTALS. 1. Architectural Sheet Metal Manual,5th edition. <br /> A. Shop drawings: Show wall panel system with flashings and 1.5 QUALITY CRITERIA. <br /> accessories in plan and elevation;sections and details.Include <br /> metal thicknesses and finishes,panel lengths,joining details, A. Engage an experienced metal wall panel contractor(erector)to <br /> anchorage details,flashings and special fabrication provisions install wall panel system who has a minimum of three(3)years <br /> for termination and penetrations. Indicate relationships with experience specializing in the installation of metal wall panel <br /> adjacent and interfacing work.Shop drawings to be prepared by systems. <br /> metal wall panel manufacturer. B. Contractor must be certified by manufacturer specified as supplier <br /> B. Warranty:Provide unexecuted specimen warranty documents for of metal wall panel system and obtain written certification from <br /> each warranty as required in specification section 1.7. manufacturer that installer is approved for installation of specified <br /> system. <br /> C. Samples. <br /> 1. Submit sample of panel section,at least 6"x 6"showing C. Successful contractor must obtain all components of wall panel <br /> seam profile and also a sample of color selected. system from a single manufacturer. Any secondary products <br /> 2. Submit sample of panel clip: that are required which cannot be supplied by the specified <br /> manufacturer must be recommended and approved in writing by <br /> 1.3 DELIVERY,STORAGE,AND HANDLING. primary manufacturer prior to bidding. <br /> A. Inspect materials upon delivery. D. Fabricator/Installer shall submit work experience and evidence of <br /> B. Handle materials to prevent damage. adequate financial responsibility. Architect reserves the right to <br /> inspect fabrication facilities in determining qualifications. <br /> C. Store materials off ground providing for drainage;under cover <br /> providing for air circulation;and protected from any debris. E. Applicable erection tolerances: Maximum variation from true <br /> planes or lines:1/4"in 20'-0";3/8"in 40`-0"or more. <br /> 1.4 REFERENCE STANDARDS, 1.6 DESIGN AND PERFORMANCE CRITERIA. <br /> A. American Iron and Steel Institute(AISI): <br /> 1. SG02-1:2001 Edition of the North American Specification for A. Thermal movement: <br /> the Design of Cold Formed Steel Structural Members. 1. Interface between panel and clip shall provide for unlimited <br /> thermal movement in each direction along the longitudinal <br /> B. American Society for Testing and Materials(ASTM): direction. <br /> 1. A653-09: Specification for Steel Sheet, Zinc-coated 2. Location of metal wall panel rigid connector shall be <br /> (Galvanized)or Zinc-Iron Alloy-Coated(Galvannealed)by designed, per job condition,by the wall panel system <br /> theHot-Dip Process. manufacturer. <br /> 2. A792-09:Specification for Steel Sheet,55%Aluminum-Zinc <br /> Alloy-Coated by the Hot-Dip Process. <br /> www.imetco.com ( (800)646-3826 Page 19 /11 L 7 CO <br />