My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9700 HOLLY DR 2025-07-10
>
Address Records
>
HOLLY DR
>
9700
>
9700 HOLLY DR 2025-07-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2025 7:54:00 AM
Creation date
2/14/2025 1:24:14 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9700
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
143
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LATITUDEProduct Guide:Latitude"Series Metal Wall Panels <br /> B. Uniform Wind Load Capacity. 1. Manufacturers not listed above must submit for approval, <br /> 1. Installed wall panel system shall withstand positive and ten(10)days prior to bid date,the following:Manufacturer's <br /> negative wind pressures complying with the following literature; certification of testing in accordance with <br /> criteria. specification requirements and sections 1.2 and 1.6;sample <br /> a. Design Code:ASCE 7,Method 2 for Components and warranties in accordance with specification section 1.7; <br /> Cladding. installer qualifications in accordance with specification <br /> b. Safety Factor:The panel system shall withstand a"proof section 1.5,and a list of five(5)similar projects in size and <br /> load"equal to 150%of the design wind pressure,as scope of work. <br /> per the ASTM E330 testing standard. 2. No substitutions will be permitted after the bid date of this <br /> c. Category**Select**<I,II,Ill,or IV>Building with an project. <br /> Importance Factor of**Select**<0.77,1.00,or 1.15>. C. Materials. <br /> d. Wind Speed: mph. 1. Panel materials:**Select Material**[24 or 22 or 20]gauge <br /> e. Exposure Category:**Select**<B,C,or D>. G90 galvanized steel,per ASTM A653 or AZ50 Galvalume <br /> f. Maximum Wall Height: feet. steel,per ASTM A792 <br /> g. Minimum Building Width: feet. or[0.032"or 0.040"or 0.050"or 0.063"]aluminum,3105-H14 <br /> h. Roof Pitch: inches per foot. aluminum alloy,per ASTM B209 <br /> Design Wind Pressure: or[0.7 mm or 0.8 mm or 1.0 mm]rolled zinc,Type 710,per <br /> Zone 4-Field of Wall:+ psf and - psf ASTM B69. <br /> Zone 5-Building Corners: + psf and - psf 2. Flashing and flat stock material: Fabricate in profiles <br /> 2. Capacity shall be determined using defined method in indicated on drawings of same material,thickness,and <br /> accordance with ASTM E330. finish as wall panel system,unless indicated otherwise. <br /> C. Air infiltration:The panel system shall be tested in accordance **If Specifying Mill Finish Panels,Delete the Following <br /> with ASTM E283,and meet or exceed the following performance Section <br /> requirements: D. Finish on exposed surfaces. <br /> Pressure Area Leakage Rate 1. Two coat coil applied,baked-on full-strength(70%resin) <br /> 1.57 PSF >0.06 cfm/sq.ft. fluorocarbon coating system(polyvinylidene fluoride,PVF2), <br /> applied by manufacturer's approved applicator. <br /> D. Static air pressure water infiltration:The panel system shall be 2. Coating system shall provide nominal 1.0 mil dry film <br /> tested in accordance with ASTM E331,and meet or exceed the thickness,consisting of primer and color coat. <br /> following performance requirements: **Select Appropriate Color Option Below** <br /> Pressure Result a. Color shall be Imetco's <br /> 5 Gal/Hr per S.F.and Static Air No Leakage b. Color shall be selected from Imetco's Standard Colors. <br /> Pressure of 12.0 psf for 15 minutes c. Color:Custom color selected by architect. <br /> E. Missile Impact Test and Cyclic Wind Pressure Test:The panel d. Color shall be: <br /> system shall be tested in accordance with ASTM El 886 and E1996 e. Zinc panels shall be furnished United Zinc pre- <br /> <or FBC Test Protocols TAS 201 and TAS 203>. weathered"Glacier Gray". <br /> 3. Unexposed surfaces of painted steel or aluminum materials <br /> 1.7 WARRANTIES. shall be baked-on polyester coating with.20-.30 mil total <br /> A. Endorse and forward to owner the following warranties: dry film thickness(TDF). <br /> 1. 10 year limited waterrtight warranty,jointly signed by the 4. Unexposed surface of Zinc panels shall be 5 mil minimum <br /> installer and the manufacturer. plastisol high performance coating system. <br /> 2. Manufacturer's standard 20 year finish warranty covering lf Specifying Painted Panels,Delete the Following Section * <br /> checking,crazing,peeling,chalking,fading,and adhesion. (note:G90 galvanized material is only provided as a painted product) <br /> 3. Installer's 2 year warranty covering wall panel system <br /> installation and watertightness. E. Finish on exposed and unexposed surfaces shall be bare,as <br /> delivered from the mill. <br /> B. Warranties shall commence on date of substantial completion. <br /> F. Characteristics. <br /> 2.0 PRODUCTS. 1. Fabrication: Panels shall be factory formed from specified <br /> 2.1 METAL WALL PANEL SYSTEM. metal. <br /> 2. Profiles shall be as indicated project drawings. <br /> A. Panel shall be Imetco LATITUDE Wall system as manufactured a. The standard profile shall provide ribs at4"on center. <br /> by Innovative Metals Company,Inc.(Imetco),Tucker,Georgia, b. Alternate profile panels shall be used to provide reveals <br /> telephone 1-800-646-3826. of single 8,double 8';or 12"accent bands as shown on <br /> B. Alternate manufacturers are subject to full compliance with project drawings. <br /> specification requirements,and shall be submitted for approval c. Web elements of the ribs shall be[asymmetrical or <br /> as follows: symmetrical]angle. <br /> 3. Panel orientation: [Horizontal or Vertical]. <br /> www.imetco.com I (800)646-3826 Page 20 /M E 7 CO <br />
The URL can be used to link to this page
Your browser does not support the video tag.