My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3332 COLBY AVE CALVARY BAPTIST CHURCH 2025-06-09
>
Address Records
>
COLBY AVE
>
3332
>
CALVARY BAPTIST CHURCH
>
3332 COLBY AVE CALVARY BAPTIST CHURCH 2025-06-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2025 8:24:32 AM
Creation date
2/18/2025 11:59:14 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
3332
Tenant Name
CALVARY BAPTIST CHURCH
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Martin Reimers <br /> Concept Architecture, LLC <br /> Plan Check Number: B2210-002, First Building Review <br /> January 20, 2023 <br /> Architectural <br /> General: <br /> 1. The structural details generally consist of architectural details that have been reproduced on <br /> structural sheets and sealed by the engineer. This is not recommended as it creates redundant <br /> and potentially conflicting information. The architectural sheets should include a note stating <br /> that the structural drawings control for all structural construction. See IBC Section 107.2.1, <br /> RCW 18.43, and structural comments below. <br /> Fire Protection: <br /> 2. Sheet A2.1 includes a Wall Legend that references and conflicts with Detail 5/A0.2. The Wall <br /> Legend appears to specify wood panel structural sheathing that is not specified in the detail. In <br /> addition, the narrative appears to indicate that the GWB occurs between the structural <br /> sheathing and the GWB. The drawings should be revised to clearly indicate the proposed <br /> construction. See IBC Section 107.2.1 and structural comments below. <br /> 3. The building is classified as Type VA construction and required minimum one-hour rated <br /> protection per IBC Table 601. The sections and details do not indicate the beams and columns <br /> are protected, including the elements at the basement level. Details providing the minimum- <br /> required protection should be included. The details should include references to tested <br /> assembly listings per IBC Section 703.2, or be designed per IBC Section 721 or 722. Details <br /> designed per Section 721 should include the appropriate code reference. Details designed per <br /> Section 722 should be substantiated by calculations. <br /> 4. Detail 4/A0.2 references IBC Table 721.1(3)-21-1.1 for the rated assembly. This assembly is for <br /> wood-framed construction, not solid steel joists as indicated in the detail. The assembly <br /> reference should be revised, or a tested assembly should be referenced per IBC Section 703.2. <br /> Egress: <br /> 5. The new entryway doors should specify panic hardware. See IBC Section 1010.1.10. <br /> 6. Additional exit sign should be specified in the new entryway. See IBC Section 1013. <br /> 7. Additional interior and exterior emergency egress lighting should be specified at the entryway <br /> doors. See IBC Sections 1008.3.1 and 1008.3.2(5). <br /> Accessibility: <br /> 8. The new south entry doorway appears intended to include both a latch and closer. The door <br /> should specify a minimum 12-inch clearance on the latch side. See IBC Section 1101.2 and ICC <br /> A117.1-09 Figure 404.2.3.2(b). <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.