Dave Pedersen <br /> Plan Check Number: B2110-028, First Building Review <br /> January 5, 2022 <br /> connectors in contact with preservative-treated wood and fire-retardant-treated <br /> wood shall be in accordance with Section R317.3. <br /> e. Specify roof and floor sheathing and the required nailing. <br /> 2. See Section 3 on Sheet 5. The foundations should be founded a minimum of 18" below grade <br /> for frost protection per EMC Section 16.01.010(J). <br /> 3. The structural drawings include work that has been deferred by the structural engineer. A <br /> statement of deferred submittals shall be added to the Structural General Notes listing work <br /> designated as deferred submittals (Pre-manufactured trusses). The note shall include a <br /> statement requiring the engineer-of-record to review the deferred submittals and verify <br /> conformance with the construction documents. See IBC Sections 107.2.1, 107.3.4, 107.3.4.1, <br /> and 107.4. <br /> 4. Roof Plan shows sheathing cantilevering about 18 inches. A detail or framing should be shown <br /> to support the cantilever. Note the maximum cantilever for roof sheathing beyond the gable <br /> end wall is 9" unless supported by gable overhang framing. See Section R802.5.2.1 <br /> 5. See Section 3 on Sheet 5. Roof assemblies should have uplift resistance in accordance with <br /> Sections R802.11.1.1. Trusses should be attached to supporting wall assemblies by connections <br /> capable of resisting the uplift force. Plans should show the connection between the truss and <br /> wall. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Rakeeb Khan <br /> Residential Plans Examiner <br /> (425)257-7299 <br /> rkhan@everettwa.gov <br /> S:\RKhan\2021\B2110-028_R1.docx <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.