My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20 SW EVERETT MALL WAY EMERALD SPA 2025-04-14
>
Address Records
>
SW EVERETT MALL WAY
>
20
>
EMERALD SPA
>
20 SW EVERETT MALL WAY EMERALD SPA 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 1:41:23 PM
Creation date
2/24/2025 8:17:54 AM
Metadata
Fields
Template:
Address Document
Street Name
SW EVERETT MALL WAY
Street Number
20
Tenant Name
EMERALD SPA
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. James Tan <br /> Plan Check Number: B2108-008, First Building Review <br /> August 16, 2021 <br /> 3. Details should be provided for the construction of the new interior walls. The details should <br /> include top and bottom connections to the supporting construction; where the walls are not <br /> continuous to the roof framing above, struts bracing the top of the walls should be provided. <br /> The walls and connections should be design to resisting a minimum 5 psf load. See IBC <br /> Sections 107.2.1 and 1607.15. <br /> 4. The minimum clear open width for all doors should be 32 inches. See IBC Section 1010.1.1. <br /> 5. The new Break Room does not provide sufficient accessible access, exiting, and turnaround <br /> clearance. The room should be revised. See IBC Section 1101.2, and ICC A117.1-09 Sections <br /> 304 and 404. <br /> 6. The new Break Room is understood to have a new sink and laundry facilities. This should be <br /> shown as new work in the Proposed Floor Plan. See IBC Sections 105.1 and 107.2.1. <br /> 7. The new Break Room includes a new shower. The shower size and access is required to <br /> comply with the accessibility requirements of ICC A117.1-09 Section 608. Details for grab bars <br /> should be included in the construction drawings. See IBC Section 1101.2. <br /> 8. The Restroom is understood to have a new sink cabinet installed. This should be shown as new <br /> work in the Proposed Floor Plan. See IBC Sections 105.1 and 107.2.1. <br /> 9. The Restroom is understood to have a new water heater installed between the sink and toilet. <br /> See IBC Sections 105.1 and 107.2.1. The following comments should be addressed: <br /> a. The water heater should be shown as new work. <br /> b. The water heater encroaches on the accessible clearances for the toilet and cannot be <br /> installed where shown. The water heater should be moved to another location. See IBC <br /> Section 1101.2 and ICC A117.1-09 Section 604. <br /> c. Seismic straps should be specified to restrain the water heater. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> S:\BMartin\2021\B2108-008_R1.docx <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.