Resubmittal Memorandum <br /> February 28, 2022 <br /> 4. The minimum clear open width for all doors should be 32 inches. See IBC <br /> Section 1010.1.1. <br /> Response: Noted.The plans have been updated to show adequate door <br /> openings on all doors.See A1.0. <br /> 5. The new Break Room does not provide sufficient accessible access, exiting, <br /> and turnaround clearance. The room should be revised. See IBC Section <br /> 1101.2, and ICC A117.1-09 Sections 304 and 404. <br /> Response: Noted.The break room layout has been updated to meet the code <br /> compliance.Shower stall is removed and laundry equipments have been <br /> relocated.See A1.0. <br /> 6. The new Break Room is understood to have a new sink and laundry facilities. <br /> This should be shown as new work in the Proposed Floor Plan. See IBC <br /> Sections 105.1 and 107.2.1. <br /> Response:Noted. New works are indicated on the proposed floor plan. See <br /> A1.0. <br /> 7. The new Break Room includes a new shower. The shower size and access is <br /> required to comply with the accessibility requirements of ICC A117.1-09 <br /> Section 608. Details for grab bars should be included in the construction <br /> drawings. See IBC Section 1101.2. <br /> Response:The new shower in the new Break Room is removed to meet code <br /> compliance.See A1.0. <br /> 8. The Restroom is understood to have a new sink cabinet installed. This should <br /> be shown as new work in the Proposed Floor Plan. See IBC Sections 105.1 <br /> and 107.2.1. <br /> Response:The new shower in the new Break Room is removed to meet code <br /> compliance.See A1.0. <br /> 9. The Restroom is understood to have a new water heater installed between <br /> the sink and toilet. See IBC Sections 105.1 and 107.2.1. The following <br /> comments should be addressed: <br /> a. The water heater should be shown as new work. <br /> b. The water heater encroaches on the accessible clearances for the toilet <br /> and cannot be installed where shown. The water heater should be moved <br /> to another location. See IBC Section 1101.2 and ICC A117.1-09 Section <br /> 604. <br /> c. Seismic straps should be specified to restrain the water heater. <br /> Response:The water heater is removed to meet code compliance.See A1.0. <br /> �� 3 <br />