Stephan Collier <br /> Anderson/Collier Architects <br /> Plan Check Number: B2109-026, First Building Review <br /> November 10, 2021 <br /> Architectural <br /> 1. See Sheet 2.0 and A2.1. Bathroom and kitchen exhaust should be specified on the plans. See <br /> Table M1505.4.4(1) for minimum exhaust rates. <br /> 2. Plans should specify safety glazing in Master Bathroom window. R308.4.5 <br /> 3. See Sheet A2.1 and A3.1. East Elevations show existing windows to remain in master closet and <br /> bedroom, but Main Floor Plan does not show windows to remain. R106.1.1 <br /> 4. Plans should specify a minimum 1/2-inch gypsum board covering in enclosed spaces under <br /> stairs. R302.7 <br /> 5. See Sheet A2.1. It appears that a portion of the existing garage is being converted to habitable <br /> space. New habitable space requires to comply with current residential code and energy code <br /> requirements (WSEC R502.1). Plans should show how the space complies with the current <br /> energy code requirements. Note that the energy code requires the floor slab to be insulated. <br /> See WSEC Table 402.1.1 for insulation requirements and options for existing slabs. <br /> 6. Plans should provide details for the stairway, railings, guard rails, and half walls. Reference to <br /> the refer to the IRC is not adequate. R311.7, R312.1 <br /> 7. Continuing with the previous comment, guards and handrails should be designed to resist a <br /> 200-pound load in any direction at any point along the top and guard in-fill components should <br /> be designed to withstand a horizontally applied normal of 50 pounds/foot. See Table 301.5 <br /> 8. See Sheet A2.0 and A2.1. Plans should show smoke detectors (alarms) installed in each <br /> sleeping room, at a point centrally located in the corridor giving access to each separate <br /> sleeping area, and on each floor. R314.3. When more than one smoke alarm is required, they <br /> should be interconnected. <br /> 9. Carbon monoxide alarm should be provided outside of each separate sleeping area in the <br /> immediate vicinity of the bedrooms and on each level of the dwelling. R315.3 <br /> 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.