1200 INDUSTRY ST 2025-03-24
>
Address Records
>
INDUSTRY ST
>
1200
>
1200 INDUSTRY ST 2025-03-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:30:51 AM
Creation date
2/26/2025 11:54:49 AM
Metadata
Fields
Template:
Address Document
Street Name
INDUSTRY ST
Street Number
1200
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Cleats: Galvanized steel, minimum 22 gauge G-90 galvanized steel or one grade thicker <br /> than gravel stop or fascia being anchored whichever is greater. Provide 1/4' kick. Attach <br /> with corrosion resistant No. 10 screws, spaced 12" o.c. <br /> F. Scuppers and Collectors: <br /> 1. Sleeve: Galvanized steel, minimum 24 gauge G-90 galvanized steel, mill finish. <br /> 2. Wall/Deck flange: Galvanized steel, minimum 24 gauge, coated with a minimum of 28 mils <br /> of TPO polymer to match the membrane. <br /> 3. Face Plates: Shall be pre-painted fluoropolymer coated galvanized steel, 24 gauge <br /> minimum. <br /> G. Storm Collars: <br /> 1. For large pipes (greater than 3" diameter), fabricate from 24 gauge galvanized steel. Spot <br /> weld angle brackets to collar(properly spaced) and drill two 3/16" diameter holes on <br /> vertical leg of brackets to secure collar with a nut and bolt assembly (refer to drawings). <br /> 2. For small pipes, fabricate from reinforced flexible membrane. Secure with a stainless steel <br /> draw band. <br /> PART 3 - EXECUTION <br /> 3.01 EXAMINATION <br /> A. Examine substrates and conditions under which sheet metal flashing and trim are to be <br /> installed and verify that Work may properly commence. Do not proceed with installation until <br /> unsatisfactory conditions have been corrected. <br /> B. Verify that surfaces are true and sound enough to retain fasteners as specified. <br /> C. Verify that wood blocking has been provided below membrane for securement of galvanized <br /> flanges. Note, lead flanges do not require wood blocking. <br /> 3.02 GENERAL <br /> A. Unless otherwise indicated, install sheet metal flashing and trim to comply with performance <br /> requirements, manufacturer's installation instructions, as specified in this section. Anchor units <br /> of Work securely in place by methods indicated, providing for thermal expansion of metal units; <br /> conceal fasteners where possible, and set units true to line and level as indicated. Install Work <br /> with laps,joints, and seams that will be permanently watertight and weatherproof. <br /> B. Coordinate with installation of substrates to receive work of this Section and with roofing <br /> system, as required to ensure that each element of the Work performs properly and that <br /> combined elements are waterproof and weather tight. Anchor products securely to structural <br /> substrates to withstand lateral and thermal stresses and inward and outward loading pressures. <br /> C. Metal siding and trim shall be removed and replaced for proper installation of the closure piece. <br /> D. Install exposed sheet metal Work that is without excessive oil canning, buckling, and tool marks <br /> and that is true to line and levels indicated, with exposed edges folded back to form hems. <br /> Install sheet metal flashing and trim to fit substrates and to result in waterproof and weather- <br /> resistant performance. Verify shapes and dimensions of surfaces to be covered before <br /> fabricating sheet metal. <br /> E. Contractor shall provide closures for all sheet metal flashing terminations. The butt ends shall <br /> be fabricated with flanges that conform to the facets of the adjacent wall or substrate. "Dog <br /> ears" or gussets shall be attached and soldered where the metal is cut and bent to change <br /> planes. At concrete walls, the butt plate shall be fastened and sealed along the top edge with <br /> caulking. Butyl sealant tape shall be sandwiched between the wall and the metal flange. <br /> F. Contractor shall round the corners of all flanges that are to be nailed and set over the <br /> completed membrane or flashings. <br /> G. Expansion Provisions: Provide for thermal expansion of exposed sheet metal Work. Space <br /> movement joints at maximum of 10 feet(3 m)with no joints allowed within 24 inches (610 mm) <br /> of corner or intersection. Where lapped or bayonet-type expansion provisions in Work cannot <br /> SEA00511 / Prologis - SEA00511 07 6210 -4 Sheet Metal Flashing and Trim <br /> - FY24- Everett 1 - Capital <br /> Roofing Project <br />