My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11625 AIRPORT RD SONRISE CHRISTIAN CENTER 2025-04-11
>
Address Records
>
AIRPORT RD
>
11625
>
SONRISE CHRISTIAN CENTER
>
11625 AIRPORT RD SONRISE CHRISTIAN CENTER 2025-04-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/11/2025 9:58:33 AM
Creation date
3/3/2025 7:59:47 AM
Metadata
Fields
Template:
Address Document
Street Name
AIRPORT RD
Street Number
11625
Tenant Name
SONRISE CHRISTIAN CENTER
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • <br /> GENERAL STRUCTURAL NOTES: <br /> 1. ALL MATERIALS,WORKMANSHIP,DESIGN,AND CONSTRUCTION SHALL CONFORM TO <br /> THESE NOTES AND THE INTERNATIONAL BUILDING CODE(IBC),2018 EDITION. <br /> 2. DESIGN LOADING CRITERIA: <br /> OCCUPANCY CATEGAORY. . . II <br /> ROOF LIVE LOAD 25 PSF(Is= 1.0) <br /> MECHANICAL UNIT 876 POUNDS <br /> EARTHQUAKE SDS= 1.14 <br /> SITE CLASS C <br /> WIND 98 MPH,EXPOSURE B,KZt= 1.0 <br /> 3. STRUCTURAL CALCULATIONS AND DRAWING SHALL BE USED IN CONJUNCTION <br /> WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR <br /> SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL <br /> NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. <br /> 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS,MEMBER SIZES, <br /> LOCATIONS OF THE UNIT RELATIVE TO THE EXISTING FRAMING,AND CONDITIONS <br /> PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION <br /> SHOWN ON THE DRAWING ARE INTENDED AS GUIDELINES ONLY AND MUST BE <br /> VERIFIED. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS <br /> SHOWN ON THE SKETCHES,OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE <br /> OR SUBSTANDARD QUALITY,NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY <br /> WORK. <br /> 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND <br /> STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN <br /> COMPLETED IN ACCORDANCE WITH THE DRAWINGS. <br /> 6. SHEET METAL SCREWS SHALL BE ITW BUILDEX TEKS SELECTTM SELF-DRILLING <br /> STRUCTURAL FASTENERS OR AN APPROVED EQUAL. <br /> 7. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. <br /> 8. VERIFY THE CONNECTION OF THE EXISTING METAL CURB TO THE WOOD ROOF <br /> STRUCTURE. CONNECTION SHALL BE A MINIMUM OF#12 WOOD SCREWS AT A <br /> MAXIMUM SPACING OF 18"ON-CENTER ON EACH SIDE OF THE UNITS. SUPPLEMENT <br /> THE EXISTING CONDITIONS AS REQUIRED TO MEET THIS REQUIREMENT WITH#12 x 3" <br /> LONG WOOD SCREWS. <br /> 9. CONNECT THE METAL CURB ADAPTER TO THE EXISTING METAL CURB WITH#12 <br /> SHEET METAL SCREWS AT A MAXIMUM OF 18"ON-CENTER ON EACH SIDE OF THE <br /> UNIT. PLACE ONE SCREW AT 6"TO 8"FROM EACH CORNER OF THE UNIT AND THE <br /> REMAINING SCREWS APPROXIMATELY EQUIDISTANT BETWEEN THE CORNERS. <br /> 10. CONNECT THE UNIT TO THE METAL CURB ADAPTER WITH FOUR(4)#12 EQUALLY <br /> SPACED SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT <br /> 6"TO 8"FROM EACH CORNER OF THE UNIT AND THE REMAINING SCREWS rl <br /> APPROXIMATELY EQUIDISTANT BETWEEN THE CORNERS. cu <br /> a <br /> / i � <br />
The URL can be used to link to this page
Your browser does not support the video tag.