Laserfiche WebLink
• • <br /> PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop <br /> mechanical unit. <br /> LOADS: LIVE 25 PSF <br /> DEAD Roofing and re-roof 4.0 <br /> 1/2" plywood sheathing 1.5 <br /> 2x6 @ 24" on-center 1.1 <br /> Insulation 1.0 <br /> MEP 2.0 <br /> Ceiling &Lights 2.0 <br /> Total Dead 12.6 <br /> DEAD + LIVE 37.6 PSF <br /> WIND 98 mph, Exposure B <br /> SEISMIC Latitude 47.892 <br /> Longitude -122.259 <br /> Site Class C WA DNR <br /> SDs= 1.14 <br /> EQUIPMENT <br /> Existing GP-15 New GP-15 <br /> Unit 640 600 <br /> Economizer - 55 <br /> Existing Curb 130 130 <br /> Curb Adapter - 91 <br /> Total 770 pounds 876 pounds <br /> Dimensions 74"x47"x61" high <br /> Moore PROJECT: ENGR: KWM <br /> SONSHINE CHRISTIAN 2 Of <br /> Engineering CENTER GP-1 S DATE: i 0I7I2022 16 <br /> Group SCALE SHEET <br />