My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA C403.8.2 Motor nameplate hp For all applicable HVAC systems with total <br /> fan motor nameplate hp>5hp,indicate fan <br /> motors specified are the smallest available <br /> motor hp size greater than fan bhp,note <br /> exceptions applied <br /> NA C405.8 Fractional hp fan For all fractional hp fan motors(1/12- 1 hp), <br /> motors indicate that motors comply with applicable <br /> WSEC efficiency tables;if motor type is not <br /> listed in an efficiency table,indicate whether <br /> fan has an electronically commutated motor, <br /> has motor rated efficiency of at least 70%,or <br /> exception applied <br /> NA C403.8.3 Fan efficiency For individual fans>5hp,and multiple fans <br /> combined in series or parallel that operate as <br /> the functional equivalent of a single fan with a <br /> combined total motor hp>5hp,indicate in <br /> equipment schedule that rated FEG for all <br /> applicable fans is>_67,or exception applied; <br /> indicate these fans are sized so total efficiency <br /> is within 15%of the fan maximum total <br /> efficiency <br /> C403.8.4 Group R occupancy For all exhaust fans<400 cfm in Group R <br /> exhaust fan efficacy occupancies,indicate in equipment schedule <br /> the fan flow rate and efficacy(cfm/watt),or <br /> exception applied;refer to Table C403.8.4 <br /> NA C403.2.3 Variable flow For fan motors>_7.5 hp,indicate method of <br /> capacity-fans variable flow control(VSD or equivalent <br /> method)in equipment schedule,or exception <br /> applied <br /> NA C403.8.5.1 Fan airflow control For DX air handling units with cooling <br /> capacity>42,000 Btu/h and evaporative and <br /> chilled water air handling units with fan>_ <br /> 0.25 hp,indicate whether system is single <br /> zone or multiple zone and related control <br /> method(cooling capacity controlled in <br /> response to space temperature,space <br /> temperature is controlled by modulating <br /> supply airflow,or both) <br /> NA For mechanical cooling systems(includes DX <br /> and chilled water coils)that control cooling <br /> capacity in response to space temperature- <br /> Provide a minimum of two stages of fan <br /> control;indicate minimum fan speed is< <br /> 66%of full speed drawing<40%of full <br /> speed fan power during periods of low cooling <br /> or ventilation only <br /> Page 5125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.