My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.3.5.2 Heating/cooling Indicate systems and equipment associated <br /> system controls with with the delivery of zone level heating and <br /> DOAS cooling(fans,hydronic pumps,primary air <br /> dampers,etc)are configured to shut off,and <br /> central eqiupment is configured to turn down, <br /> when there is no call for heating or cooling in <br /> the zone they serve <br /> If applying Exception to heating/cooling fans <br /> used for air mixing in the space during <br /> deadband periods,include fan watts per cfm <br /> in equipment schedule <br /> C403.3.5.3 Decoupled DOAS Indicate method of delivery of DOAS supply <br /> supply air air to the occupied space(directly into space, <br /> downstream of terminal heating/cooling <br /> coils);or exception applied <br /> C403.6.1 Multiple zone DOAS For DOAS serving multiple zones,indicate <br /> controls configured to reduce the volume of <br /> outdoor air in each zone independently when <br /> the zone is unoccupied;or exception applied <br /> ADDITIONAL EFFICIENCY CREDITS-DEDICATED OUTSIDE AIR SYSTEMS(DOAS) <br /> C406.6 DOAS For building occupancies not subject to the <br /> requirements of Section C403.3.5,to comply <br /> with this additional efficiency credit,provide <br /> calculations that demonstrate 90%or more of <br /> the total floor area of all occupied, <br /> conditioned spaces are served by a DOAS per <br /> C403.3.5 <br /> C406.7 High performance For all building occupancies,to comply with <br /> DOAS-Energy this additional efficiency credit,demonstrate <br /> recovery compliance with C406.6 <br /> effectiveness and fan <br /> power Indicate energy recovery sensible <br /> effectiveness of all DOAS is>_80% <br /> For each system,indicate that total system fan <br /> power does not exceed 0.5 watts per cfm <br /> FANS AND FAN CONTROLS <br /> NA C403.8.1 Fan power limitation For all HVAC fan systems that provide <br /> heating and/or cooling and all DOAS, <br /> provide system total nameplate hp in <br /> equipment schedules on project plans <br /> NA For all applicable HVAC systems with total <br /> fan motor nameplate hp>5hp,verify fan <br /> system motor hp or bhp complies with fan <br /> power limits per equations in Table <br /> C403.8.1(1) <br /> NA Terminal units installed in conjunction with a <br /> DOAS(hydroninc heat pumps,VRF heat <br /> pumps,chilled/hot water terminal units, <br /> variable volume terminal units)shall be <br /> treated as independent air-handling units for <br /> purposes of fan power calculations <br /> Page 4125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.