My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • 14 of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> ECONOMIZERS <br /> YES C403.5 Air economizer Identify all cooling systems requiring air <br /> required economizer controls in equipment schedules <br /> on plans and in WSEC mechanical equipment <br /> compliance reports <br /> NA Indicate all systems utilizing air economizer <br /> exceptions in WSEC mechanical equipment <br /> compliance report,including those with water- <br /> side economizer in lieu of air economizer; <br /> indicate on plans and in WSEC mechanical <br /> equipment compliance reports all eligible <br /> exception(s)taken and measures to comply <br /> with exception(s) <br /> NA C403.4.1 Integrated Indicate air and water-side economizers are <br /> C403.5.1 economizer operation configured for partial cooling operation even <br /> -air and water where additional mechanical cooling is <br /> required to meet the load <br /> NA For DX air handlers with single or multiple <br /> stages of mechanical cooling;indicate controls <br /> are configured with air economizer as the first <br /> stage of cooling <br /> NA Refer to Requirements List section HVAC <br /> Controls for additional requirements for DX <br /> air handlers <br /> NA C403.5.2 Economizer heating Verify control method of HVAC systems with <br /> system impact-air economizers does not increase building <br /> and water heating energy usage during normal operation <br /> NA C403.5.3.1 Air economizer Indicate modulating outdoor air and return air <br /> capacity dampers are configured to provide up to <br /> 100%outdoor air for cooling <br /> NA C403.5.1 Air economizer Indicate that economizer controls are <br /> C403.5.3.2 controls and configured to provide partial economizer <br /> integrated operation cooling when additional mechanical cooling is <br /> also required to meet the cooling load <br /> NA Indicate that control of economizer dampers <br /> is not based only on mixed air temperature;or <br /> exception applied for systems with cooling <br /> capacity<65,000 Btu/h <br /> NA C403.5.3.3 Air economizer high Indicate high limit shut-off control method <br /> limit controls and required high limit per Table C403.5.3.3 <br /> NA C403.5.3.4 Relief of excess Refer to Requirements List section <br /> outdoor air Ventilation,Exhaust&Energy Recovery <br /> NA Indicate relief air outlets are sized and <br /> configured to relieve excess building air <br /> during air economizer operation to prevent <br /> building over-pressurization <br /> NA Indicate relief air outlet are located to avoid <br /> recirculation into the building <br /> Page 14125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.