My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • i of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.9.2.2 Steam condensate For buildings with on-site steam heating <br /> systems heat recovery systems,indicate condensate water heat <br /> recovery and use of recovered heat <br /> For buildings that use off-site generated steam <br /> where condensate is not returned to the <br /> source,indicate on-site condensate water heat <br /> recovery <br /> C403.9.2.3 Refrigeration For buildings with food service,meat or deli <br /> condenser heat departments that have Z 500,000 Btu/h of <br /> recovery remote refrigeration capacity for coolers/ <br /> freezers,indicate condenser heat recovery and <br /> use of captured energy(service water hearing, <br /> space heating,or dehumidification reheating) <br /> For buildings with>40,000 sf conditioned <br /> floor area and>_ 1,000,000 Btu/h of remote <br /> refrigeration capacity,indicate condenser heat <br /> recovery to pre-heat service water;indicate <br /> remaining recovered heat is applied to space <br /> heating or dehumidification reheating <br /> C403.9.2.4 Heat recovery for For buildings that operate>70 hour per week, <br /> space heating that are not served by a DOAS with energy <br /> recovery,and have>1,500,000 Btu/h of heat <br /> rejection capacity and Z 0.45 cfm per sf of <br /> design minimum supply airflow with reheat, <br /> indicate condenser heat recovery is provided <br /> for space heating that complies with Sections <br /> C403.9.2.4.1 or C403.9.2.4.2 or C403.9.2.4.4 <br /> C403.9.2.4.1 Water to water heat Indicate that 90%or more of the total <br /> C403.9.2.4.4 recovery building space heating and ventilation air <br /> design loads are served by heat energy <br /> rejected from either a heat recovery chiller or <br /> the cooling loop of water to water heat pump <br /> equipment <br /> C403.9.2.4.2 Exhaust heat recovery Indicate that waste heat is recovered from <br /> least 90%of the total building exhaust airflow <br /> such that leaving exhaust air temperature <br /> while in heat recovery mode is 55 deg F dry <br /> bulb;note exhaust air systems eligible for <br /> exception to this requirement <br /> C403.9.2.4.3 Process heat recovery In spaces with 5 watts per sf year-round <br /> cooling loads from lights and equipment, <br /> indicate these spaces are served by water- <br /> cooled equipment configured for heat <br /> recovery <br /> If these spaces are served by economizer(air <br /> or water),indicate automatic controls are <br /> configured to disable economizer operation <br /> while system is in heat recovery mode <br /> MULTIPLE ZONE AIR SYSTEMS <br /> Page 18125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.