My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
>
Address Records
>
RUCKER AVE
>
3006
>
PORT GARDNER BAY WINERY
>
3006 RUCKER AVE PORT GARDNER BAY WINERY 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 10:28:39 AM
Creation date
3/4/2025 12:41:04 PM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3006
Tenant Name
PORT GARDNER BAY WINERY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mechanical Requirements • • 19 of <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2, R3&R4 over 3 stories&all R1 -- Administered by @2024 NEEA,All rights reserved <br /> The following information is necessary to check a mechanical permit application for compliance with the mechanical systems and equipment requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C403.6.1 Air systems serving Identify supply air systems serving multiple <br /> multiple zones zones and the zones they serve on plans; <br /> indicate whether system is VAV and method <br /> of primary air control;or provide supporting <br /> documentation for applied exception to VAV <br /> C403.6.1 VAV air terminal Provide equipment schedules on plans that list <br /> primary supply all VAV air terminals and types(fan-powered <br /> airflow series and parallel air terminals,single duct <br /> and dual duct air terminals,etc) <br /> For each air terminal include:maximum <br /> primary supply airflow rates during zone peak <br /> heating and zone peak cooling;maximum <br /> terminal airflow during reheating,recooling or <br /> mixing;minimum ventilation airflow rate,and <br /> the basis for these values;if IMC or ASHRAE <br /> 62.1 multiple zone equation is the basis for <br /> minimum flow rates,provide this calculation <br /> on plans <br /> C403.6.2 Single duct VAV Indicate single duct terminal units are <br /> terminal units configured to reduce primary supply air <br /> before reheating or recooling <br /> C403.6.3 Dual duct systems- For systems with separate warm air and cool <br /> terminal units air ducts,indicate terminal units are <br /> configured to reduce the flow from one duct <br /> to minimum before mixing with air from the <br /> other duct <br /> C403.6.8C40 VAV system static- Indicate locations of duct static pressure <br /> 3.6.9 pressure sensors and sensors on plans;include at least one sensor <br /> DDC set points per major duct branch;verify controller <br /> setpoint pressure at each sensor is<_ 1.2 inch <br /> w.g. <br /> For systems with zone level DDC,indicate <br /> controls are configured to monitor zone <br /> damper positions and reset static pressure <br /> setpoint based on the zone requiring most <br /> pressure;include control logic that <br /> automatically detects and generates an alarm <br /> if any zone excessively drives reset logic,and <br /> allows building operators to exclude zones <br /> from reset logic <br /> C403.6.4 VAV system supply Indicate controls automatically reset supply <br /> air reset air temperature in response to building loads <br /> or outdoor air temperature;or exception <br /> applied <br /> C403.6.5 Multiple-zone VAV For systems with zone level DDC controls, <br /> system ventilation indicate controls are configured to <br /> optimization controls automatically reduce outdoor airflow in <br /> response to changes in system ventilation <br /> efficiency;or exception applied <br /> Page 19125 <br />
The URL can be used to link to this page
Your browser does not support the video tag.