My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST KAISER PERMANENTE 2025-05-12
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
2930 MAPLE ST KAISER PERMANENTE 2025-05-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2025 8:59:13 AM
Creation date
3/7/2025 2:47:49 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Tenant Name
KAISER PERMANENTE
Imported From Microfiche
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1542
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
KAISER PERMANENTE Site Prep #1 Electrical Service <br />ASC & Clinic (HUB) March 18, 2020 <br />Everett, WA Project No. 19.05002.00 <br />SECTION 23 09 00 - INSTRUMENTATION AND CONTROLS FOR HVAC <br />PART 1-GENERAL <br />1.1 RELATED DOCUMENTS <br />A. Drawings and general provisions of the Contract, including General and Supplementary <br />Conditions and Division 01 Specification Sections, apply to this Section. <br />B. Related Sections include the following: <br />1. Division 01 Section "Commissioning." <br />2. Division 23 Section "Common Mechanical Materials and Methods" <br />3. Division 23 Section "Identification for Mechanical Piping and Equipment' <br />4. Division 23 Section "Fans" <br />5. Division 23 Section "Commissioning of Mechanical Systems: General <br />Requirements." <br />6. Division 26 and 27 "Electrical' <br />1.2 SUMMARY <br />A. This Section includes control equipment for HVAC systems, including control <br />components, wiring and piping for equipment not directly controlled by the DDC system. <br />Control system consists of DDC controllers, sensors, indicators, actuators, final control <br />elements, interface equipment, other apparatus, and accessories connected to <br />controllers to operate systems according to sequences of operation indicated. The <br />control systems shall be designed such that each mechanical system shall be capable of <br />operating under stand-alone mode. System Software shall be updated to the latest <br />version at project completion. <br />B. Electrical equipment, components and accessories shall be U.L. Listed and Labeled. <br />C. DDC system and components shall be BACnet Data Communications Protocol <br />compliant. Controllers, devices and components shall be listed by BACnet Testing <br />Laboratories. <br />D. Emergency Power: DDC controller (with Uninterruptible Power Supply) and components <br />shall be furnished with emergency power if equipment controlled is being installed with <br />emergency power. <br />E. Existing DDC system Siemens will be extended. <br />F. Existing DDC controller shall be replaced or upgraded if not compatible with new DDC <br />system. Existing controllers, firmware, sensors, actuators and components not <br />compatible with new DDC system shall be replaced. Existing DDC system will be <br />required to operate on operating software specified herein. Gateways will not be allowed <br />to communicate with the existing DDC system. <br />G. Unless otherwise indicated, the existing DDC system shall remain operational. <br />Temporary services shall be provided as needed to maintain operations in occupied <br />areas. Disruption in service shall be coordinated and approved by the owner prior to <br />execution of work. <br />INSTRUMENTATION AND CONTROLS FOR HVAC 23 09 00 - 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.